background image

3

SAFETY INSTRUCTIONS

1.

Read Instructions – All the safety and operating
instructions should be read before the appliance is
operated.

2.

Retain Instructions – The safety and operating instructions
should be retained for future reference.

3.

Heed Warnings – All warnings on the appliance and in the
operating instructions should be adhered to.

4.

Follow Instructions – All operating and use instructions
should be followed.

5.

Water and Moisture – The appliance should not be used
near water – for example, near a bathtub, washbowl,
kitchen sink, laundry tub, in a wet basement, or near a
swimming pool, and the like.

6.

Carts and Stands – The appliance should be used only with
a cart or stand that is recommended by the manufacturer.

6A.

An appliance and cart
combination should be
moved with care.
Quick stops, excessive
force, and uneven
surfaces may cause
the appliance and cart
combination to overturn.

7.

Wall or Ceiling Mounting – The appliance should be
mounted to a wall or ceiling only as recommended by the
manufacturer.

8.

Ventilation – The appliance should be situated so that its
location or position does not interfere with its proper
ventilation. For example, the appliance should not be
situated on a bed, sofa, rug, or similar surface that may
block the ventilation openings; or, placed in a built-in
installation, such as a bookcase or cabinet that may
impede the flow of air through the ventilation openings.

9.

Heat – The appliance should be situated away from heat
sources such as radiators, heat registers, stoves, or other
appliances (including amplifiers) that produce heat.

10.

Power Sources – The appliance should be connected to a
power supply only of the type described in the operating
instructions or as marked on the appliance.

11.

Grounding or Polarization – Precautions should be taken so
that the grounding or polarization means of an appliance is
not defeated.

FIGURE  A

EXAMPLE  OF  ANTENNA  GROUNDING

AS  PER  NATIONAL

ELECTRICAL  CODE

ANTENNA
LEAD  IN
WIRE

GROUND
CLAMP

ELECTRIC
SERVICE
EQUIPMENT

ANTENNA
DISCHARGE  UNIT
(NEC  SECTION  810-20)

GROUNDING  CONDUCTORS
(NEC  SECTION  810-21)

GROUND  CLAMPS

POWER  SERVICE  GROUNDING
ELECTRODE  SYSTEM
(NEC  ART  250,  PART  H) 

NEC - NATIONAL  ELECTRICAL  CODE

12.

Power-Cord Protection – Power-supply cords should be
routed so that they are not likely to be walked on or
pinched by items placed upon or against them, paying
particular attention to cords at plugs, convenience
receptacles, and the point where they exit from the
appliance.

14.

Cleaning – The appliance should be cleaned only as
recommended by the manufacturer.

15.

Power Lines – An outdoor antenna should be located away
from power lines.

16.

Outdoor Antenna Grounding – If an outside antenna is
connected to the receiver, be sure the antenna system is
grounded so as to provide some protection against voltage
surges and built-up static charges. Article 810 of the
National Electrical Code, ANSI/NFPA 70, provides
information with regard to proper grounding of the mast
and supporting structure, grounding of the lead-in wire to
an antenna-discharge unit, size of grounding conductors,
location of antenna-discharge unit, connection to grounding
electrodes, and requirements for the grounding electrode.
See Figure A.

17.

Nonuse Periods – The power cord of the appliance should
be unplugged from the outlet when left unused for a long
period of time.

18.

Object and Liquid Entry – Care should be taken so that
objects do not fall and liquids are not spilled into the
enclosure through openings.

19.

Damage Requiring Service – The appliance should be
serviced by qualified service personnel when:
A. The power-supply cord or the plug has been damaged;

or

B. Objects have fallen, or liquid has been spilled into the

appliance; or

C. The appliance has been exposed to rain; or
D. The appliance does not appear to operate normally or

exhibits a marked change in performance; or

E. The appliance has been dropped, or the enclosure

damaged.

20.

Servicing – The user should not attempt to service the
appliance beyond that described in the operating
instructions. All other servicing should be referred to
qualified service personnel.

21.

Internal/External Voltage Selectors – Internal or external
voltage selector switches, if any, should only be reset and
re-equipped with a proper plug for alternative voltage by a
qualified service technician. Do not attempt to alter this
yourself.

Содержание DP-DJ101

Страница 1: ...wing the provisions of 73 23 EEC 89 336 EEC and 93 68 EEC Directive BEREINSTIMMUNGSERKL RUNG Wir erkl ren unter unserer Verantwortung da dieses Produkt auf das sich diese Erkl rung bezieht den folgend...

Страница 2: ...e this unit c Move this unit away from others d Plug this unit respectively into a different AC outlet This is note in accordance with Section 15 838 of the FCC Rules FOR U S A CANADA MODEL ONLY CAUTI...

Страница 3: ...810 21 GROUND CLAMPS POWER SERVICE GROUNDING ELECTRODE SYSTEM NEC ART 250 PART H NEC NATIONAL ELECTRICAL CODE 12 Power Cord Protection Power supply cords should be routed so that they are not likely...

Страница 4: ...ower cord when not using the set for long periods of time Wenn das Ger t eine l ngere Zeit nicht ver wendet werden soll trennen Sie das Netzka bel vom Netzstecker D brancher le cordon d alimentation l...

Страница 5: ...range of 12 using a pitch slider A pitch on off button lets you return to the normal speed of rotation at the touch of a button 3 2 stage braking speed You can select one of two record stop times 4 7...

Страница 6: ...nds y Target light Press the button to the right and a light will pop up directed at the stylus position u Headshell Attach the cartridge here When installing a cartridge refer to the installation ins...

Страница 7: ...terminal SIGNAL GND Connect the ground wire of the included connecting cord here See page 8 7 Power terminal AC IN Connect the connector side of the included AC cord here See page 8 AC IN REMOTE PHON...

Страница 8: ...s 4 Connect the ground wire provided on the pin plug cord to the amplifier s or mixer s ground terminal SIGNAL GND 5 Connect the connector side of the power cord to the set s power connector terminal...

Страница 9: ...Turning speed 33 1 3 45 and 78 rpm Wow flutter 0 2 wrms or less S N ratio 50 dB or greater Platter Aluminum die cast 330 mm diameter Motor Brush less DC motor 2 Tone arm Arm type Static balance S shap...

Отзывы: