12
4-3. LED Indicator of Error
Times
flashed
(times)
Possible cause
Solution
2
Charging clips are not connecting to
the battery.
Fuse of output terminal is broken.
Connect charging clips to the battery.
Contact us or the distributor if
charging clips connected and charger
still errors.
3
The voltage of the Battery connected is
too high or too low that exceeding the
range of charging voltage.
Check if the battery voltage is available for
the charger. (Refer to P.6)
4
The temperature sensor in the charger
is short-circuited or opened.
The temperature sensor is error. Contact
us or the distributor.
5
The internal temperature is too high that
the over temperature protection is
working.
Wait for the charger to cool down. It
restarts automatically after temperature
down.
6
Other problem is happened.
Contact us or the distributor.
4-4. Protection
Short-circuit protection
: It will not be damaged even the output terminal is short-circuited.
Reverse connection protection
: It will not be damaged even battery is reversely
connected.
Over temperature protection
: Fan spins when charger internal temperature rises above a
certain level, and switches to strong or weak automatically depending on the temperature. Fan
stops when the temperature drops beyond a certain level. However, once the temperature rises
higher than the general level, LED turns to error display. Leave it for a while and wait for the
temperature drops to the normal level; charger recovers and charging restarts.
Input protection
: An abnormal current flow in internal charger because of the charge itself or
other external factors, the protection works by melting the fuse of the input power.
Output protection:
Due to the trouble of charger itself or other external factors, abnormal
current flows between the charger and battery. The fuse gets melt to protect the charger and
safety.