Error
Code
Details of Error code
Display
Coping strategies
12
Abnormal data in Update Packet
received from CX870 (PacketNo-
Error).
U p d a t i n g
f a i l
1 2
Turn on the power again. Update will
start automatically.
13
Block Erase failed before rewriting
Main.
E r a s e
f a i l
1 3
Turn on the power again. Update will
start automatically.
14
Block Write failed while rewriting
Main.
U p d a t i n g
f a i l
1 4
Turn on the power again. Update will
start automatically.
15
Error in Verify after rewriting Main
(Check SumError).
U p d a t e C h e c k N G
1 5
Turn on the power again. Update will
start automatically.
16
Setup failure of the transfer
method of XModem.
U p d a t i n g
f a i l
1 6
Check the network connection. Update
in an environment where there is a
small network load.
20
SBL Mode after IP Address acqui-
sition failure (AutoIP).
C o n n e c t i o n F a i l 2 0
Check the network connection. Update
in an environment where there is a
small network load.
21
SBL Mode after IP Address acqui-
sition failure (Time Out).
C o n n e c t i o n F a i l 2 1
Check the network connection. Update
in an environment where there is a
small network load.
22
Login incorrect notification SBL
Mode after DPMS connection.
L o g i n
f a i l e d
2 2
Initialize the unit and try updating
again.
Update in an environment where there
is a small network load.
23
Server congestion notification SBL
Mode after DPMS connection.
S e r v e r
i s
b u s y 2 3
Update in an environment where there
is a small network load.
24
Connection failure notification
SBL Mode after DPMS connection.
C o n n e c t i o n F a i l 2 4
Check the network connection. Update
in an environment where there is a
small network load.
25
Failed to transit to SBL Mode.
C o n n e c t i o n F a i l 2 5
Initialize the unit and try updating
again.
26
Error in Firmware Download (Time
Out).
D o w n l o a d
f a i l
2 6
Check the network connection. Update
in an environment where there is a
small network load.
27
Failed to write to EEPROM after
SBL Mode.
D o w n l o a d
f a i l
2 7
Initialize the unit and try updating
again.
36
Login incorrect notification DPMS
connection.
L o g i n
f a i l e d
3 6
Update in an environment where there
is a small network load.
37
Server congestion notification by
DPMS connection.
S e r v e r
i s
b u s y 3 7
Update in an environment where there
is a small network load.
38
Connection failure notification
DPMS connection.
C o n n e c t i o n F a i l 3 8
Check the network connection. Update
in an environment where there is a
small network load.
81
Содержание AVR-X3100W
Страница 8: ...Personal notes 8 ...
Страница 26: ...Personal notes 26 ...
Страница 174: ...MX25L1606EM2I 12G DIGITAL IC253 MX25L1606EM2I 12G Block Diagram 8 PIN SOP 200mil 150mil BLOCK DIAGRAM 174 ...
Страница 180: ...NJW1194A INPUT IC484 BLOCK DIAGRAM 180 ...
Страница 181: ...2 FL DISPLAY FLD 018BT021GINK FRONT FL601 PIN CONNECTION GRID ASSIGNMENT q T7 181 ...
Страница 182: ...ANODE CONNECTION 182 ...