When the results of check item (29) are "the communication results are not OK"
Check item(30).
Check of power supply voltage of
HDMI Tx :
Is the voltage at the test point of each power sup-
ply pin correct? (1.1 V)
The test points are as follows.
Check item(32).
Check the reset of HDMI TX :
Check the waveform .
Is the waveform at the test point TP (
U1039
) correct when power is
turned on?
Check item(31).
Check the power supply voltage.
Check the power supply components (
U1064
) on
the substrate and peripheral pattern.
If there is no problem, remove the HDMI Tx
(
U1039
) from the substrate and measure the volt-
age at the test point of
check item (30)
.
Is the power supply voltage correct? (1.1 V )
Check the power supply voltage.
Checking device. (HDMI Tx)
HDMI Tx (
U1039
) is faulty.
Replace with a new device.
Recheck from
check item (4).
If it does not work, replace the PCB.
Recheck from
check item (4).
If it does not work, replace the PCB.
Replace (
R1882
) and (
R1883
) with new resistors
and check the I2C communication again.
Check item (32)
If the result is not OK, the HDMI
Tx (
U1039
) is faulty. Replace with a new device.
Check the reset circuit between CPU (
U1018
) and
HDMI Tx (
U1039
).
If there is no problem, the HDMI Tx (
U1039
) is
faulty.
Replace with a new device.
The power supply circuit is faulty.
Replace the PCB.
YES
NO
NO
NO
YES
Example of the waveform to be
checked