29
5.5
Tank emptying and cleaning
To completely empty the tank
of liquid residue, proceed as follows:
- switch off the machine
- disconnect the vacuum cleaner from the power supply
- unscrew cap (E) on the side of the tank, allow the liquid residue to flow from the bottom of the
chamber
- Whenever you wish to clean the inside of the tank, remove the vacuum head (for details, see par.
5.3), then use a jet of water to clean the internal walls and the bottom of the tank.
To return to normal vacuum use
reverse the steps:
- position and block the vacuum head in the hatch (see par. 5.3)
- screw on the cap located on the side of the tank, connect the pump plug to the proper outlet on the
electrical panel
- connect the vacuum cleaner to the power supply
- turn on the vacuum cleaner, immediately assessing its efficient operation
Warning!
To prevent any damage to the liquid drain pump located in the tank, avoid directing the
waterjet on it
Warning!
Make sure the tap is screwed on and tightened properly, if not there could be leaks
during normal use
ONLY USE ORIGINAL DEPURECO FILTERS
E