background image

14

104887

UNVENTED NATURAL GAS FIREPLACE

LFP33NR

INSTALLATION

Continued
OPTIONAL WIRELESS HAND-
HELD REMOTE CONTROL
ACCESSORY RM4

Installing Remote Receiver Unit

1.

Disconnect switch wires from the con-
trol valve.

2.

Remove screws and nuts attaching
switchplate. Save screws and nuts to
attach receiver.

3.

Remove switch plate (see Figure 26).
Discard after removing.

4.

Install remote receiver unit onto remote
switch bracket using screws and nuts
removed in step 2. See Figure 27

5.

Route wires through hole in the upper
portion of the switch plate (Figure 27).
Connect wires as shown in Figure 28.
(Black and blue wires are not used for
this application.)

Figure 26 - Switch Plate and Wiring
Harness

Figure 29 - Installing Battery in Remote
Receiver

Screw

Switch Plate

Wires

Figure 27 - Installing Remote Receiver

Installing Batteries in Hand-Held
Remote Control Unit

1.

Remove battery cover on front of re-
mote control unit following direction
of arrow.

 2. Insert two AAA batteries following dia-

gram in battery housing area.

3.

Replace battery cover onto remote con-
trol unit.

Figure 30 - Installing Battery in Hand-
Held Remote Control Unit

AAA
Batteries

Battery
Cover

Remote
Control Unit

Battery
Housing

Figure 28 - Connecting Wires

Red Wire From
Receiver

Valve

White Wire
From Receiver

INSTALLING BATTERIES
FOR RM4

Four AA and two AAA batteries (not in-
cluded) are required to operate this heater
with the wireless hand held remote control
set. AA batteries must be installed in the
receiver and AAA batteries in the hand-held
remote control unit. 

Note:

 Only use alkaline

batteries.

Installing Batteries in Receiver

1.

Locate back of receiver behind the re-
mote switch bracket under the firebox
bottom.

2.

Slide the battery door off of the receiver
in the direction of the arrow on the door.

3.

Insert the four AA batteries according
to Figure 29.

4.

Slide the battery door back into position.

Remote Receiver

Screws

Remote Switch
Bracket

Battery Door

AA Batteries

Remote
Receiver

Ignitor

Nuts

Terminal
Wires

+

+

-

-

-

+

+

+

-

-

+

Содержание Comfort Glow LFP33NR

Страница 1: ...lation adjustment alteration service or maintenance can cause injury orpropertydamage Refertothis manual for correct installation and operational procedures For assistance or additional infor mation c...

Страница 2: ...eplace 7 You must operate this fireplace with the fireplace screen and hood in place Make sure fireplace screen and hood are in place before running fireplace 8 This fireplace is designed to be smoke...

Страница 3: ...e heater front Lift the heater off the bottom tray 2 Locate two screws above top corners of the fireplace screen Remove and discard these screws Lift fireplace screen up and pull out to remove 3 Remov...

Страница 4: ...uate combustion and ventilation air Adjoining rooms are communicating only iftherearedoorlesspassagewaysorventila tion grills between them PRODUCT FEATURES OPERATION This vent free fireplace is clean...

Страница 5: ...tu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount o...

Страница 6: ...s Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connecttheseitemsdirectlytotheoutdoo...

Страница 7: ...es of brass trim together tighten both set screws on the adjusting plate with slotted screwdriver 7 Repeat steps 1 through 6 for other side 8 Tighten trim hanging screws 10 x 6 25 shoulder into holes...

Страница 8: ...1 Assemble cabinet mantel hearth base and trim accessories Assembly instruc tions are included with each accessory 2 When installing blower install a prop erly grounded 120 volt three prong electrical...

Страница 9: ...er use dimen sions shown in Figure 13 for the rough opening The height is 33 which is the same as the wall opening above 2 If using blower install and properly ground GA3555 three prong 120 volt elect...

Страница 10: ...certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to fireplace If pipe is too small undue loss of pressure will occur Mantel Clearances for Built In...

Страница 11: ...for shipping These screws are located near top of screen Discard screws Lift fireplace screen up and pull out to remove 2 Remove screws that attach log base assembly to fireplace see Figure 17 Carefu...

Страница 12: ...or opening main gas valve located on or near gas meter 4 Check all joints of gas supply piping system Apply mixture of liquid soap and water to gas joints Bubbles form ing show a leak 5 Correct all l...

Страница 13: ...cutout on the right of the middle log should fit over the burner see Fig ure 21 Make sure the front of the middle log is resting on the tabs of the grate base and the cutout area is cen tered over the...

Страница 14: ...re mote control unit following direction of arrow 2 Insert twoAAAbatteries following dia gram in battery housing area 3 Replace battery cover onto remote con trol unit Figure 30 Installing Battery in...

Страница 15: ...he battery Place battery into the battery housing 3 Replace battery cover onto remote con trol unit Figure 35 Installing Battery in Hand Held Remote Control Unit Battery Cover 9 Volt Battery Terminal...

Страница 16: ...switch to OFF position 4 Press in and turn control knob clock wise to the OFF position 5 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Fol...

Страница 17: ...HIandLO Slide thee selector switch to the REMOTE po sition Note The burners may light if hand heldremoteONbuttonwasonwhen selector switch was last turned off You can now turn the burners on and off wi...

Страница 18: ...eater and let cool Either remove blockage or replace burner Blocked burner flame holes will create soot CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the p...

Страница 19: ...connect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Repl...

Страница 20: ...requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Observe minimum...

Страница 21: ...ntilate room Stop using odor causing products while fire place is running 2 Locate and correct all leaks see Check ing Gas Connections page 12 1 Open window and or door for ventilation 2 Contact local...

Страница 22: ...ntat1 800 DESALOG 1 800 337 2564 You can also visit DESA International s Technical Service web site at www desatech com SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will...

Страница 23: ...sories Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 4...

Страница 24: ...6F Series Walnut Finished Birch Veneer GMC37U Series Unfinished Birch Veneer Ready to Stain or Paint Space saving corner mantels feature mold ings fluting and medallion Dimensions H xW xD 48 3 4 x 60...

Страница 25: ...LD REMOTE CONTROL RM4 For remote control operation Installation and limited operation instructions included in this manual Extended operation instruc tions included with remote Hand held re mote contr...

Страница 26: ...UNVENTED NATURAL GAS FIREPLACE LFP33NR ILLUSTRATED PARTS BREAKDOWN REMOTE READY MODEL LFP33NR 20 30 7 O F F P I L O T O N H I L O 11 15 29 10 9 7 6 5 8 12 31 17 16 28 18 19 24 14 13 22 23 22 26 27 25...

Страница 27: ...e Injector 1 11 102772 01 Burner 2 12 M11084 38 Screw 8 x 38 2 13 104236 01CK Painted Base Assy 1 14 M12461 26 Screw 10 x 32 6 15 104238 01CK Firebox Bottom 1 16 103284 03 Wiring Harness 1 17 098265 0...

Страница 28: ...28 104887 UNVENTED NATURAL GAS FIREPLACE LFP33NR ILLUSTRATED PARTS BREAKDOWN FIREPLACE LFP33NR 1 2 3 4 15 10 11 9 18 6 17 12 16 16 16 7 8 16 16 5 14 16 13 13 13...

Страница 29: ...Cover 1 6 101784 01 Snap in Magnet 2 7 103411 01CK Louver Hood 1 8 101838 03CK Firebox Wrapper 1 9 103412 01CK Louver Door 1 10 101727 02 Screen Assembly 1 11 101348 01 Firebox Support 2 12 103208 01...

Страница 30: ...ated to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OT...

Отзывы: