Denison Hydraulics Jupiter 900 Скачать руководство пользователя страница 12

INSTALLATION DRAWINGS

8

SWITCH AND JUMPER SETTINGS

Back to Content

Содержание Jupiter 900

Страница 1: ...Publ 9 AM683 A replaces 9 AM683 DENISON HYDRAULICS Jupiter 900 Driver Card Panel Mount Version Series S20 14087 0 Design C Back to Content...

Страница 2: ...river S20 14078 which was tested in an EMC TEST Laboratory in Germany The S20 14087 uses the same electronic assembly as the S20 14078 less the Euro style front panel assembly Hence by construction th...

Страница 3: ...ocard version S20 14078 only 4 Added option to permit isolated power source for E STOP function This option is factory set to operate as previous versions If isolated power source is desired move jump...

Страница 4: ...PWM frequency 4 input 4 ramp generator 4 controls indicators 4 emergency stop option 4 soft stop option 5 reverse CMD option 5 ramp at zero option 5 closed loop control 5 procedures 6 installation op...

Страница 5: ...ramp falling range A 0 2 6 sec Negative ramp falling range B 0 8 40 sec OUTPUT DRIVER Pulse width modulation PWM driver with current feedback and short circuit protection PWM frequency 120Hz no jumper...

Страница 6: ...terminals 2 piece construction for quick disconnect Weight 0 22 kg 0 484 Lbs I O CONNECTOR PIN ASSIGNMENTS A2 10V Ref 2 5mA C2 Test Point Command In S20 14087 A4 10V Ref 2 5mA C4 Test Point Ramp Firs...

Страница 7: ...card also features two ranges of positive and negative ramping remote emergency shutdown control options for soft stop emergency stop and reverse command as well as provisions for closed loop control...

Страница 8: ...amp and signal ground EMERGENCY STOP OPTION The emergency stop E stop input controls the K1 relay that provides 24VDC to the output driver stage Applying logic level 15 to 24VDC to the E stop enables...

Страница 9: ...ust the IA min potentiometer until a value of 0 124VDC 0 124A is read on the DVM Apply a negative 3 command signal to the appropriate input Adjust the IB min potentiometer until a value of 0 124VDC 0...

Страница 10: ...INSTALLATION DRAWINGS 6 mm Input 85 264VAC 47 440HZ 0 6 AMP Output 24VDC 1 3 AMPS DIMENSIONS IN INCHES MILLIMETERS Back to Content...

Страница 11: ...INSTALLATION DRAWINGS 7 Back to Content...

Страница 12: ...INSTALLATION DRAWINGS 8 SWITCH AND JUMPER SETTINGS Back to Content...

Страница 13: ...900 DRIVER FUNCTIONAL BLOCK DIAGRAM 9 REVERSE CMD SOFT STOP INVERTED DIP SW1 MARKINGS O OPEN SW1A 1 C CLOSED ON SW1B 2 SW1C 3 SW1D 4 Back to Content...

Страница 14: ...INPUT SIGNAL OPTIONS 10 85 264VAC 47 440HZ Back to Content...

Страница 15: ...INPUT SIGNAL OPTIONS 11 85 264VAC 47 440HZ Back to Content...

Страница 16: ...APPLICATION DIAGRAMS 12 Back to Content...

Страница 17: ...APPLICATION DIAGRAMS 13 COMMAND OUT INVERTED DIP SW1 MARKINGS O OPEN SW1A 1 C CLOSED ON SW1B 2 SW1C 3 SW1D 4 Back to Content...

Страница 18: ...APPLICATION DIAGRAMS 14 COMMAND OUT INVERT Back to Content...

Страница 19: ...APPLICATION DIAGRAMS 15 COMMAND OUT INVERT Back to Content...

Страница 20: ...APPLICATION DIAGRAMS 16 COMMAND OUT INVERT Back to Content...

Страница 21: ...APPLICATION DIAGRAMS 17 COMMAND OUT INVERT Back to Content...

Страница 22: ...APPLICATION DIAGRAMS 18 COMMAND OUT INVERT Back to Content...

Страница 23: ...NOTES 19 Back to Content...

Страница 24: ...Stuttgart Great Britain DENISON HYDRAULICS U K Ltd Kenmore Road Wakefield 41 Industrial Estate Wakefield WF20XE West Yorkshire England Tel 44 19 24 826 021 Fax 44 19 24 826 146 Other sales offices Bur...

Отзывы: