MAINTENANCE
1.
Daily Care
A. Clean casting well.
B. Remove all alloy splash with emphasis particularly on Melt Coil.
C. Check optical radiation pyrometer adjustments.
2.
Weekly Care
A. Clean guide rods along with the crucible holder slides.
B. Establish a free movement of crucible carriage.
3.
Monthly Care
A. Remove front panel and vacuum accumulated dust and dirt inside of the unit.
B. Check H.F. flexible leads for parallelism and proper separation.
C. Inspect for water leaks and cleanliness of water filter cartridge.
D. Check for water leaks.
4.
Every 60 to 90 days
A. Adjust H.F. flexible leads for parallelism and proper separation.
B. Check calibration of grid current.
REPLACEMENT PARTS
CATALOG #
DESCRIPTION
N031106
Crucible.
N154501
Quartz Rod.
N154535
Sighting Crucible.
N154553
Crucible Tongs.
N154801
Carbon Dummy Mold.
N154861
No. 1, 1 1/4 Ring Holder.
N154862
No. 2, 1 1/2 Ring Holder.
N154863
No. 3, 1 3/4 Ring Holder.
N154864
No. 4, 2 1/4 Ring Holder.
N154865
No. 5, 2 3/4 Ring Holder.
N154866
No. 6, 3” Ring Holder.
N154867
No. 7, 3 1/4 Ring Holder.
N154868
No. 8, 3 1/2 Ring Holder.
N242903
Carbon Crucible Insert.
Electromatic - 4
19
CAUTION:
Be sure Main POWER SWITCH is OFF