background image

CAUTION (WARNING) 

1.

 

Keep distance between charger and battery (1 meter apart) during charging. 

2.

 

Drop current when temperature of battery during charging rises to about 40 degrees centigrade. 

3.

 

Reduce current adjustment when pointer of the Ampere meter indicate 10A over area (RED zone) 

4.

 

Prevent over filling the electrolyte in the battery as it may over flow. 

5.

 

Before end of normal charging small bubbles may appear from each terminal that is normal. 

6.

 

Additional charging is needed if the battery sulfuric acid specific gravity is under 1.25SG. 

7.

 

Charge once every 2 months if there is no trouble for engine starting. 

8.

 

V is Voltmeter and A is Ampere meter. 

9.

 

Voltmeter indicates charging voltage. Charge 12V battery to be about 15V in normal charging. 

 
PROHIBITION 
1.

 

Use spare fuse when the installed fuse in blown. 

Never use wire or other non-standard rated fuse

. 

2.

 

Do not charge with battery cap ON (CLOSE) 

3.

 

Do not touch the charging clip + & - together. 

4.

 

Do not invert the Positive and Negative charging on the battery terminal. 

(Doing so will activate the 

circuit breaker and may damage the battery)

. 

5.

 

If the connection is set conversely, D.C breaker on the back of the charger will automatically cut off. 

6.

 

Do not take off (Disconnect) the clip +/- or operate the switches during charging. 

7.

 

Do not allow fire or sparks to come near the battery as it can catch fired and explosion occurred due to 
emission of hydrogen when the battery is in charging. 

 
THINGS TO CHECK IF METER DO NOT SWING OR LAMP IS NOT LIGHTED 
1.

 

Completely discharged battery cannot be charge instantly (see No. 3). 

2.

 

Check whether capacity for the fluid (Electrolyte) of each terminal of the battery is full or not. 

3.

 

If Ampere meter do not swing (move), this indicate the Specific Gravity (SG) of the battery electrolyte is 
dropping due to the battery is totally discharged. (In this case set current Ampere meter to No. 2 for 6V 
and to No. 7 for 12V than charge the battery for about 15 hrs) 

4.

 

If after charging for 3hrs at the above and the Ampere meter swing (move), than charge at normal 
charging continuously. 

5.

 

If lamp does not light up, check the fuse in the back of the charger. 

6.

 

When meter does not swing in spite of lamp is ON or Battery is normal, check again the connection of the 
clips and terminals.     

 
 
 
 
 
 
 
 
 
 
This manual contain 4 pages.  
 
 