UNVENTED NATURAL GAS LOG HEATER
For more information, visit www.desatech.com
INSTALLATION
Continued
INSTALLING HEATER BASE
ASSEMBLY
IMPORTANT:
Make sure the heater burn-
ers are level. If heater is not level, heater will
not work properly.
WARNING: If installing in a
sunken fireplace, special care is
needed. You must raise the fire-
place floor to allow access to
heater control panel. This will in-
sure adequate air flow and guard
against sooting. Raise fireplace
floor with noncombustible mate-
rial. Make sure material is secure.
CAUTION: Do not pick up
heater base assembly by the
burner. This could damage
heater. Only handle base assem-
bly by grates.
WARNING: You must secure
this heater to fireplace floor. If
not, heater will move when you
adjust controls. Moving heater
may cause a gas leak.
Installation Items Needed
• hardware package (provided with heater)
• approved flexible gas hose (not provided)
(if allowed by local codes)
• sealant resistant to propane/LP gas, not
provided
• electric drill with 3/16" masonry drill bit
Note:
Install optional remote receiver and
hand-held remote kit (see Accessories, page
27) before installing gas log heater. See in-
stallation instructions included with the kit.
1.
Apply pipe joint sealant lightly to male
threads of the fitting to be threaded into
gas regulator. Connect approved flex-
ible gas hose to gas regulator of heater
(see Figure 11, page 11).
2.
Locate masonry screws in hardware
package.
3.
Position heater base assembly in fire-
place.
4.
Mark screw locations through holes in
mounting flanges (see Figure 12, page
11). If installing in a brick-bottom fire-
place, mark screw locations in mortar
joint of bricks.
5.
Remove heater base from fireplace.
6.
Drill holes at marked locations using
3/16" masonry drill bit.
CAUTION: Do not remove the
metal data plates attached to the
heater base assembly. The data
plates contain important warranty
information.
INSTALLING DAMPER
CLAMP ACCESSORY FOR
VENTED OPERATION
Note:
When used as a vented heater, appli-
ance must be installed only in a solid-fuel
burning fireplace with a working flue and
constructed of noncombustible material.
If your heater is a manually-controlled
model, you may use this heater as a vented
product. There are three reasons for operat-
ing your heater in the vented mode.
1.
The fireplace does not meet the clear-
ance to combustibles requirements for
vent-free operation.
2.
State or local codes do not permit vent-
free operation.
3.
You prefer vented operation.
If reasons number 1 or 2 above apply to you,
you must permanently open chimney flue
damper. You must install the damper clamp
accessory (to order, see Accessories, page
27). This will insure vented operation (see
Figure 10). The damper clamp will keep
damper open. Installation instructions are
included with clamp accessory.
See chart below for minimum permanent
flue opening you must provide. Attach
damper clamp so the minimum permanent
flue opening will be maintained at all times.
Figure 10 - Attaching Damper Clamp
Damper
Clamp
Damper
Chimney
Minimum Permanent
Height (ft.) Flue Opening (sq. ins.)
6' to 15'
39 sq. inches
15' to 30'
29 sq. inches
Area of Various Standard
Round Flues
Diameter (ins.)
Area (sq. ins.)
5"
20 sq. inches
6"
29 sq. inches
7"
39 sq. inches
8"
51 sq. inches
Damper
Damper
Clamp
Damper
Manufactured Fireplace
Masonry Fireplace