![Denyo DCA-30ESX Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/denyo/dca-30esx/dca-30esx_instruction-manual_2485065024.webp)
(5) Fuel priming pump button
The 30ESX,40ESX is provided with an fuel priming
Pump button. The button is used to vent the air
contained in fuel piping before the engine that has been
stopped because of fuel shortage, etc. is started.
In such a case, set the starter switch to "Run", press
down the fuel priming pump button for about 1 minute,
and then start the engine.
If the engine rotation is found unstable after it is started,
press down the button again for about 10 seconds while
the engine is running.
With the 30ESX air vent can also be performed with the priming pump located at
the top of the filter. If air cannot be vented completely when this button, press the
priming pump several times.
I f the engine still rotates unstably or still fails for starting, clean up the Fuel Filter
Element located into the Fuel Pump, or replace it to new one.
P arts number of fuel filter elem ent located into the fuel pump:
Model name
Parts num ber
manufacture
Parts number of manufacture
DCA-30ESX
Y06020 42425
ISUZU
894437-0220
DCA-40ESX
Voltage regulator and overcurrent relay
(1) Voltage regulator
Tliis regulator is used to control the output voltage.
Turn the regulator to clockwise to increase the voltage
and counter clockwise to decrease it.
Adjust the voltage to the rated voltage with this
regulator.
(2) Overcurrent relay
This relay is used to trip the circuit breaker when overcurrent
flows into the circuit.
[Note]
Do not change the set value unnecessarily.
- 23 -