A specially trained operator must always be present during the
operation of the equipment and must intervene immediately
stopping the equipment using the emergency button in case of
malfunctions, for example due to abnormal noise (breakage of
components), clogging of the loading and venting, rupture of the
filter bags, aspiration of bodies, presence of foreign bodies or
sources of ignition.
For the installation and maintenance of electrical parts (eg.
Cables, cable glands and terminals) always follow the indications
of EN 60079-14.
In case of opening the junction boxes (for inspections) check
the correct presence of the gaskets when they are closed again.
The plug is not of the ATEX type (or is not supplied): the user
must connect the plug to a socket located in a SAFE PLACE, or
must install an ATEX plug.
The flexible pipes, the suction openings and the filtering bags
are of the antistatic type declared by the respective
manufacturers.
It is forbidden to use components of different types.
The protection against atmospheric discharges must be present
in the plant where the equipment is used.