103547

OWNER’S MANUAL

CGP6L

CGP10L

Btu (Variable)

4,400/6,000

5,000/10,000

Type Gas

Propane/LP Only

Propane/LP Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

8" W.C.

8" W.C.

Inlet Gas Pressure (inches of water)

Maximum

14"

14"

Minimum

11"

11"

Dimensions, Inches (H x W x D)

Heater

20 1/2 x 13 1/2 x 5

20 1/2 x 13 1/2 x 5

Carton

25 x 16 11/16 x 7 1/2

25 x 16 11/16 x 7 1/2

Weight (pounds)

Heater

13.5

13.5

Shipping

19

19

Note:

 Use only original replacement parts.

This will protect your warranty coverage for
parts replaced under warranty.

Parts Under Warranty

Contact authorized dealer from whom you
purchased this product. If they cannot sup-
ply original replacement part(s), either con-
tact your nearest Parts Central or call DESA
International’s Technical Service Depart-
ment at 1-800-323-5190 for referral infor-
mation.

When contacting your dealer or DESA In-
ternational, have ready:

• your name

• your address

• model number of your heater

• how heater was malfunctioning

• type of gas used (propane/LP or natural

gas)

• purchase date

Usually, we will ask you to return the defec-
tive part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product.
If they cannot supply original replacement
part(s), either contact your nearest Parts
Central or call DESA International’s Parts
Department at 1-800-972-7879 for referral
information.

When calling DESA International, have
ready:

• model number of your heater

• the replacement part number

REPLACEMENT
PARTS

SPECIFICATIONS

PARTS CENTRALS

These Parts Centrals are privately owned businesses. They have agreed to support our
customer’s needs by providing original replacement parts and accessories.

Baltimore Electric

1348 Dixwell Avenue
Hamden, CT 06514
1-800-397-7553
203-248-7553
Parts Department

Portable Heater Parts

342 N. County Rd.
400 East
Valparaiso, IN 46383
All States
219-462-7441
1-800-362-6951

FBD

1349 Adams Street
Bowling Green, KY 42103
502-846-1199
1-800-654-8534

Four Flags Power
Products

1115 Stateline Road
Niles, MI 49120
616-684-2697
1-800-268-4983
Parts Only

Dayton Hardware

P.O. Box 275
North Dayton Station
Dayton, OH 45404
All States
513-258-3721
OH 1-800-762-3426

Halco Enterprises

208 Carter Drive, Unit 21
West Chester, PA 19382
215-696-2670
1-800-368-0803

LA Porte's Parts & Service

2444 North 5th Street
Hartsville, SC 29550
803-332-0191
Parts Department

Cans Unlimited, Inc.

P.O. Box 645
Taylor, SC 29687
All States
803-879-3009
1-800-845-5301

SERVICE
PUBLICATIONS

You can purchase a service manual from the
address listed on the back page of this
manual. Send a check for $5.00 payable to
DESA International.

Master Service Center

1184 Wilson NW
Walker, MI 49504
616-791-4760
1-800-446-1446

Washer Equipment Co.

1715 Main Street
Kansas City, MO 64108
KS, MO, AR
816-842-3911

East Coast Energy
Products

707 Broadway
W. Long Branch, NJ 07764
908-870-8809
1-800-755-8809

Tarantin Tank Co.

P.O. Box 6129
Freehold, NJ 07728
908-780-9340
1-800-922-0724

Содержание Comfort Glow CGP10L

Страница 1: ...fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice or maintenance can...

Страница 2: ...quiredfeatureforvent free room heaters The ODS pilot shuts off the heater if there is not enough fresh air Piezo Ignition System This heater has a piezo ignitor This system requires no matches batteri...

Страница 3: ...proper venting of vented fuel burning appliances Unusually Tight Construction The air that leaks around doors and win dows may provide enough fresh air for combustion and ventilation However in buildi...

Страница 4: ...the space can support __________ volume of space 50 cu ft Maximum Btu Hr the space can support Example 2560 cu ft volume of space 50 cu ft 51 2 or 51 200 maximum Btu Hr the space can sup port 3 Add th...

Страница 5: ...let Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one...

Страница 6: ...13 page 8 sediment trap tee joint pipe wrench AnA G A design certifiedmanualshutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection The optional A G A design certified ma...

Страница 7: ...igure 8 Tightening Anchors Thin or Thick Wall thick wall shown Solid Wall 1 16 Space Placing Heater On Mounting Screws 1 Locate two keyhole slots on back panel of heater see Figure 9 2 Place large ope...

Страница 8: ...ng rain or sleet Installsedimenttrapinsupplylineasshown in Figure 13 Locate sediment trap where it is within reach for cleaning Locate sedi ment trap where trapped matter is not likely to freeze A sed...

Страница 9: ...ition 4 Check all joints from manual shutoff valve to control valve see Figure 15 Apply mixture of liquid soap and wa ter to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light...

Страница 10: ...s not pop up when released contact a qualified service person or gas supplier for repairs 6 With control knob pressed in push down and release ignitor button This will light pilot The pilot is attache...

Страница 11: ...er off see To Turn Off Gas to Appliance page 10 see Troubleshooting pages 12 through 14 Figure 20 Correct Burner Flame Pattern Model CGP6L will be lower due to lower input rating 1 2 GLASS HEIGHT INCO...

Страница 12: ...trol valve damaged OBSERVED PROBLEM When ignitor button is pressed there is no spark at ODS pilot When ignitor button is pressed there is spark at ODS pilot but no ignition ODS pilot lights but flame...

Страница 13: ...mpany 3 Replace gas regulator 1 Problem will stop after a few hours of operation 1 Turn control knob to LOW position and let warm up for a minute 2 Operate burner until air is removed from line Have g...

Страница 14: ...b is in OFF position Gas odor during combustion Moisture condensationnoticedonwindows POSSIBLE CAUSE 1 Heater burning vapors from paint hair spray glues etc See IMPORTANT statement above 2 Low fuel su...

Страница 15: ...DESA International have ready model number of your heater the replacement part number REPLACEMENT PARTS SPECIFICATIONS PARTS CENTRALS These Parts Centrals are privately owned businesses They have agre...

Страница 16: ...NE LP GAS HEATER 10 000 AND 6 000 BTU HR 10 12 11 1 2 3 4 5 6 7 9 8 GRHpv014C CGP10 10 13 14 15 16 17 18 21 23 24 27 22 26 25 19 20 28 29 HEATER EXPLODED VIEW CGP10L CGP6L 12 2 12 1 ODS PILOT ILLUSTRA...

Страница 17: ...mbly 1 12 1 098514 01 098514 01 Thermocouple 1 12 2 098594 01 098594 01 Ignitor Electrode 1 13 099386 02 099386 02 Burner 1 14 099387 05 099387 05 Pilot Tubing 1 15 098251 08 098251 07 Injector 1 16 0...

Страница 18: ...__________________________________ _______________________________________________________________________________________________ _____________________________________________________________________...

Страница 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 20: ...This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance...

Отзывы: