![Denso Keyence Vision XG Series Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/denso/keyence-vision-xg-series/keyence-vision-xg-series_manual_2483252027.webp)
27
画像処理システム/XGシリーズ
<ImplVar>
.ExecuteCommand
Usage
Executes a specified non-procedural command.
A command response is acquired regardless of whether the command execution is
successful or not.
Syntax
<ImplVar>
.ExecuteCommand (
<Non-procedural command>
)
Argument:
<Non-procedural command> Specify a command with a character
string.
Return value:
Command response is returned with a character string. If acquisition
fails, the character string is not stored. (Variant type)
Description
For the supported non-procedural commands, refer to the reference manual of
V-Works for XG ActiveX control for XG series.
Example
Non-procedural command R0: The following shows an example of entering run mode.
Dim caoCtrl as Object
Dim vntResult as Variant
caoCtrl=cao.AddController("XG","CaoProv.KEYENCE.VWXG", "", "conn=eth:192.168.0.10")
vntResult = caoCtrl.ExecuteCommand("R0")
'Enter run mode
Содержание Keyence Vision XG Series
Страница 1: ...11 文書のタイトルを入力 1 KEYENCE Image Processing System MODEL XG Series ...
Страница 36: ......