background image

13

107553

OWNER’S MANUAL

For more information, visit www.desatech.com

AU

TO

OFF
ON

3

AU

TO

OFF
ON

INSTALLATION

Continued

AU

TO

OFF
ON

 WARNING: Failure to position

the parts in accordance with these
diagrams or failure to use only
parts specifically approved with
this heater may result in property
damage or personal injury.

INSTALLING LOGS
(CGD3924NRA)

Each log is marked with a number. These
numbers will help you identify the log when
installing. It is very important to install these
logs exactly as instructed. Do not modify
logs. Only use logs supplied with heater.

1.

Locate pegs on the bottom of back log (#1).
Slide these pegs into the holes in the grate
base behind the burner (see Figure 22).

2.

Place the base of the middle log (#2) in
the U-shaped slots of the grate base in
front of the back log. The cutout on the
right of the middle log should fit over the
burner (see Figure 23). Make sure the
front of the middle log is resting on the
tabs of the grate base and the cutout area
is centered over the burner “U” bend.

3.

Locate the recesses on the back of the
front log (#3). Fit these recesses between
the posts of the grate base (see Figure 24).

Figure 22 - Installing Back Log (#1)

Figure 23 - Installing Middle Log (#2)

Figure 24 - Installing Front Log (#3)

Peg

Hole in
Grate Base

Back Log (#1)

Burner

Tab

U-Shaped
Slot

Middle Log (#2)

“U” Bend

Front Log (#3)

Recess

Post

Post

Burner

Cutout

Continued

 CAUTION: After installation

and periodically thereafter, check
to ensure that no flame comes in
contact with any log. With the
heater set to HIGH, check to see
if flames contact any log. If so,
reposition logs according to the
log installation instructions in this
manual. Flames contacting logs
will create soot.

INSTALLING WIRELESS
REMOTE CONTROL
ACCESSORY

Two 9-volt alkaline batteries (not included)
are required to operate this heater with the
wireless hand-held remote control set. One
battery must be installed in the receiver and
one in the hand-held remote control unit.

Note:

 Only use alkaline batteries.

Installing 9-Volt Battery in
Receiver

1.

Locate back of receiver under front
burner of heater.

2.

Locate the battery clip mounted on the
back of the receiver.

3.

Slide a 9-volt battery through the clip.

4.

Attach the terminal wires to the battery.

Installing 9-Volt Battery (Not
Included) in Hand-Held Remote
Control Unit

1.

Remove battery cover on back of re-
mote control unit.

2.

Attach terminal wires to the battery.
Place battery into the battery housing.

3.

Replace battery cover onto remote con-
trol unit.

Figure 19 - Installing Receiver on the
Back of the Base

Figure 20 - Installing Battery in Hand-
Held Remote Control Unit

Battery Clip

9-Volt Battery

Receiver

Terminal
Wires

Battery Cover

9-Volt Battery

Terminal
Wires

Remote
Control
Unit

Battery Housing

Figure 21 - Installing Battery in Hand-Held
Remote Control Unit (CGHRCTA Series)

Remote
Control
Unit

Содержание Comfort Glow CCL3924NR

Страница 1: ...NRA CCL3924NR CCL3930NR 24 and 30 Remote Ready P I L O T O F F O N LO REMOTE OFF HI Also Design Certified As Vented Decorative Appliances When Not Used With Hand Held Thermostat Remote OWNER S OPERATI...

Страница 2: ...ke turn offheaterandcallaqualifiedserviceper son Note Duringinitialoperation slight smokingmayoccurduetologcuringand heater burning manufacturing residues 7 To prevent the creation of soot follow the...

Страница 3: ...ly by grate 2 Remove all protective packaging ap plied to logs and heater for shipment 3 Check all items for any shipping dam age If damaged promptly inform dealer where you bought heater UNPACKING PR...

Страница 4: ...construction is de fined as construction where a walls and ceilings exposed to the outside atmosphere have a con tinuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or le...

Страница 5: ..._____________Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the a...

Страница 6: ...ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors orspacesopentotheoutdoors Thesespaces include a...

Страница 7: ...tateorlocalcodesmay onlyallowoperationofthisappli ance in a vented configuration Check your state or local codes WARNING Make sure the se lector switch is in the OFF posi tion before installing heater...

Страница 8: ...27 Less than 8 Noncombustible material must be extended to at least 8 See Between 8 and 12 above If you cannot extend material you must operate heater with flue damper open Figure 5 Heat Resistant Mat...

Страница 9: ...tallation does notmeettheminimumclearances shown you must do one of the following operate the logs only with the flue damper open raise the mantel to an accept able height remove the mantel 14 Min Com...

Страница 10: ...e Figure 12 page 11 If installing in a brick bottom fire place mark screw locations in mortar joint of bricks 5 Remove heater base from fireplace 6 Drill holes at marked locations using 3 16 masonry d...

Страница 11: ...to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves CAUTION Usepipejointseal ant that is resistant to liquid pe troleum...

Страница 12: ...Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 14 2 Pressurizesupplypipingsystembyeither usingcompressedairoropeningmaingas valve located on or near...

Страница 13: ...ont Log 3 Recess Post Post Burner Cutout Continued CAUTION After installation andperiodicallythereafter check to ensure that no flame comes in contact with any log With the heater set to HIGH check to...

Страница 14: ...g rests firmly between the grate fingers and the grate base see Figure 26 2 Place the base of the middle log 2 in the U shaped slots of the grate base The cutout on the right of the middle log shouldf...

Страница 15: ...he OFF position 5 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety in formation columns 1 and 2 If you don t smell gas...

Страница 16: ...s lit You may shut off the burners and keep the pilot lit by doing one of the following 1 Turn control knob clockwise to the PILOT position 2 UseremotecontrolmanualOFFbutton 3 SetselectorswitchintheOF...

Страница 17: ...ockage or replace burner Blocked burner flame holes will create soot CGHRCTA Series Operation 2b Press the AUTO ON OFF button on the hand held remote control see Figure 36 The lights to the left of th...

Страница 18: ...G BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas This provides a clean burning flame Keep these holes clear of dust dirt...

Страница 19: ...7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut...

Страница 20: ...nti lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Obse...

Страница 21: ...er produces a clicking ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odo...

Страница 22: ...HEATER For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN CGD3924NRA 7 16 16 17 25 16 3 2 1 4 11 21 10 9 12 15 8 19 18 20 6 14 5 13 27 26 26 22 23 24 O F F P I L O T O N H I L O...

Страница 23: ...102772 01 Burner 1 13 099387 12 Pilot Tube Valve to Regulator 1 14 103781 01 Gas Control Valve 1 15 103345 01 Lower Bracket 1 16 M11084 38 Screw 8 x 38 7 17 102775 06CK Painted Base Assembly 1 18 098...

Страница 24: ...or more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN CCL3924NR CCL3930NR 30 18 18 19 27 18 13 23 12 11 14 4 5 1 2 17 10 21 20 22 6 7 3 9 16 8 15 29 28 28 25 26 O F F P I L O T O N H...

Страница 25: ...8 M11084 38 M11084 38 Screw 8 x 38 7 19 102775 06CK 102775 06CK Painted Base Assembly 1 20 098271 07 098271 07 Ignitor Cable 1 21 102445 01 102445 01 Piezo Ignitor 1 22 103587 02CK 103587 02CK Plate S...

Страница 26: ...riginal replacement parts and accessories Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valpar...

Страница 27: ...ur near est Parts Central see page 26 or call DESA International s Sales Department at 1 800 972 7879 for referral information You can also write to the address listed on the back page of this manual...

Страница 28: ...to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES AN...

Отзывы: