SPECIFICATIONS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low.
If so, contact your local natural gas supplier.
SERVICE HINTS
Btu (Variable)
19,000/26,000
Type Gas
Propane/LP Only
Ignition
Piezo
Manifold Pressure
8" W.C.
Inlet Gas Pressure
(in. of water) *
Maximum
14"
Minimum
11"
Dimensions, Inches (H x W x D)
Fireplace
25
7
/
8
x 27 x 13
3
/
4
Carton
28 x 26
13
/
16
x 16
1
/
2
Weight, pounds
Fireplace
44
1
/
2
lbs.
Shipping
55 lbs.
* For purposes of input adjustment
REPLACEMENT
PARTS
Note:
Use only original replacement parts.
This will protect your warranty coverage
for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s) call DESA International’s Technical
Service Department at 1-866-672-6040 for
referral information.
When calling DESA International, have
ready
• your name
• your address
• model and serial numbers of your fireplace
• how fireplace was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to
the factory.
PARTS NOT UNDER
WARRANTY
Contact authorized dealers of this product
or Parts Central (see page 29). If they can’t
supply original replacement part(s) call
DESA International at 1-866-672-6040 for
referral information.
When calling DESA International, have
ready
• model number of your fireplace
• the replacement part number