3.6.4. Clearing the Protection History
There are two ways to clear the protection history.
(1) Start Protection History Display Mode. Press the button "
STATUS
" to display the protection history. Press and hold the
button "
DIMMER
" for 3 seconds.
FLD
P R T : D C
Press and hold the button "
DIMMER
" for 3 seconds.
FLD
P R T : C L E A R
The above is displayed and the protection history is cleared.
FLD
N O
P R O T E C T
(2) Initialize this unit. ( "See "
Initializing This Unit
"
10 page
)
b
Use the method in
3.6.3.(1)
if you do not want to erase your settings from this unit.
Warning Displays by POWER LED
If the power is turned off while a protection is detected, the POWER LED (red) flashes in the following ways as a warning
according to the protection status.
(1) ASO/DC protection: Flashes in 0.5-second cycles (0.25 seconds lit, 0.25 seconds unlit)
(2) THERMAL (A/B/E/F) protection: Flashes in 2-second cycles (1 second lit, 1 second unlit)
(3) CURRENT protection: Flashes in 4-second cycles(2 second lit, 2 second unlit)
3.7. 232C Standby Clear Mode
3.7.1. Actions
232C Standby Clear Mode :
Switches from 232C standby mode to normal standby mode.
Starting up
Press the "
STATUS
" button during the following display to switch to normal standby mode.
FLD
3 . R S 2 3 2 C
R E S E T
61
Содержание AVR-X3100W
Страница 8: ...Personal notes 8 ...
Страница 26: ...Personal notes 26 ...
Страница 174: ...MX25L1606EM2I 12G DIGITAL IC253 MX25L1606EM2I 12G Block Diagram 8 PIN SOP 200mil 150mil BLOCK DIAGRAM 174 ...
Страница 180: ...NJW1194A INPUT IC484 BLOCK DIAGRAM 180 ...
Страница 181: ...2 FL DISPLAY FLD 018BT021GINK FRONT FL601 PIN CONNECTION GRID ASSIGNMENT q T7 181 ...
Страница 182: ...ANODE CONNECTION 182 ...