background image

S

AFETY INSTRUCTIONS

 

 

 

10  

/

  24

 

DERMALOG FLC1 Light Edition User Guide 

3.6

 

Operation 

Make sure all people working with the DERMALOG FLC1 Light Edition have read and understood this user guide 
and received a thorough training. 

 

The DERMALOG FLC1 Light Edition contains a camera of the Intel® RealSense

TM

 D400 series. The Intel® 

RealSense

TM

 D400 series is classified as Class 1 Laser Product under the EN/IEC 60825-1, Edition 3 (2014) 

internationally and IEC60825-1, Edition 2 (2007) in the US. 

The Intel® RealSense

TM

 D400 series complies with US FDA performance standards under 21 CFR 1040.10 

for laser products except for deviations pursuant to Laser Notice No. 50 dated June 24, 2007. 

 

Caution – Use of controls or adjustments or performance of procedures other than those 
specified herein may result in hazardous radiation exposure. 

 

 

Do not power on the product if any external damage was observed. 
 
There are no service/maintenance, modification, or disassembly procedures for the stereo 
module and infrared projector. The system integrator must return modules before any failure 
analysis is performed. 

 

Do not attempt to open any portion of this laser product. 

 

Invisible laser radiation when opened. Avoid direct exposure to beam. 

 

There are no user serviceable parts with this laser product. 

 

Modification or service of the stereo module, specifically the infrared projector, may 
cause the emissions to exceed Class 1. 

 

No magnifying optical elements, such as eye loupes and magnifiers, are allowed. 

 

Do not try to update camera firmware that is not officially released for the specific 
camera module SKU and revision. 

 

 

 

If the DERMALOG FLC1 Light Edition makes strange noises, or gives off smoke, heat or strange odors, or other 
abnormalities occur when in use, immediately disconnect it from the computer. Then contact DERMALOG. 

Keep liquids away from the DERMALOG FLC1 Light Edition. 

Do not drop the DERMALOG FLC1 Light Edition or subject it to impact or strong shock. 

Use the DERMALOG FLC1 Light Edition only for the purpose it has been designed for.  

Do not connect other devices to the same USB hub. 

 
 

 

Содержание FLC1

Страница 1: ...User Guide DERMALOG FLC1 Light Edition Version 1 0 July 20 2020 ...

Страница 2: ...2 24 DERMALOG FLC1 Light Edition User Guide This page is intentionally left blank ...

Страница 3: ...ng to inform the parties about it Software documentation Copyrights 2004 2020 of DERMALOG Identification Systems GmbH All rights reserved This software documentation is property of DERMALOG Identification Systems GmbH and is made available in connection with a license agreement This documentation may be used or copied only in accordance with the conditions of the license agreement The documentatio...

Страница 4: ...REVISION HISTORY 4 24 DERMALOG FLC1 Light Edition User Guide Revision history Document Version Date Author Changes 1 0 2020 07 20 DERMALOG Initial document Table 1 Revision history ...

Страница 5: ...sal 11 4 Delivery package content 12 5 Technical data 13 6 Product description 14 6 1 Hardware 14 6 1 1 General views 14 6 1 2 Dimensions 15 6 2 Available software products 15 7 Installation 16 7 1 Position the DERMALOG FLC1 Light Edition 16 7 2 Connect the hardware 17 7 3 Install the software package 18 7 4 Calibrate the DERMALOG FLC1 Light Edition 18 8 Terms of Warranty 19 9 Ordering information...

Страница 6: ...ght Edition captures facial images and detects the body temperature of a person This user guide describes the DERMALOG FLC1 Light Edition It gives information on safety instructions technical data product description installation maintenance and disposal Figure 1 DERMALOG FLC1 Light Edition ...

Страница 7: ... text passages In step by step instructions and their prerequisites names of applications products chapters GUI elements tabs screen sections and areas keys menu paths italic Directories file names values document names messages email addresses and place holders in screen descriptions lowercase URLs and websites Table 4 Typographic conventions SYMBOLS AND ICONS Symbol Icon Meaning Introduces a sys...

Страница 8: ...mperature detection is no medical fever measurement In suspected cases a reference measurement with the clinical thermometer is necessary 3 2 General CUTTING DAMAGE Always check the DERMALOG FLC1 Light Edition for any visible damages before use Do not use the DERMALOG FLC1 Light Edition if you see any visible damage for example sharp edges broken safety coverings and so on as this may cause injury...

Страница 9: ...hapter 5 To achieve the best possible results it is recommended to operate the DERMALOG FLC1 Light Edition under the following conditions 20 C to 24 C 68 F to 76 F humidity 20 50 Provide adequate space around the DERMALOG FLC1 Light Edition for operation and maintenance Air circulation is required to cool the device Do not restrict the air flow around the device Use the DERMALOG FLC1 Light Edition...

Страница 10: ...isassembly procedures for the stereo module and infrared projector The system integrator must return modules before any failure analysis is performed Do not attempt to open any portion of this laser product Invisible laser radiation when opened Avoid direct exposure to beam There are no user serviceable parts with this laser product Modification or service of the stereo module specifically the inf...

Страница 11: ...any warranty If you need to return the DERMALOG FLC1 Light Edition for repair use a suitable packing material to avoid further damage preferrably the original packing material Check the DERMALOG FLC1 Light Edition regularly for damage and malfunction especially if the operating personnel change frequently In case of malfunction disconnect the USB cable and stop using the DERMALOG FLC1 Light Editio...

Страница 12: ...User Guide 4 Delivery package content The delivery package contains DERMALOG FLC1 Light Edition USB 3 0 cable USB C to USB A 1 m length Unless otherwise expressly agreed download the purchased software from the DERMALOG Support Center https support dermalog com ...

Страница 13: ...humidity 20 75 non condensing Please note To achieve the best possible results it is recommended to operate the DERMALOG FLC1 Light Edition under the following conditions 20 C to 24 C 68 F to 76 F humidity 20 50 Ambient temperature and humidity when storing or transporting the device 0 C to 40 C 32 F to 104 F humidity 10 90 non condensing Table 6 Technical data of DERMALOG FLC1 Light Edition The s...

Страница 14: ...6 1 Hardware 6 1 1 General views Figure 2 Figure 3 and Figure 4 show different views of the DERMALOG FLC1 Light Edition color camera infrared projector infrared camera thermal camera Figure 2 Front view of the DERMALOG FLC1 Light Edition UNC 1 4 20 thread for mounting the DERMALOG FLC1 Light Edition on a a suitable mount e g a tripod Figure 3 Side view and bottom view of the DERMALOG FLC1 Light Ed...

Страница 15: ...he dimensions of the DERMALOG FLC1 Light Edition Figure 5 Dimensions of the DERMALOG FLC1 Light Edition 6 2 Available software products The DERMALOG FLC1 Light Edition is operated with the DERMALOG Fever Detection Application For detailed information on the DERMALOG Fever Detection Application see the separate document DERMALOG Fever Detection Application User Guide ...

Страница 16: ...he best possible results it is recommended to operate the DERMALOG FLC1 Light Edition under the following conditions 20 C to 24 C 68 F to 76 F humidity 20 50 Provide adequate space around the DERMALOG FLC1 Light Edition for operation and maintenance Air circulation is required to cool the device Do not restrict the air flow around the device Use the DERMALOG FLC1 Light Edition only in a dry enviro...

Страница 17: ...person and the DERMALOG FLC1 Light Edition is between 0 5 m and 2 m Figure 6 Recommended alignment of DERMALOG FLC1 Light Edition 7 2 Connect the hardware Prerequisites You comply with the safety instructions see chapter 3 You have positioned the DERMALOG FLC1 Light Edition according to chapter 7 1 If you want to connect the DERMALOG FLC1 Light Edition via a USB hub always use a self powered activ...

Страница 18: ... Windows camera drivers are used STEP 4 In the Windows Start Menu type Device Manager open the Device Manager and check that the components of the DERMALOG FLC1 Light Edition are listed see Figure 7 Figure 7 Components of the DERMALOG FLC1 Light Edition FINISH You have connected the DERMALOG FLC1 Light Edition to the computer 7 3 Install the software package For information on the installation of ...

Страница 19: ...of the non observation of operating or maintenance instructions all claims and rights of the customer due to defects shall be barred This shall also apply if the defect is a consequence of incorrect use storage or foreign influence For the avoidance of doubt this exclusion of warranty shall not apply and DERMALOG shall be obliged to render warranty services for a defect when the customer proves th...

Страница 20: ...ORDERING INFORMATION 20 24 DERMALOG FLC1 Light Edition User Guide 9 Ordering information For ordering information please contact DERMALOG via sales dermalog com ...

Страница 21: ...CERTIFICATES DERMALOG FLC1 Light Edition User Guide 21 24 10 Certificates 10 1 DERMALOG Declaration of CE Conformity ...

Страница 22: ...CERTIFICATES 22 24 DERMALOG FLC1 Light Edition User Guide 10 2 Declaration of Conformity with the EU Directives 2011 65 EU and EU 2015 863 ...

Страница 23: ...This page is intentionally left blank ...

Страница 24: ...ffice DERMALOG Afis Asia Sdn Bhd 8 4 8th Floor Bangunan Malaysian RE No 17 Lorong Dungun Damansara Height 50490 Kuala Lumpur Malaysia Tel 60 3 20921316 Fax 60 3 20921690 asia dermalog com Philippine Branch Office DERMALOG Identification Systems GmbH 7 F Unit B 8 Rockwell Hidalgo Drive Rockwell Center Makati City 1210 Philippines Tel 63 2 683 7500 Fax 63 2 856 1138 office manila dermalog com Singap...