107434-01C
For more information, visit www.desatech.com
For more information, visit www.desatech.com
14
Figure 22 - Pilot
6.
With control knob pressed in, press and release ignitor but-
ton. This will light pilot. The pilot is attached to the front
burner. If needed, keep pressing ignitor button until pilot lights.
Note:
If pilot does not stay lit, contact a qualified service
person or gas supplier for repairs. Until repairs are made,
light pilot with match. To light pilot with match, see Manual
Lighting Procedure.
7.
Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.
• If control knob does not pop out when released, contact a
qualified service person or gas supplier for repairs.
Note:
If pilot goes out, repeat steps 3 through 7. This heater
has a safety interlock system. Wait one (1) minute for sys-
tem to reset before lighting pilot again.
8.
Turn control knob counterclockwise
C-clockwise
to desired heat-
ing level. The burners should light. Set control knob to any
heat level between HI and LO.
TO TURN OFF GAS TO
APPLIANCE
1.
Follow steps 1 through 5 under Lighting Instructions, page 13.
2.
Depress control knob and light pilot with match.
3.
Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob. Now follow
step 8 in column 1.
Shutting Off Heater
Turn control knob clockwise
Clockwise
to the OFF position.
Shutting Off Burners Only (pilot stays lit)
Turn control knob clockwise
Clockwise
to the PILOT position.
THERMOSTAT CONTROL
OPERATION
The thermostat control knob can be set to any comfort level between
Hi and Lo. The thermostat will gradually modulate the heat output
and flame height from higher to lower settings, or pilot, in order to
maintain the comfort level you select. The ideal comfort setting will
vary by household depending upon the amount of space to be heated,
the output of the central heating system, etc.
Note:
Selecting the Hi setting with the control knob will cause
the burners to remain fully on, without modulating down in
most cases.
MANUAL LIGHTING
PROCEDURE
Thermocouple
Pilot Burner
OPERATING HEATER
Continued
CAUTION: Do not try to adjust heating levels by
using the equipment shutoff valve.
Ignitor Electrode
Light your gas appliance with the blower off. Turn the blower on
to deliver heated air at the top louvers. The blower features a
variable control which allows you to select the speed you desire.
If using the GA3650TA Blower Accessory:
In the ON position,
the blower will start when the thermostat senses a sufficient
increase in firebox temperature (approximately 10 to 20 min-
utes depending on heat setting).
Note:
Your gas stove and
thermostat blower will not turn on and off at the same time. The
stove may run for several minutes before the blower turns on.
After the heater modulates to the pilot position, the blower will
continue to run. The blower will shut off after the firebox
temperature decreases.
Note:
It is safe to operate stove with blower turned off. How-
ever, the blower helps distribute heated air from the stove.
Note:
Periodically check the louvers of the firebox and remove
any dust, dirt, or other obstructions.
OPERATING OPTIONAL
BLOWER ACCESSORY
Figure 21 - Control Knob and Ignitor Button Location
Control Knob
Ignitor Button
OPERATING HEATER
Lighting Instructions (Cont.)
To Turn Off Gas to Appliance
Thermostat Control Operation
Manual Lighting Procedure
Operating Optional Blower Accessory