119
Interventions
FAULT 1
Replace the regulator as definitely faulty.
FAULT 2
a)
Check the output from the stator gives the correct voltage:
detach the stator connector, interpose an AC tester between
the grey-blue and black cables, and check the output voltage
is within the prescribed limits. If anomalies are found, repla-
ce the stator.
b)
If no anomalies are identified, replace the regulator.
c)
If the replacement of the regulator does not solve the fault,
check the electric connections.
Specific tooling
020331Y Digital multimeter
Characteristic
Voltage output at 3000 r.p.m.
25÷30V
FAULT 3
With the engine off and the regulator connector detached,
check there are no short-circuits in the system, with referen-
ce to ground. Then replace the regulator (with fuse) as this
is definitely faulty.
After replacing the regulator, measure the charge voltage
and current at the battery terminals.