8-5 Checking/every 1000 hours
Checking/every 250 and 500 hours is also required.
(1) Cleaning inside fuel tank
Drain the fuel in the fuel tank completely,
and wash out deposits and water collected
inside the tank.
(2) Replacement of air cleaner element
The element should be replaced referring to "Cleaning of air cleaner element".
Parts number of air cleaner element :
Model name
Parts number
manufacture
Parts number of manufacture
DCA-60ESI2
Y06020 46365
DONALDSON
P82-8889
(3)
Checking on rubber suspension
Check on the rubber suspension, whether it is damaged or deformed by the oil.
Contact distributor or our office to replace the rubber suspension, if necessary.
(4)
Checking on nylon and rubber hose
Check on the nylon and rubber hose, whether they are hardened or deteriorate.
Contact distributor or our office to replace the nylon hose and rubber hose, if
necessary.
(5)
Checking on lining
Check on the lining, whether it deteriorates greatly, or it is stained by clinging of oil
or the like, or it is removed. Contact distributor or our office to replace the lining, if
necessary.
-
63
-