background image

18

101827

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including

near the floor. If you smell gas, STOP! Follow “B” in the safety information
at the top of page 17. If you don’t smell gas, go to the next step.

5. Press in control knob.

Note:

 You may be running this heater for the first time after hooking up

to gas supply. If so, you may need to press in control knob for 30 seconds.
This will allow air to bleed from the gas system.

6. Keep control knob pressed in and turn it counterclockwise 

 to the

PILOT/IGN position. This will light pilot.

Note:

 You will hear a loud “click” when the control knob reaches the

PILOT/IGN position.

If pilot does not light

• turn control knob clockwise 

 to the OFF position

• repeat steps 5 and 6

If pilot does not stay lit after several tries

• refer to Troubleshooting, pages 22 through 25
• contact a qualified service person or gas supplier for repairs

Until repairs are made, light pilot with match. To light pilot with match, see
Manual Lighting Procedure
, page 20.

7. Keep control knob pressed in for 10 seconds after lighting pilot. After 10

seconds, release control knob.

•  If control knob does not pop up when released, contact a qualified
service person or gas supplier for repairs.

Note:

 If pilot goes out, repeat steps 3 through 7.

Ignitor Electrode

Figure 17 - Pilot

Pilot Burner

Thermocouple

OPERATING

HEATER

Continued

Содержание Comfort Glow CGP16RA

Страница 1: ...o not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas s...

Страница 2: ...explosion electrical shock and carbon monoxide poisoning DANGER Carbon monoxide poisoning may lead to death Carbon Monoxide Poisoning Early signs of carbon monoxide poisoning resemble the flu with hea...

Страница 3: ...ds fresh outside air ventilation to run properly This heater has an oxygen depletion sensor ODS pilot light safety system The ODS shuts down the heater if not enough fresh air is available See Air for...

Страница 4: ...s or other sources to light heater LOCAL CODES Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of National Fuel Gas Code ANSI Z223 1 also k...

Страница 5: ...t enter your home All fuel burning appliances need fresh air for proper combustion and ventilation Exhaust fans fireplaces clothes dryers and fuel burning appliances draw air from the house to operate...

Страница 6: ...heater ___________________ BTU Hr Gas fireplace logs ___________________ BTU Hr Other gas appliances ___________________ BTU Hr Total ___________________ BTU Hr Example Gas water heater 40 000 BTU Hr...

Страница 7: ...ILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space When ventilat ing to an adjoining unconfined space you must provide two permanent openings...

Страница 8: ...to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grill...

Страница 9: ...nection Purchase the optional A G A design certified manual shutoff valve from your dealer See Accessories page 27 Continued LOCATING HEATER This heater is designed to be mounted on a wall WARNING Mai...

Страница 10: ...tinued CAUTION If you install the heater in a home garage heater pilot and burner must be at least 18 inches above floor locate heater where moving vehicle will not hit it For convenience and efficien...

Страница 11: ...his method provides the strongest hold Insert mounting screws through mounting bracket and into wall studs Attaching to wall anchor This method allows you to attach mounting bracket to hollow walls wa...

Страница 12: ...ket with holes drilled in wall 3 Insert mounting screws through bracket and into wall studs 4 Tighten screws until mounting bracket is firmly fastened to wall studs Attaching to wall anchor method For...

Страница 13: ...talling Bottom Mounting Screws 1 Locate two bottom mounting holes These holes are near bottom on back panel of heater see Figure 11 2 Mark screw locations on wall 3 Remove heater from mounting bracket...

Страница 14: ...not reduce incoming gas pressure heater regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 12 Pointing the vent down protects it from freezing rain...

Страница 15: ...Disconnect heater and its individual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pipe where manual shutoff...

Страница 16: ...rming show a leak 4 Correct all leaks at once PRESSURE TESTING HEATER GAS CONNECTIONS 1 Open manual shutoff valve see Figure 14 2 Open propane LP supply tank valve 3 Make sure control knob of heater i...

Страница 17: ...to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician or gas supplier Force or attempted repa...

Страница 18: ...ud click when the control knob reaches the PILOT IGN position If pilot does not light turn control knob clockwise to the OFF position repeat steps 5 and 6 If pilot does not stay lit after several trie...

Страница 19: ...desired position CAUTION Do not try to adjust heating levels by using the manual shut off valve LOW OFF PILOT IGN MED OFF PILOT IGN HIGH OFF PILOT IGN OFF OFF HIGH MED LOW Control Knob CGP16RA CGP26D...

Страница 20: ...knob TO TURN OFF GAS TO APPLIANCE If pilot flame pattern is incorrect as shown in Figure 20 turn heater off see To Turn Off Gas to Appliance above see Troubleshooting pages 22 through 25 INSPECTING BU...

Страница 21: ...s incorrect as shown in Figure 22 turn heater off see To Turn Off Gas to Appliance page 20 see Troubleshooting pages 22 through 25 Figure 21 Correct Burner Flame Pattern INSPECTING BURNER Continued BU...

Страница 22: ...each use Have heater inspected yearly by a qualified service person Heater may need more frequent cleaning due to excessive lint from carpeting bedding material etc OBSERVED PROBLEM When control knob...

Страница 23: ...D PROBLEM When control knob is pressed in and turned to the PILOT IGN position there is spark at ODS pilot but no ignition ODS pilot lights but flame goes out when control knob is released POSSIBLE CA...

Страница 24: ...en locked positions 1 Residues from manu facturing processes 1 Metal expanding while heating or contracting while cooling REMEDY 1 Clean burner orifice s see Cleaning and Maintenance page 22 or replac...

Страница 25: ...tatement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warn ing statement at top of page 2 Control valve defective 1 Foreign ma...

Страница 26: ...ERVICE HINTS REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Parts Under Warranty Contact authorized dealers of th...

Страница 27: ...ement parts and accessories Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 E Valparaiso IN 46383 All Stat...

Страница 28: ...HEATER EXPLODED VIEW ILLUSTRATED PARTS BREAKDOWN Model CGP16RA 13 15 13 14 ODS PILOT BURNER ASSEMBLY A B C 13 1 13 2 13 3 13 10 13 4 13 5 13 6 13 7 13 8 13 9 13 12 13 13 13 11 1 2 3 11 6 4 8 5 6 7 12...

Страница 29: ...crew 8 x 3 8 2 11 098455 01 Cabinet Assembly 1 12 098324 01 Control Knob 1 13 See Detail Burner Assembly 1 13 1 099218 01 Burner 1 13 2 098508 01 Valve Retainer Nut 1 13 3 099056 01 Injector 3 13 4 09...

Страница 30: ...ATER EXPLODED VIEW ILLUSTRATED PARTS BREAKDOWN Model CGP26D 13 15 13 14 ODS PILOT BURNER ASSEMBLY E D C 13 1 13 2 13 3 13 9 13 4 13 5 13 7 13 6 13 8 13 10 13 12 13 13 13 11 B A 1 2 3 11 6 13 4 8 5 6 7...

Страница 31: ...ew 8 x 3 8 2 11 098456 01 Cabinet Assembly 1 12 098324 01 Control Knob 1 13 See Detail Burner Assembly 1 13 1 099218 02 Burner 1 13 2 098508 01 Valve Retainer Nut 1 13 3 099056 01 Injector 5 13 4 0990...

Страница 32: ...a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and te...