background image

14 

DM-5103 

DENRYO CO., LTD. 

28-5, Nishinippori 2Chome, Arakawa-ku,
Tokyo 116-0013, Japan
Phone: +81-3-3802-3671
Fax: +81-3-3802-2974
Email: 

[email protected]

www.denryo.com/en

Содержание PANcharge1k

Страница 1: ...PANcharge1k Battery Charger User s Manual Ver 1 00E ...

Страница 2: ...Drawings 5 2 2 Front Panel 5 2 3 Rear Panel 5 2 4 Specification 6 3 Installation and Settings 7 3 1 Installation location 7 3 2 Battery Type 7 3 3 Connection 8 3 4 Operation Setting 9 4 Operation 10 4 1 Battery Charging Curve 10 4 2 Operation and LED Indicators 11 4 3 LED Indicator of Error 12 4 4 Protection 12 5 Troubleshooting 13 2010 2018 DENRYO CO LTD All Rights Reserved ...

Страница 3: ...tric shock to protect from external radio interference and not to radiate harmful emissions The earth cord is connecting with the charger s chassis To avoid the risk of electric shock and fire adjust the AC power switch in the rear of the charger to the same voltage as the input one Plug the proper power cord to the plug in NEVER input 230Vac with the 115Vac setting It may lead to a fire electric ...

Страница 4: ...radio communication Operation of this equipment in a residential area is likely to cause harmful interference When the interference happens because of the ON OFF of the charger follow one of the steps below to solve the problem Reset the direction of receiver antenna or adjust the mounting location Set the charger apart farther from the receiver Do not connect the receiver and charger into in the ...

Страница 5: ...100 120Vac For AC input 200 240Vac prepare a cable applies to 200 240Vac AC fuse holder 20A 250Vac φ6 35mm length 31 75mm fuse built in NOTE Please replace the fuse with the same specification if replacement is required AC Input voltage switch AC 115 230Vac adjustable Set 115 for input 115Vac set 230 for input 230Vac NOTE Set the switch with voltage as same as the AC input DO NOT input 200Vac unde...

Страница 6: ... 120Vac 180 240Vac Input frequency 50 60Hz No load current Less than 0 1A Max Efficiency Full load 80 Average Full load Current Less than 20A Average Battery voltage 12V 24V 36V 48V Charging voltage range 8V 14 8V 16V 29 6V 30V 42V 40V 60V Charging voltage 14 5V 29V 43 5V 58V Float voltage 13 8V 27 6V 41 4V 55 2V Max charging current 30A 30A 25A 15A Absorption min current 2 25A 2 25A 2 25A 2 25A B...

Страница 7: ...charge1k in a horizontal position as far as possible Picture 3 1 Mounting drawing 3 2 Battery Type PANcharge1k can charge lead acid batteries includes sealed lead acid battery and non sealed lead acid battery Charging non lead acid batteries or lead acid batteries with higher capacity than the list below may cause charger broken In this case the warranty is not applied WARNING Only charge batterie...

Страница 8: ...use risk of electric shock Battery charging cord Do not connect battery and charging cord before setting charging voltage and charge begins Moreover to prevent short circuit of charging clips cover the clips when it is disconnected anything AC power cord Make sure AC power switch is off Make sure grounding wire on the plug of AC power cable grounds properly Plug AC power cord into connector in the...

Страница 9: ...er switch to turn charger on Step 5 All LED indicators light for 2 seconds Afterward red LED flashes indicate the charging clips is disconnecting to battery The rectangle LED indicates the set charging voltage Step 6 Set charging voltage by pressing the switch key around 0 5 seconds The setting order is 12V 24V 36V 48V 12V The number of rectangle LED lights reflects to the charging voltage user ch...

Страница 10: ...k outputs and charges by a constant current In absorption charging stage battery voltage is constant but the current is decreasing and battery generates gas In the last stage of floating charging charger charges with constant low voltage maintains the battery at 100 state of charge If the battery does not connect to any load it is normally charged with a very low current Picture 4 1 Charge Charact...

Страница 11: ...rectangle LED all light up initially and turn to display the percentage of battery capacity charged by the amount it lights Step 9 Yellow round LED flash slowly The LED turns to flash yellow slowly means it is charging in a constant current the bulk charging stage At the time the numbers rectangle LED light up increases with the capacity has been charged Step 10 Yellow round LED flash quickly The ...

Страница 12: ...ributor 4 4 Protection Short circuit protection It will not be damaged even the output terminal is short circuited Reverse connection protection It will not be damaged even battery is reversely connected Over temperature protection Fan spins when charger internal temperature rises above a certain level and switches to strong or weak automatically depending on the temperature Fan stops when the tem...

Страница 13: ...flashes red for two times Bad connection between charging clips and battery terminals Check if charging clips are connecting firmly Charger defect Contact us or the distributor Temperature protection error displays and charging stops Round LED flashes red for five times Internal temperature is too high that the over temperature protection works Locate the charger in a ventilation well location and...

Страница 14: ...14 DM 5103 DENRYO CO LTD 28 5 Nishinippori 2Chome Arakawa ku Tokyo 116 0013 Japan Phone 81 3 3802 3671 Fax 81 3 3802 2974 Email info en denryo com www denryo com en ...