TROUBLESHOOTING

 WARNING: Turn off heater

and let cool before servicing. Only
a qualified service person should
service and repair heater.

 CAUTION: Never use a wire,

needle, or similar object to clean
ODS/pilot. This can damage ODS/
pilot unit.

POSSIBLE CAUSE

1. Ignitor electrode not connected to igni-

tor cable

2. Ignitor cable pinched or wet

3. Piezo ignitor nut is loose

4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode positioned wrong

1. Gas supply turned off or equipment

shutoff valve closed

2. Control knob not in PILOT position
3. Control knob not pressed in while in

PILOT position

4. Air in gas lines when installed

5.  Depleted gas supply (propane/LP only)
6. ODS/pilot is clogged

7. Gas regulator setting is not correct

1. Control knob not fully pressed in
2. Control knob not pressed in long enough

3. Equipment shutoff valve not fully open
4. Pilot flame not touching thermocouple,

which allows thermocouple to cool,
causing pilot flame to go out. This prob-
lem could be caused by one or both of
the following:
A) Low gas pressure
B) Dirty or partially clogged ODS/pilot

5. Thermocouple connection loose at con-

trol valve

6. Thermocouple damaged
7. Control valve damaged

REMEDY

1. Reconnect ignitor cable

2. Free ignitor cable if pinched by any

metal or tubing. Keep ignitor cable dry

3. Tighten nut holding piezo ignitor to base

panel of log set. Nut is located behind
base panel

4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace pilot assembly
7. Replace pilot assembly

1. Turn on gas supply or open equipment

shutoff valve

2. Turn control knob to PILOT position
3. Press in control knob while in PILOT

position

4. Continue holding down control knob.

Repeat igniting operation until air is re-
moved

5.  Contact local propane/LP gas company
6. Clean ODS/pilot (see Cleaning and

Maintenance, pages 17 and 18) or re-
place ODS/pilot assembly

7. Replace gas control

1. Press in control knob fully
2. After ODS/pilot lights, keep control

knob pressed in 30 seconds

3. Fully open equipment shutoff valve
4. A) Contact local natural or propane/LP

gas company

B) Clean ODS/pilot (see Cleaning and
Maintenance,  
pages 17 and 18) or re-
place ODS/pilot assembly

5. Hand tighten until snug, then tighten 1/4

turn more

6. Replace pilot assembly
7. Replace control valve

OBSERVED PROBLEM

When ignitor button is pressed, there is no
spark at ODS/pilot

When ignitor button is pressed, there is
spark at ODS/pilot but no ignition

ODS/pilot lights but flame goes out when
control knob is released

Note:

 For additional help, visit DESA

Heating Products’ technical service web
site at 

www.desatech.com

.

Note:

 All troubleshooting items are listed in

order of operation.

TROUBLESHOOTING

Содержание Comfort Glow CF26NT

Страница 1: ...con sult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes Thi...

Страница 2: ...WARNING Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns...

Страница 3: ...e using furniture polish wax carpet cleaner or similar products turn heater off If heated the vapors from these prod ucts may create a white powder residue within burner box or on adjacent walls or fu...

Страница 4: ...ing of vented fuel burning appliances PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code ANSI Z223 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation All space...

Страница 5: ...Sec tion 5 3 or applicable local codes 3 Add the Btu Hr of all fuel burning appliances in the space Vent free heater _____________ Btu Hr Gas water heater _____________ Btu Hr Gas furnace ___________...

Страница 6: ...ir Inlet Air Ventilated Crawl Space To Crawl Space To Attic AIR FOR COMBUSTION AND VENTILATION Continued Figure 2 Ventilation Air from Inside Building Shown with Optional Mantel VENTILATION AIR Ventil...

Страница 7: ...on pages 4 through 6 LOCATING FIREPLACE WARNING Maintain the minimum clearances shown in Figures 4 and 5 If you can provide greater clearances from floor ceiling and joining wall INSTALLATION Continue...

Страница 8: ...nction box until step 6 3 Install gas piping to fireplace location This installation includes an approved flexible gas line if allowed by local codes after the equipment shutoff valve The flexible gas...

Страница 9: ...place 2 screws into vertical sides ASSEMBLING TRIM Trim shipped with mantel 1 Remove packaging from three pieces of trim 2 Locate two adjusting plates with set screws and two shims in the hardware pac...

Страница 10: ...aching Trim to Fireplace AUTO OFF ON Shoulder Screws Assembled Trim INSTALLING BLOWER ASSEMBLY GA3450T INSTALLATION Continued Figure 12 Removing Hood Screws Hood Screen Rod Cover Hex Head Screw Figure...

Страница 11: ...nstalling Blower Assembly GA3450T Cont 10 Install the switch plate on the blower control shield with 2 10 screws provided see Figure 17 Route power cord out of the cabinet by inserting it through the...

Страница 12: ...ation Red Red Fan Switch Auto Off On Blue Blue Thermostat Switch N O Green White Green White On 110 115 V A C Blower Motor Black Off 1 2 3 Auto Blower Bracket Assembly Screw Wire Harness Power Cord Bl...

Страница 13: ...wninFigure21 Locatesedimenttrapwhereitiswithinreachfor cleaning Install in piping system between fuel supply and heater Locate sediment trap where trapped matter is not likely to freeze A sediment tra...

Страница 14: ...ected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Figure 24 2 Pressurizesupplypipingsystembyeitheropeningpropane LPsup ply tank valve f...

Страница 15: ...Failure to position the parts in accor dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury INSTALLING LOGS It...

Страница 16: ...re de partment C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service techni cian or...

Страница 17: ...t or lint Periodically inspect these holes for any blockage and clean if needed Blocked air holes will create soot MAIN BURNER Periodicallyinspectallburnerflameholeswiththeheaterrunning All slotted bu...

Страница 18: ...s technical services web site at www desatech com When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition heater will not produce specified heat propane LP gas supply m...

Страница 19: ...valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is locate...

Страница 20: ...2 Replace gas control 3 Problem will stop after a few hours of operation 1 Refer to Air for Combustion and Venti lation requirements page 4 1 Turn control knob to LO position and let warm up for a mi...

Страница 21: ...king noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY...

Страница 22: ...www desatech com For more information visit www desatech com 22 ILLUSTRATED PARTS BREAKDOWN MODELS CF26PT SHOWN AND CF26NT 12 9 10 11 16 20 18 1 2 4 7 6 19 8 5 13 19 14 19 19 3 15 17 19 ILLUSTRATED PA...

Страница 23: ...099211 01 Screw 10 16 x 2 50 2 6 098867 10 098867 14 Gas Regulator 1 7 102981 01 102981 01 Inlet Tube 1 8 102983 06 111331 08 Outlet Burner Tube 1 9 099056 29 099056 20 Burner Orifice Injector 1 10 1...

Страница 24: ...com For more information visit www desatech com 24 ILLUSTRATED PARTS BREAKDOWN MODELS CF26PT AND CF26NT 5 8 15 17 13 14 11 2 11 1 19 4 12 16 10 6 5 9 1 2 18 7 20 2 20 3 20 1 18 18 16 21 3 18 16 3 21 I...

Страница 25: ...box Top 1 7 Firebox Wrapper 1 8 Bayfront Base 1 9 105421 01 Heat Deflector 1 10 105409 01 Fan Control Shield 1 11 1 105401 01 Screen Rod 1 11 2 105440 01 Screen Assembly 1 12 101386 02 Hinge 2 13 Rive...

Страница 26: ...er Parts 342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 462 7441 1 888 619 7060 Parts Department sales portableheaterparts com techservice portableheaterparts com FBD 1349 Adams St B...

Страница 27: ...ed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 000 to 4...

Страница 28: ...111410 01C For more information visit www desatech com For more information visit www desatech com 28 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 29: ...on the back page of this manual CABINET MANTEL WITH BUILT IN HEARTH BASE Unfinished Hardwood Veneer GMC46U White Lacquer Finish GMC47W Medium Stained Oak Veneer GMC45F For use with fireplace A hardwo...

Страница 30: ...idents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace wil...

Отзывы: