DentalEZ RAM VAC COSP22S Скачать руководство пользователя страница 1

O

SPREY

Osprey

TM

 

Dental Compressor

User Manual

Содержание RAM VAC COSP22S

Страница 1: ...OSPREY Osprey TM Dental Compressor User Manual ...

Страница 2: ...Requirements 9 Section III Installation Feet Kit 11 Filter Drain Kit 12 Low Voltage Wiring Kit 14 Low Voltage Remote Switching 15 Outlet Plumbing Kit 17 Section IV Operation Theory of Operation 19 Getting Started 19 C2 Control Display Screen 20 Enable High Pressure Mode 23 Section V Care Cleaning 25 Maintenance 25 Section VI User Service Information Service Instruction 31 Disposal of Equipment 31 ...

Страница 3: ...www DentalEZ com 866 DTE INFO ii OspreyTM Compressor PN 1045DOC_E ...

Страница 4: ...h the components of the basic and smart compressor models Figure 1 After the compressor is installed review the features operation procedures and care guidelines with the doctor s staff Leave this manual in the doctor s office Product Overview Installation by an authorized RAMVAC dealer service technician is recommended For any questions about an order please contact a RAMVAC customer service repr...

Страница 5: ...ompressor Dual column desiccant dryer provides 100 continuous supply of the driest cleanest air in the dental industry While one column is drying the other is in operation Stores air at 40 C preventing growth of harmful bacteria Design allows for easy desiccant cartridge replacement Industry leading 6 year 4 200 hour whichever comes first warranty Models available suited for 2 up to 11 users Outpe...

Страница 6: ... 30 41 29 32 Weight 160 lbs 190 lbs 190 lbs 250 lbs 260 lbs 385 lbs Tank Size 12 gallon 12 gallon 12 gallon 20 gallon 20 gallon 30 gallon dB Levels N A N A N A N A N A N A CFM 80 PSI 6 0 6 6 6 6 9 3 12 0 18 1 Operating Pressures 586 kPa 85 PSI to 793 kPa 115 PSI with 2 Total Error Band 586 kPa 85 PSI to 793 kPa 115 PSI with 2 Total Error Band 586 kPa 85 PSI to 793 kPa 115 PSI with 2 Total Error Ba...

Страница 7: ...s with NFPA 99C level 3 piped gas and vacuum requirements Manufactured in a FDA registered ISO 13485 2016 certified facility The authorized European representative is Dental Hygienics Decontamination DHD 41 Blackwell Drive Braintree Business Park Braintree Essex CM7 2PU UK Phone 44 01787 877877 ext 200 Caution Warning Biohazard Warning Dangerous Voltage Hot Surface General Mandatory Action Refer t...

Страница 8: ...ompressor and remove power from compressor when servicing Turn off power at disconnect or service breaker Danger of fire or explosion when using flammable substances Never leave children unattended when compressor is in use The compressor has several guards designed to protect against accidental contact with dangerous components Do not remove these guards until power has been disconnected turned o...

Страница 9: ...lt in increased emissions or decreased immunity of the compressor Portable and mobile radio frequency RF communications equipment can affect medical electrical equipment There may be an instance in low humidity environments that the user of the dental compressed air system may cause the compressor to stop as a result of electrostatic discharge ESD energy To remedy this issue push the START button ...

Страница 10: ...essor for lifting Figure 2 NOTE LIfting the compressor assembly by any other part or location could result in damage to the compressor Section II Preinstallation Packaging To prevent tipping during transport securely fasten unit to shipping pallet until final destination has been reached WARNING 5 Verify additional Osprey parts shipped with the compressor for use at installation Outlet Plumbing Ki...

Страница 11: ...g of the device which could result in damage to the compressor CAUTION the compressor supplied to ensure unit stands firmly on the floor see Section III Installation Floors should be wood concrete or ceramic tile It is highly recommended that a higher than 30 relative humidity be established and the operator wear a ground strap before physical contact is attempted Compressor is for indoor use only...

Страница 12: ...mbing Attach drain tubing to fitting on bottom of coalescing filter and direct it into floor drain for proper disposal of water Connect compressor air outlet to facility plumbing with provided supply hose 3 8 3 8 MPT 6 feet in length Install particulate filter to the facility shut off valve using plumbing kit connectors provided Install fresh air manifold and connect fresh air intake kit supplied ...

Страница 13: ...www DentalEZ com 866 DTE INFO 10 OspreyTM Compressor PN 1045DOC_E ...

Страница 14: ...mply with all safety requirements of federal state or local agencies or safety requirements of the installer s employer If a conflict does exist follow the requirements set forth by the other organizations Parts Included Foot 4 Pieces Flanged Nut 4 Pieces Tools Required 7 16 Wrench 1 2 Wrench Assembly 1 Remove the four nuts 7 16 wrench from the bolts that secure the Osprey compressor legs to the w...

Страница 15: ... Feet Kit Continued WARNING Prior to starting this assembly read understand and follow the safety information and the assembly instructions in this user manual The bowl on the coalescing filter assembly is under high pressure while the system is running Allow the compressor to stop running and release the air from the un loader valve prior to removing the bowl Failure to allow the system to proper...

Страница 16: ...drain are a push to connect style of fitting and do not require any tools to install After determining proper routing simply insert either the hose end or the elbow fitting into the fitting on the bottom of the coalescing filter bowl Apply light force until the item stops Gently pull the opposite direction on the hose or fitting to determine if they have properly seated into the connection If the ...

Страница 17: ...ic cover with the RAMVAC logo on it it is a basic control version if the compressor has a C2 control it is considered a smart control The instructions in this manual contain information for wiring both versions so care is required to make sure the proper instructions are used Figure 9 2 This kit contains wire nuts required to make the connections to the basic control and the FGH connector required...

Страница 18: ...ff at end of day Illuminated Remote Panels Switch light is steady on when system is running normally Switch light flashes for maintenance or one of the heads has been disabled by the disable button on the C2 control Non illuminated Remote Switches Non illuminated switches provide no indication for system status RAMVAC OWL TouchTM Touchpad illuminates while equipment is running OWL on wall logic gi...

Страница 19: ... Connection OWL Connection Low Voltage Switch Wires Red Black Purple OWL Touch OWL Hub C2 Control RAMVAC Remote Panel or Equivalent with Illuminated 24V DC Switch 1 2 3 F G H C2 Control Terminals Purple Red Black Basic Control Wires F H G 1 2 3 Air Switch Air Light Common 24V DC Purple 24V DC Red DC Common Black Toggle Switch or Other Non Illuminated Switch Option F H C2 Control Terminals Purple B...

Страница 20: ...essor is designed for dental procedures and powering dental equipment and can be safely used in the oral cavity for such purposes Under no circumstances should it be supplied or considered as medical breathing air for a patient WARNING Installation of this device should be conducted by licensed electrical and plumbing contractors and should always follow the instructions found in the various manua...

Страница 21: ...ad sealer just a couple of drops on the male threads of all the fittings will provide an adequate seal Tighten fittings as needed 3 Thread the final filter onto the fittings and tighten it into the desired position Note the final filter has to be installed in the correct flow orientation 4 Thread the facility supply hose into the final filter and tighten Both ends of the hose have swivel fittings ...

Страница 22: ...air pressure When air is called for to run equipment in the facility it goes through a particulate filter to remove any remaining particulates from the air The tank pressure is monitored by a pressure switch on the basic models with the operating pressure from 85 to 115 PSI Pressure adjustment is not recommended and will void the warranty The smart models are monitored by a pressure transducer in ...

Страница 23: ... dryer shuttle valve will relocate itself to the correct position after 35 seconds and after which the dryer will cycle normally Getting Started Continued C2 Control Display Screen Electronic Display Control Buttons 4 Remote Switch Connection OWL Communication Cable Cat 6 Motor Disable Figure 12 Osprey compressor C2 smart control panel The C2 smart control platform utilizes state of the art techno...

Страница 24: ...erage time last 60 cycles to drain the system from 115 to 85 PSI Instantaneous amp reading Hours of runtime for each head not system hours Can be reset when motor is replaced Instantaneous amp reading Hours of runtime for each head not system hours Can be reset when motor is replaced Instantaneous amp reading Hours of runtime for each head not system hours Can be reset when motor is replaced SCREE...

Страница 25: ...êìñð âîëé îáéëðá Ñóè Touch system ÖÝêç ìîáïïñîá åê ìëñêàï ìáî ïíñÝîá åêßä ÒÕË ÖÝêç ìîáïïñîá îáÝàåêã äåãäáî ðäÝê áôìáßðáà Troubleshoot for malfunction Ïëðëî Ýéìï ÝÞëòá äåãä èáòáè ïáð ìëåêð Ðë Ýéìï ëî èëóáî Ýéìï ðäÝê áôìáßðáà Lost connectivity with Owl Hub Check cable and connections System hours counted only when unit is activel running Òáîâëîé Ĝèðáî éÝåêðáêÝêßá Ýêà îáïáð ðåéáî Þõ äëèàåêã RESET but...

Страница 26: ...onds The screen will now display HI PRESSURE MODE ON 105 130 PSI Figure 15 3 Press NEXT button Screen will display this warning IN HI PRESS MODE OWL COM DISABLED This indicates that the On Wall Logic OWL Smart Hub is in high pressure mode and will have limited functionality with the compressor Figure 16 Figure 14 Press NEXT button to cycle to screen Figure 15 Press and hold RESET button for 10 sec...

Страница 27: ...www DentalEZ com 866 DTE INFO 24 OspreyTM Compressor PN 1045DOC_E ...

Страница 28: ...e coalescing and particulate filters indicator every month see Checking Moisture Indicator and Checking Filter Element Service Indicator in this section Keep compressor clean and free of dirt Keep area surrounding compressor free of debris Maintain a controlled ambient temperature between recommended levels High temperatures will shorten the life of the air compressor see Section I Introduction Sp...

Страница 29: ...e screen on the C2 control and pressing the RESET button Osprey basic models There is no maintenance alarm Maintenance Continued Replacing Intake Filter Tools Required Phillips head Screwdriver NOTE All models us the same intake filter 1 Turn compressor OFF a For smart models use the STOP button on the C2 control b For basic models use the switch toggle turning it to the off position 2 Remove powe...

Страница 30: ...ace 7 Return power to compressor 8 Return compressor to service Replacing Particulate Filter NOTE All models us the same intake filter 1 Turn compressor OFF a For smart models use the STOP button on the C2 control b For basic models use the switch toggle turning it to the off position 2 Remove power from the compressor 3 Bleed air from the system 4 Push up slightly and turn particulate filter bowl...

Страница 31: ...66 DTE INFO 6 Return compressor to service Maintenance Continued Testing Safety Valve 1 Run compressor until 45 PSI shows on the gauge 2 Pull ring on safety valve Figure 21 NOTE Safety valve located below the facility shut off valve A loud burst of escaping air will be heard when air is released from the safety valve 3 If no air comes out of safety valve the valve is defective and must be replaced...

Страница 32: ...ement should be replaced NOTE Replace an element annually even if the red indicator does not reach the top Section V Care Maintenance Continued Testing Compressor for Leaks 1 Close valve to facility plumbing 2 Run compressor until it shuts off at 100 PSI 3 Turn compressor OFF a For smart models use the STOP button on the C2 control b For basic models use the switch toggle turning it to the off pos...

Страница 33: ...www DentalEZ com 866 DTE INFO 30 OspreyTM Compressor PN 1045DOC_E ...

Страница 34: ...etal Salvage Remove all aluminum and steel components for recycle as metal salvage Plastic Salvage Remove all plastic components for recycle as plastic salvage Biologically Contaminated Salvage Cuspidor waste lines from the cuspidor and the oral extraction lines should be handled with precaution and disposed of appropriately Non Salvage Components All other material unsuitable for recycling should...

Страница 35: ...www DentalEZ com 866 DTE INFO 32 OspreyTM Compressor PN 1045DOC_E ...

Страница 36: ...33 www DentalEZ com 866 DTE INFO 33 PN 1045DOC_E Section VII Parts Lists Diagrams To order parts online visit www dentalezparts com or scan QR code with smartphone DentalEZ Parts Online ...

Страница 37: ...www DentalEZ com 866 DTE INFO 34 OspreyTM Compressor PN 1045DOC_E ...

Страница 38: ...Environment Guidance Electrostatic Discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 2 kV contact 2 kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Electrical Fast Transient Burst IEC 61000 4 4 2 kV for power supply lines 1 kV for input output lines 2 kV for power supply lines not applicable No data I 0...

Страница 39: ...y with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the Osprey family of dental air compressors is used exceeds the applicable RF compliance level above the equipment should be observed to verify normal operation If abnormal performance is observed addition...

Страница 40: ...ot covered under this warranty nor is normal wear and tear Failure to follow or observe our operating use maintenance and or installation instructions voids this warranty as does the use of non authorized parts and repairs made by an unauthorized repair facility Liabilityislimitedtorepairorreplacementofthedefectivepart s orproductsatoursolediscretion Allotherliabilities inparticular liability for ...

Страница 41: ... DentalEZ Alabama Inc Printed in USA PN 1045DOC_E April 2019 2500 Highway 31 South Bay Minette Alabama 36507 866 DTE INFO www dentalez com ...