1.

Remove fireplace screen (see Figure 7).

Figure 8 - Removing Log Base from
Fireplace

NOTICE: Shut-off gas supply and
disconnect heater from gas sup-
ply. Contact a qualified service
person to do this.

 CAUTION: Do not pick up log

base assembly by burners. This
could damage burners. Only
handle base by grates.

Screws

Log Base

Flexible Gas Line

2.

If logs are installed, carefully remove
the logs and set aside, noting the prop-
erly mounted location of each.

3.

Remove screws that attach log base as-
sembly to fireplace (do not discard).
Carefully lift up log base assembly and
remove from fireplace, taking care to
pull flexible gas line through the ac-
cess holes (see Figure 8).

Figure 7 - Removing Fireplace Screen

 WARNING: You must operate

this fireplace with the fireplace
screen in place. Make sure fire-
place screen is in place before
running fireplace.

Notches

Screen Mounting Screws

Figure 9 - Mounting Blower to Firebox

Figure 10 - Installing Power Cord,
Mounting Plate, and Selector switch

Figure 11 - Installing Switch and Cover
Assembly

Blower

#8 Screws

Lower Rear
Wall of Firebox

Exhaust
Port

#6 Screws

#10 Screw

Wire
Clips

Selector
Switch

Switch and Cover Assembly

4.

Place the blower against lower rear wall
of firebox outer wrapper with the ex-
haust port directed upward. Align the
holes in top mounting tabs of blower
with holes in wall of wrapper (see Fig-
ure 9). Using two #8 screws provided,
mount blower and tighten screws firmly.

5.

Route terminals end of power cord
through large hole near  top of left floor
support bracket. Make sure to pass the
cord from the outside (left side) towards
the center of firebox (see Figure 10).

6.

Using two #6 screws provided attach
power cord mounting plate to the out-
side face of left floor support bracket.
Drive screws from inside (right side)
of floor support bracket. Attach the
plate so that the power cord is directed

towards rear of firebox (see Figure 10).
Tighten screws firmly.

7.

Remove the three screws (do not dis-
card) and cover plate from center of
firebox wrapper rear wall. Discard this
cover plate.

8.

Mount the supplied thermostatic switch
and cover assembly into firebox wrap-
per wall. Do this by feeding terminal
ends of wire harness into the hole. Al-
low wires to fall to bottom of firebox
cavity (see Figure 11).

9.

Using three screws from step 7, attach
switch and cover assembly to firebox
wrapper rear wall. Tighten screws
firmly (see Figure 11).

10. Mount selector switch to front flange

of left floor support bracket. Align
graphics on switch upright and push
firmly to snap switch into rectangular
hole. Push the selector switch to the off
(middle) position (see Figure 10).

 WARNING: Failure to connect

all wires properly as indicated
may cause electrical short circuit
or personal injury. A qualified
electrician should check that all
connections are made properly.

INSTALLING GA3650T
BLOWER ACCESSORY

(For CGFP28P Model Only)

Содержание Comfort Glow CGFP28N

Страница 1: ...ualified installer service agency or the gas supplier WARNING Improperinstallation adjustment alteration service ormaintenancecancauseinjury orpropertydamage Refertothis manual for correct installatio...

Страница 2: ...on logs 17 Fireplace front and screen becomes very hot when running fireplace Keep children and adults away from hot sur faces to avoid burns or clothing igni tion Fireplace will remain hot for a time...

Страница 3: ...fire box Remove packing 2 Locate two screws above top corners of the fireplace screen Remove and discard these screws Lift fireplace screen up and pull out to remove 3 Remove protective packaging app...

Страница 4: ...er sources to light fireplace THERMOSTAT CONTROL CGFP28NT These fireplaces have a thermostat sensing bulb and a control valve The thermostat controls the heat output and flame height This maintains a...

Страница 5: ...Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of B...

Страница 6: ...m Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directl...

Страница 7: ...in reach of a 120 volt grounded electrical out let orinstallanelectricaloutletwithinreach of the blower power cord For built in in stallation an outlet accessory GA3555 is available see Accessories pa...

Страница 8: ...he holes in top mounting tabs of blower with holes in wall of wrapper see Fig ure 9 Using two 8 screws provided mount blower and tighten screws firmly 5 Route terminals end of power cord through large...

Страница 9: ...urn blower off before continuing Blue Wire Red Wire Green Wire Black Wire White Wire Blue Wire To Switch and Cover Assembly Figure 14 Wiring Diagram If any of the original wire as supplied with the ap...

Страница 10: ...e logs and set aside noting the prop erly mounted location of each 3 Remove screws that attach log base as sembly to fireplace Carefully lift up log base assembly and remove from fire place takingcare...

Страница 11: ...ly line into fire place base area while replacing log base assembly Make sure the entire flexible gas line is in fireplace base area Note If firebrick is installed make sure the back of the firebox bo...

Страница 12: ...ficient with other cabi net mantels and hearth bases Thismaycreateafirehazard See Accessories page 25 for correct mantels and hearth bases Figure 21 Minimum Clearance to Wall and Ceiling 42 16 INSTALL...

Страница 13: ...ocation This installation includes an approved flexible gas line if allowed by local codes after the manual shutoff valve The flexible gas line must be the last item installed on the gas piping See In...

Страница 14: ...NPT tap must be upstream from fireplace see Figure 30 Check your building codes for any special requirements for locating manual shutoff valve to fireplaces Apply pipe joint sealant lightly to male th...

Страница 15: ...les forming show a leak Correct all leaks at once Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PSIG 1 Disconnect fireplace and its individual manual shutoff valve from gas...

Страница 16: ...e see Operating Fire place pages 17 and 18 Thermostat controlled models or pages 18 and 19 Manually controlled models Check all other internal joints for leaks 7 Turn off fireplace see To Turn Off Gas...

Страница 17: ...the safety information in first column 2 Make sure manual shutoff valve is fully open 3 Turn control knob clockwise to the OFF position 4 Wait five 5 minutes to clear out any gas Then smell for gas i...

Страница 18: ...the comfort level you select The ideal comfort setting will vary by householddependingupontheamountof space to be heated the output of the central heating system etc Note Selecting the HI setting will...

Страница 19: ...correctpilotflamepattern Figure 45 shows an incorrect pilot flame pattern Theincorrectpilotflameisnottouch ing the thermocouple This will cause the thermocouple to cool When the thermo couple cools th...

Страница 20: ...hard ware store or home center may carry com pressed air in a can You can use a vacuum cleaner in the blow position If using com pressed air in a can please follow the direc tions on the can If you d...

Страница 21: ...ocouple to cool causing pilot flame to go out This problemcouldbecausedbyoneorboth of the following A Low gas pressure B DirtyorpartiallycloggedODS pilot 6 Thermocouple damaged 7 Control valve damaged...

Страница 22: ...page 20 2 Replace gas regulator 1 Problem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burners until air is removed from line Hav...

Страница 23: ...air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement above 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See...

Страница 24: ...6514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 E Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 Parts Department FBD 1349 Adams St Bo...

Страница 25: ...ve ready model number of your fireplace the replacement part number REPLACEMENT PARTS CABINET MANTEL ACCESSORY WITH FIREPLACE PERIMETER BRASS TRIM GMC11F Series Walnut Finished Hardwood Veneer GMC12U...

Страница 26: ...L GAS FIREPLACE CGFP28N and CGFP28NT ILLUSTRATED PARTS BREAKDOWN LOG BASE ASSEMBLY VARIABLE MANUALLY CONTROLLED MODEL CGFP28N 27 8 9 8 8 19 13 12 8 6 3 4 1 2 7 7 1 7 2 10 18 23 16 11 26 14 6 6 6 6 21...

Страница 27: ...100999 05 Rear Burner Assembly 1 12 102257 08CJ Base Assembly 1 13 098271 06 Ignitor Cable 1 14 103410 01CK Firebox Bottom 1 15 098867 09 Gas Regulator 1 16 101004 04 Front Burner Injector 1 17 102445...

Страница 28: ...ATURAL GAS FIREPLACE CGFP28N and CGFP28NT ILLUSTRATED PARTS BREAKDOWN LOG BASE ASSEMBLY THERMOSTAT CONTROLLED MODEL CGFP28NT 18 6 27 8 9 8 8 19 13 12 3 4 1 2 7 7 1 7 2 10 16 11 26 14 5 6 6 6 6 22 25 2...

Страница 29: ...Pilot Bracket 1 10 101330 05 Front Burner Assembly 1 11 100999 02 Rear Burner Assembly 1 12 102257 08CJ Base Assembly 1 13 098271 06 Ignitor Cable 1 14 103410 01CK Firebox Bottom 1 15 098867 09 Gas R...

Страница 30: ...30 103413 UNVENTED VENT FREE NATURAL GAS FIREPLACE CGFP28N and CGFP28NT ILLUSTRATED PARTS BREAKDOWN FIREPLACE CGFP28N CGFP28NT 1 2 3 4 15 10 11 9 18 6 17 12 16 16 16 7 8 16 16 5 14 16 13 13 13...

Страница 31: ...8 01CK Right Front Side 1 4 102759 01CK Left Front Side 1 5 101514 01CK Cover 1 6 101784 01 Snap in Magnet 2 7 103411 01CK Louver Hood 1 8 101838 03CJ Firebox Wrapper 1 9 103412 01CK Louver Door 1 10...

Страница 32: ...lated to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL O...

Отзывы: