67
3.5. Errors checking mode (Displaying the protection history)
3.5.1. Specifications
Error mode (Displaying the protection history):
When the set is started up in this mode, the error information is displayed.
3.5.2. About the display on the FL display
When the "STATUS" button is pressed after setting the error (protection history display) mode is set, a history like the one
shown below is displayed, depending on the conditions.
(1) Normal (when there has been no protection incident)
Upper
P R O T E C T
H I S T O R Y
Lower
: N O
P R O T E C T
(2) For ASO (when the last protection incident was ASO protection)
Upper
P R O T E C T
H I S T O R Y
Lower
: A S O
Cause:
The line between speaker terminals is shorted, or speakers with impedance of less than the rated value.
Supplementary information:
As the excess current is detected after operation of the speaker relay, a short on the
speaker terminal and the connected speaker can be identified.
If the power is turned on without correcting the abnormality, the protection function will work about 7 seconds later
and the power supply will be shut off.
(3) For DC (when the last protection incident was DC protection)
Upper
P R O T E C T
H I S T O R Y
Lower
: D C
Cause:
DC output of the power amplifier is abnormal.
If the power is turned on without correcting the abnormality, the protection function will work about 7 seconds later
and the power supply will be shut off.
(4) For THERMAL (when the last protection incident was THERMAL protection)
Upper
P R O T E C T
H I S T O R Y
Lower
: T H E R M A L
*
z
: A, B
Cause:
The temperature of the heat sink is excessive.
If the power is turned on without correcting the abnormality, the protection function will work about 7 seconds later
and the power supply will be shut off.
(5) For CURRENT (when the last protection incident was CUIRRENT protection)
Upper
P R O T E C T
H I S T O R Y
Lower
C U R R E N T
Cause:
Continuous and abnormal output is detected while using speakers with multiple channels.
If the power is turned on without correcting the abnormality, the protection function will work about 1 minute later and
the power supply will be shut off.
b
Additional causes of protection can be due to loose connections, associated components, Microprocessor, etc.
When the "STATUS" button is pressed again after the above protection history as shown above is displayed, the normal
display reappears.(Refer to "PROTECTION DIAGRAM" 33 page.)
Содержание AVR-4520
Страница 32: ...32 Personal notes...
Страница 102: ...102 Personal notes...
Страница 124: ...124 LEVEL DIAGRAM FRONT ch I V I V GAIN ADJ ANALOG ATT SPEAKER OUT REC OUT LEVEL DIAGRAM...
Страница 125: ...125 LEVEL DIAGRAM CENTER ch I V I V GAIN ADJ SPEAKER OUT...
Страница 126: ...126 LEVEL DIAGRAM SUBWOOFER ch I V I V 10dBFS DD IN Config1 GAIN ADJ SPEAKER OUT...
Страница 127: ...127 LEVEL DIAGRAM SURROUND ch I V I V GAIN ADJ SPEAKER OUT...
Страница 128: ...128 LEVEL DIAGRAM SURR BACK ch I V I V GAIN ADJ SPEAKER OUT...
Страница 129: ...129 LEVEL DIAGRAM FRONT HEIDHT ch I V I V GAIN ADJ SPEAKER OUT...
Страница 130: ...130 LEVEL DIAGRAM FRONT WIDE ch I V I V GAIN ADJ SPEAKER OUT...
Страница 131: ...131 LEVEL DIAGRAM ZONE2 3...
Страница 183: ...183 Personal notes Personal notes...
Страница 195: ...195 R5F3650NNFB DIGITAL U2101...
Страница 209: ...209 MX29LV160DBTI 70G NETWORK DSP U0103 U0203 U0303 MX29LV160DBTI 70G Block Diagram...
Страница 213: ...213 AK5358BET DIGITAL U0141 AK5358BET Pin Function...
Страница 218: ...218 ADV7850KBCZ 5 DIGITAL U1102 ADV7850...
Страница 236: ...236 2 FL DISPLAY FLD 17 BT 40GINK SPK SMPS Z6801 PIN CONNECTION GRID ASSIGNMENT Y2 q...
Страница 237: ...237 ANODE CONNECTION...