Chapter 12. Power-related Functions
159
12.3 Wakeup Function
The wakeup function allows you to turn the BHT on at the wakeup time (of the system clock)
specified in user programs.
To set the wakeup time, use the
TIME$
function as follows:
(1)
Set 1 to bit 2 on port 8.
Switches the
TIME$
function to the setting of the
wakeup time.
(2)
Set the wakeup time by using the
TIME$
function.
(3)
Set 1 to bit 0 on port 8.
Activates the wakeup function.
To confirm the preset wakeup time, use the
TIME$
function as follows:
(1)
Set 1 to bit 2 on port 8.
Switches the
TIME$
function to the setting of the
wakeup time.
(2)
Retrieve the wakeup time by using the
TIME$
function.
TIP
If you set or retrieve the system time or wakeup time by using the TIME$ function,
then the value of bit 2 on port 8 will be automatically reset to zero.
When bit 2 on port 8 is zero, you can set or retrieve the current system time by using
the TIME$ function.
By reading the value of bit 1 on port 8 in user programs, you may confirm the initia-
tion option of the BHT. If this bit is 1, it means that the BHT is initiated by the
wakeup function and if 0, it means that it is initiated by the PW key.
Содержание BHT-BASIC 100 SERIES
Страница 1: ......
Страница 161: ...153 Chapter 10 Sleep Function CONTENTS 10 1 Sleep Function 154...
Страница 163: ...155 Chapter 11 Resume Function CONTENTS 11 1 Resume Function 156...
Страница 173: ...165 Chapter 13 Backlight Function CONTENTS 13 1 Backlight Function 166...
Страница 192: ...Chapter 14 Statement Reference 184 Example OPEN master Dat AS 1 FIELD 1 20 AS bar 10 AS ky CLFILE 1 CLOSE 1...
Страница 249: ...241 Example CLOSE IF kyIn Y THEN KILL Master Dat END IF Reference Statements CLFILE...
Страница 349: ...341 Run time errors Error code Meaning 05h Parameter out of the range checktype is out of the range...
Страница 383: ...375 Run time errors Reference Error code Meaning 05h Parameter out of the range Functions LEFT LEN and RIGHT...