![Denso Keyence Vision XG Series Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/denso/keyence-vision-xg-series/keyence-vision-xg-series_manual_2483252029.webp)
29
画像処理システム/XGシリーズ
<ImplVar>
.TriggerAndGetResult
Usage
Issues a specified trigger and acquires the processing result of images.
Syntax
<ImplVar>
.TriggerAndGetResult (
<Trigger No.>
)
Argument: <Trigger No.> Specify the number of trigger to issue (integer).
1 – 4: Trigger 1 to 4
-1: All triggers
Return value: Output data specified for the result output unit is stored. If acquisition
fails, -1.0 is stored. (Variant type)
Description
Issues a specified trigger and acquires the processing result specified for the output
unit of the XG series-side.
Example
Dim caoCtrl as Object
Dim vntResult as Variant
caoCtrl=cao.AddController("XG","CaoProv.KEYENCE.VWXG", "", "conn=eth:192.168.0.10")
vntResult = caoCtrl.TriggerAndGetResult( -1 )