DERMAVIT Diamond Shield Crystal Скачать руководство пользователя страница 5

 

 

Diamond Shield Crystal  

Instruction Manual 

 

Page 5 

 

Important Notices 

Safety Instruction 

  Use  only  the  supplied  grounding  cable.  Under 

no  circumstances  use  a  different  cable  for 
grounding. 

  Under  any  circumstances  never  insert  an 

electrode plug into an electrical outlet. 

  Always  insert  the  grounding  cable  to  the 

Diamond  Shield  Crystal  and  then  connect  it  to 
the power outlet. 

  Never  use  this  device  to  anyone  who  has  a 

pacemaker. 

  Never use this device in the eye area. 

  Keep the Diamond Shield Crystal always clean 

and  dry  –  wiping  it  with  a  damp  cloth  is 
permitted. 

Using  of  the  device  according  to  the  operating  instructions  is 
essential. DermaVit assumes no liability for misuse. 

 

 

Note 

In case of feeling a tingle  or burning on  your skin during the usage 
please  lower  the  intensity.  The  efficiency  is  independent  from  the 
above. When hypersensitive to metal, we gladly exchange the metal 
bracelets with cloth bracelets. 
 
The good effect of the earthing (so called negative ions) occurs only 
if the power socket is properly earthed. Be sure to check this with the 
power socket tester. 
 

Warning 
The  use  of  the  earthing  plug  (or  any  other  electrical 
appliances)  to  an  incorrect  power  socket  can  be 
perilous. 
Do not use the earthing cable during a thunderstorm. 

Содержание Diamond Shield Crystal

Страница 1: ...Diamond Shield Crystal Instruction Manual Page 1 Diamond Shield Crystal Wellness Device Micro Currents EMS Instruction Manual ...

Страница 2: ...Diamond Shield Crystal Instruction Manual Page 2 ...

Страница 3: ...re Identification 8 Front Side 8 Connection Side 9 Back side 10 Bringing into service 11 Insert the battery 11 Changing the battery 11 Connecting the cables 11 Operation 12 Menu Navigation 13 Main Menu 14 Standard menu 14 Display 15 Menu Settings 17 Working with the chip cards 19 Playing frequency programs from a chip card 19 Technical Data 20 Declaration of Conformity 21 For disposal 22 ...

Страница 4: ...MHz Possibility of very small voltages 0 1 V to high voltages 16 V Impulse discharge Wobble functionality Modulation of the output frequencies Constant current control Running frequencies from special chip cards optional accessory The operation can be done via a 9V battery or an appropriate rechargeable battery The device can be used to enhance the well being ...

Страница 5: ...ping it with a damp cloth is permitted Using of the device according to the operating instructions is essential DermaVit assumes no liability for misuse Note In case of feeling a tingle or burning on your skin during the usage please lower the intensity The efficiency is independent from the above When hypersensitive to metal we gladly exchange the metal bracelets with cloth bracelets The good eff...

Страница 6: ... cable for hand or bracelet electrodes Grounding cable and power socket tester 2 Bracelet electrodes Electrode belt 9V Battery Storage and transportation The equipment shall be always stored in dry closed rooms If the device is transported or stored in extreme temperatures a period of at least 2 hours should be observed for acclimatization before handling ...

Страница 7: ...g storage or transportation the ambient temperature can be between 20 C and 70 C If condensation has been formed during transportation or storage the device must acclimate for about 2 hours and dried by appropriate circulation Thereafter the operation of the device is permitted Nominal data with tolerances are valid after a warm up time of minimal 30 minutes at an ambient temperature of 23 C A val...

Страница 8: ...Shield Crystal Instruction Manual Page 8 Feature Identification Front Side 1 LED 2 LCD Display 3 Arrow keys 4 Mute Switch 5 Memory key 6 On Off switch 7 Start button 8 EXIT button 9 OK button 1 2 3 7 4 5 6 9 8 ...

Страница 9: ...Diamond Shield Crystal Instruction Manual Page 9 Connection Side 1 Grounding connection 2 Chip card slot 3 Connection for hand bracelet belt electrodes 1 2 3 ...

Страница 10: ...Diamond Shield Crystal Instruction Manual Page 10 Back side 1 Battery compartment 1 ...

Страница 11: ...the battery should be changed quickly Proceed as follows 1 Turn off the device 2 Remove the new battery from its package 3 Open the battery cover on the rear panel 4 On the basis of the old battery you will see the correct direction of insertion 5 Remove the old battery and replace it as quickly as possible with the new one The device is not damaged by an incorrectly inserted battery 6 If you are ...

Страница 12: ...D If the device is switched on the LED flashes When the battery is full the flashing frequency is slow When the battery charge is low the flashing frequency is faster If the battery is empty a message appears and the device can no longer be used The device is fully functional even if the battery is almost empty Activate deactivate the loudspeaker Press the sound button to switch the loudspeaker on...

Страница 13: ...ckly between the last and the first item in the menu A scroll bar on the display s right edge appears when the current list has more entries than can be displayed The scroll bar then indicates where you are in the list Confirm your selection with the OK button Then a new display that corresponds to the selected item appears depending on the selected element Press the EXIT key to return one level u...

Страница 14: ...andard menu Under Standard you find the pre installed frequency programs the Diamond Shield Zapper Crystal is supplied with by default The first level of the menu shows the available sequences When a sequence is selected and the OK button is pressed a list of the frequency programs of the selected sequence will be shown Executing a sequence Select the desired sequence with the and button Then pres...

Страница 15: ...ntact is made the unit will display for a short time the resistance in Kiloohm kΩ and then automatically start the execution of the frequency program During the execution of frequencies Display In the headline the sequence name and the name of the current single frequency program are shown in turns Below the remaining execution time is displayed minutes seconds Below the intensity is displayed For...

Страница 16: ...s to move up and down keys and Pressing the EXIT button will quit the current application Continuing an interrupted sequence If the execution of a sequence has been interrupted for some reason you can continue by pressing the Memory button This applies even if the sequence was interrupted because the battery has become empty during program execution Obviously the correct chip card must be inserted...

Страница 17: ...order to take over the adjusted time move to a different configuration entry by means of the arrow keys up or down Please also note the instructions in section Changing the battery AutoStart1 and AutoStart2 This shows whether the auto start of a program is active at a configured time By pressing the OK button you switch to the screen which provides the appropriate configuration See chapter Configu...

Страница 18: ...ignal The input is done with the arrow keys left and right Time Time of the auto start feature The left and right arrow keys change the hours or minutes The OK button switches back and forth between hours and minutes Run every The auto start function can be configured so that it is not carried out every day but e g every other day or every third day The input is done with the arrow keys left and r...

Страница 19: ... a chip card Regardless of the type of chip card their sequences and frequency programs can be played as follows 1 Insert the chip card in the device 2 Select the menu item chip card from the main menu and press the OK button 3 A submenu will pop up displaying the sequence s of the chip card 4 If you want to play an entire sequence then select this sequence and then press the START button 5 If you...

Страница 20: ...rodes Chip card slot Characteristic of the output signals Frequency range 0 5Hz 2 5MHz Waveforms square wave signal Minimum accuracy of the frequencies 100 ppm Output Voltage 0 1 16V measured from the 0V line Offset No offset positive offset positive offset 0 3V Modulation up to 254 times the output frequency 2 5 MHz must not be exceeded Wobble maximum up to twice the fundamental frequency Voltage...

Страница 21: ...ith applicable regulations EMV Richtlinien EMC Directives 2004 108 EG Elektromagnetische Verträglichkeit Electromagnetic compatibility DIN EN 61326 1 VDE 0843 20 1 2006 10 Elektrische Mess Steuer Regel und Laborgeräte EMV Anforderungen Teil 1 Allgemeine Anforderungen IEC 61326 1 2005 Deutsche Fassung EN 61326 1 2006 DIN EN 61326 2 6 VDE 0843 20 2 6 2006 10 Elektrische Mess Steuer Regel und Laborge...

Страница 22: ...liances or return it to the address below unfree postage will not be accepted Please also note that the disposal of batteries is prohibited on the normal household waste for environmental reasons You can return them free of charge to the public collection of communities or wherever batteries are sold You are welcome to return the batteries to the following address unfree postage will not be accept...

Страница 23: ...it GmbH Co KG All rights reserved Any kind of reproduction only with approval of DermaVit GmbH Co KG DermaVit GmbH Co KG Unterer Anger 15 Rgb 80331 Munich Germany Tel 49 0 89 18 90 84 6 0 Fax 49 0 89 18 90 84 6 15 E Mail info derma vit com Web http www derma vit com ...

Страница 24: ...Diamond Shield Crystal Instruction Manual Page 24 ...