![Denyo DCA-30ESX Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/denyo/dca-30esx/dca-30esx_instruction-manual_2485065067.webp)
Phenomenon
Assumed cause
Action
Discharged battery
Charge or
replace
Cell m otor
will n o t run
Detached or loosened o r corroded
battery terminal
Repair
E ngine will
or revolution
F u se blow
Replace
speed is low
Im proper starter switch
Replace
n o t start up
Im proper sta rter
Replace
Broken lead wire
Repair
Fuel shortage
Supply
Cell m otor runs
Blinded fuel filter
Replace elem ent
Air in fuel system
Remove
Speed will not rise
Air in fuel system
Remove
Blinded fuel filter
Replace elem ent
Compression failure
Repair engine
Blinded air cleaner
Replace elem ent
E ngine stop by oil failure
Oil shortage
Supply
Oil pressure switch failure
Replace
Blinded oil filter
Replace elem ent
Cooling w ater shortage
Supply
O ver heat
Fan belt looseness
Adjust
(w ater tem perature)
Blinded core of radiator
Clean
Engine therm ostat failure
Repair
V oltm eter failure
Replace
AVR failure
Burned ZNR
Contact
Voltmeter will not operate
Burned rotary rectifier
distributor or
Disconnected rotor wiring
our office
Burned generator wiring
Voltm eter failure
Replace
AVR failure
VR failure
Contact
R ated voltage will n o t be
Burned rotary rectifier
distributor or
reacnen
Burned ZNR
our office
Burned generator wiring
Low speed
Increase