background image

5

103547

OWNER’S MANUAL

FRESH AIR FOR
COMBUSTION AND
VENTILATION

Continued

Or 

Remove 

Door into 
Adjoining 

Room, 

Option 3

Ventilation Grills 

Into Adjoining Room,

Option 2

12"

12"

Ventilation

Grills

into Adjoining

Room, 

Option 1

Figure 2 - Ventilation Air from Inside Building

Figure 3 - Ventilation Air from Outdoors

Outlet
Air

Ventilated
Attic 

Outlet
Air

Inlet
Air

Inlet Air

Ventilated 

Crawl Space

To 

Crawl

Space

To Attic

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation
grills or ducts. You must provide two per-
manent openings: one within 12" of the
ceiling and one within 12" of the floor.
Connect these items directly to the outdoors
or spaces open to the outdoors. These spaces
include attics and crawl spaces.

IMPORTANT:

 Do not provide openings

for inlet or outlet air into attic if attic has a
thermostat-controlled power vent. Heated
air entering the attic will activate the power
vent.

Содержание Comfort Glow CGP10L

Страница 1: ...fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice or maintenance can...

Страница 2: ...quiredfeatureforvent free room heaters The ODS pilot shuts off the heater if there is not enough fresh air Piezo Ignition System This heater has a piezo ignitor This system requires no matches batteri...

Страница 3: ...proper venting of vented fuel burning appliances Unusually Tight Construction The air that leaks around doors and win dows may provide enough fresh air for combustion and ventilation However in buildi...

Страница 4: ...the space can support __________ volume of space 50 cu ft Maximum Btu Hr the space can support Example 2560 cu ft volume of space 50 cu ft 51 2 or 51 200 maximum Btu Hr the space can sup port 3 Add th...

Страница 5: ...let Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one...

Страница 6: ...13 page 8 sediment trap tee joint pipe wrench AnA G A design certifiedmanualshutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection The optional A G A design certified ma...

Страница 7: ...igure 8 Tightening Anchors Thin or Thick Wall thick wall shown Solid Wall 1 16 Space Placing Heater On Mounting Screws 1 Locate two keyhole slots on back panel of heater see Figure 9 2 Place large ope...

Страница 8: ...ng rain or sleet Installsedimenttrapinsupplylineasshown in Figure 13 Locate sediment trap where it is within reach for cleaning Locate sedi ment trap where trapped matter is not likely to freeze A sed...

Страница 9: ...ition 4 Check all joints from manual shutoff valve to control valve see Figure 15 Apply mixture of liquid soap and wa ter to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light...

Страница 10: ...s not pop up when released contact a qualified service person or gas supplier for repairs 6 With control knob pressed in push down and release ignitor button This will light pilot The pilot is attache...

Страница 11: ...er off see To Turn Off Gas to Appliance page 10 see Troubleshooting pages 12 through 14 Figure 20 Correct Burner Flame Pattern Model CGP6L will be lower due to lower input rating 1 2 GLASS HEIGHT INCO...

Страница 12: ...trol valve damaged OBSERVED PROBLEM When ignitor button is pressed there is no spark at ODS pilot When ignitor button is pressed there is spark at ODS pilot but no ignition ODS pilot lights but flame...

Страница 13: ...mpany 3 Replace gas regulator 1 Problem will stop after a few hours of operation 1 Turn control knob to LOW position and let warm up for a minute 2 Operate burner until air is removed from line Have g...

Страница 14: ...b is in OFF position Gas odor during combustion Moisture condensationnoticedonwindows POSSIBLE CAUSE 1 Heater burning vapors from paint hair spray glues etc See IMPORTANT statement above 2 Low fuel su...

Страница 15: ...DESA International have ready model number of your heater the replacement part number REPLACEMENT PARTS SPECIFICATIONS PARTS CENTRALS These Parts Centrals are privately owned businesses They have agre...

Страница 16: ...NE LP GAS HEATER 10 000 AND 6 000 BTU HR 10 12 11 1 2 3 4 5 6 7 9 8 GRHpv014C CGP10 10 13 14 15 16 17 18 21 23 24 27 22 26 25 19 20 28 29 HEATER EXPLODED VIEW CGP10L CGP6L 12 2 12 1 ODS PILOT ILLUSTRA...

Страница 17: ...mbly 1 12 1 098514 01 098514 01 Thermocouple 1 12 2 098594 01 098594 01 Ignitor Electrode 1 13 099386 02 099386 02 Burner 1 14 099387 05 099387 05 Pilot Tubing 1 15 098251 08 098251 07 Injector 1 16 0...

Страница 18: ...__________________________________ _______________________________________________________________________________________________ _____________________________________________________________________...

Страница 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 20: ...This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance...

Отзывы: