
180
BHT-904B/BHT-914B
Error No.
Cause Details
Remedy
The BHT communication interface
specification is illegal.
Specify IrDA (Optical) if connected to the PC via
the CU, and Connector if connected via the
interface connector. Refer to QBdirect (page 175,
Note 1) for details of the setting method
The Transfer Utility “Communication port”
option specification is illegal.
Specify the communication port to which the BHT is
connected for the “Communication port” option.
The transmission speed at the BHT and PC
does not match.
Ensure that the transmission speed at the BHT and
PC matches.
Please be aware that the default transmission
speed differs depending on the BHT used.
The communication condition of the
uncorrespondence is set to CU.
CU-921 corresponds only to the transmission rate
115200bps and 460800bps.
Please set it to these transmission rates.
The protocol specified at the BHT and PC
does not match.
Ensure that the protocol matches.
Please be aware that the default protocol differs
depending on the BHT used.
The PC communication port setting is illegal.
Enable “Use FIFO buffer. (16550 interchangeable
UART required.) (U)” setting for the communication
port used.
51
52
Hardware malfunction.
Please contact your dealer.
53
The protocol specified at the BHT and PC
does not match.
Ensure that the protocol matches.
Please be aware that the default protocol differs
depending on the BHT used.
The protocol specified at the BHT and PC
does not match.
Ensure that the protocol matches.
Please be aware that the default protocol differs
depending on the BHT used.
55
An attempt was made to download a file with
field width differing from that of the data file
already existing in the BHT.
It is not possible to download a file with the same
name but different field width from the file already
existing in the BHT.
Either delete the existing data file in the BHT, or
specify the same field format as the existing data
file.
55
71
Illegal characters have been used in the file
name.
Change the file name.
Refer to QBdirect (page 175, Note 1) for details of
characters that can be used in file names.
The COM port number used has already
been used.
Please use another COM port number, or use it
after shutting the COM port under use.
The COM port number used doesn't exist.
Please use the existing COM port number.
75
The communication condition of the
uncorrespondence is set to CU.
CU-921 corresponds only to the transmission rate
115200bps and 460800bps.
Please set it to these transmission rates.
91
Illegal field information specification option
when transmitting data file.
Set a correct value for the field information option.
Содержание BHT-904B
Страница 1: ...Barcode Handy Terminal BHT 904B BHT 914B User s Manual...
Страница 14: ...xiii BHT 904B BHT 914B...
Страница 46: ...32 BHT 904B BHT 914B...
Страница 160: ...146 BHT 904B BHT 914B...
Страница 170: ...156 BHT 904B BHT 914B...
Страница 197: ...183 Barcode Handy Terminal...