Refrigerant Safety Data

Reactivity Data

Unstable

Stability

Stable

YES

Conditions to Avoid

Use in presence of naked flames, red-hot surfaces. High moisture levels

Incompatibility (Materials and Conditions to Avoid)

May react violently with sodium, potassium, barium or other alkali or alkaline earth materials.
Magnesium and alloys containing more than 2% magnesium. All finely divided metals.

Hazardous Decomposition Products

Halogen acids formed by thermal decomposition.

Fire and Explosion Hazard Data

Flash Point (

o

C) 

Method

---

---

Auto-ignition Temperature (

o

C)

---

Flammable Limits (% by Vol. in Air)

 

Lower

 

Upper

Non Flammable 

--- 

---

Would any material saturated 

Materials:

with this product be subject to
spontaneous combustion? 

No

Fire Extinguishing Data

Non flammable, not combustible.

Special Fire Fighting Procedures

Fire exposed containers should be kept cool with water sprays.

Usual Fire and Explosion Hazards

Will decompose in contact with high temperature sources, i.e. flames, electric arcs, etc. to produce irritating
and highly toxic acidic products. Breathing apparatus should be worn if refrigerant is exposed to fire
conditions. Containers may burst if overheated.

Precautions in Handling and Use

General Precautions

Atmospheric levels should be minimised and kept as low as reasonably practicable below hygiene standard.
Avoid inhalation of high concentrations of vapour. Heavy vapour collects at low levels. Ventilate by extraction
at lowest level. Decomposes in flames, arcs and at red heat to toxic acid by-products. Avoid contact between
liquid and skin or eyes.

Ventilation Requirements

Ventilation may be required to achieve a sufficiently
low exposure level. Extract at lowest level. Vapour
collects in pits, trenches, basements, sewers and in
confined spaces and vessels.

Respiratory Protection

Where doubt exists on atmospheric concentration and
particularly in confined spaces, self-contained
breathing apparatus should be considered. Breathing
apparatus should always be worn in a fire situation.

Protective Clothes

Where liquid splash is a possibility gloves suitable
for use in low temperatures should be worn e.g.
chlorobutyl rubber with cotton liners.
Overalls.

Eye Protection

Goggles.

Storage

Containers should be stored in a cool dry place away from fire risk and sources of heat. They should not be
exposed to direct radiation from sources of heat such as steam or electric radiators. Do not heat containers
beyond 45

o

C.

Содержание C120-3

Страница 1: ......

Страница 2: ...10 Description of Operation 10 Schematic Flow Diagram 11 General Arrangement Drawings 12 Technical Description of Components 17 Technical Data Tables 18 Electrical Description 20 Wiring Diagrams 22 Co...

Страница 3: ...authorised distributor NOTE This manual applies ONLY to the C series of Compressed Air Dryers For actual model refer to serial plate fitted to the unit For other ranges refer to the respective manual...

Страница 4: ...reaction to sensitive skin Refrigerants contain hydrofluorocarbons HFC s Glycol water mix is used during manufacture but drained before delivery The quantities in use are minimal but care should be t...

Страница 5: ...BEFORE and DURING this operation Proper fire precautions shall be observed and the necessary fire safety equipment on hand typical for electrical oil and foam fires The refrigerant used is refrigeran...

Страница 6: ...itions Containers may burst if overheated Precautions in Handling and Use General Precautions Atmospheric levels should be minimised and kept as low as reasonably practicable below hygiene standard Av...

Страница 7: ...contaminated clothing carefully wash affected areas of skin thoroughly with copious amounts of warm water If symptoms occur obtain medical attention Eyes Irrigate with eyewash solution or clean water...

Страница 8: ...ertures in the dryer as lifting points Position of Unit The dryer should be placed on a firm level load bearing surface of adequate strength and a suitable area be left clear of obstruction at the inl...

Страница 9: ...ine and piped to a suitable oil water separator prior to drain Installation Recommendations The compressed air pipework should incorporate sufficient shut off valves to enable the dryer to be by passe...

Страница 10: ...g controls charging the system evacuating the system or opening the system in any way must be carried out by a FULLY QUALIFIED REFRIGERATION ENGINEER A City and Guilds 2078 or equivalent certificate i...

Страница 11: ...PS1061 C 021...

Страница 12: ...PS1061 C 001...

Страница 13: ...PS1061 C 002...

Страница 14: ...PS1061 C 003...

Страница 15: ...PS1061 C 004...

Страница 16: ...PS1061 C 005...

Страница 17: ...is achieved by a multi bladed propeller type fan directly driven by a single phase motor 4 Hot Gas By pass Valve This valve is installed such that discharge gas may be diverted to the suction line wh...

Страница 18: ...in Connections mm od 8 8 8 8 8 8 Electrical Supply 220 240 volt 1 phase 50 60 Hz Installed Power kW 0 45 0 57 0 66 0 96 0 96 0 85 Full Load Current Amps 2 2 6 3 4 35 4 35 3 9 Refrigerant R134a R407C R...

Страница 19: ...Connections mm od 8 8 8 8 8 Electrical Supply 220 240 volt 1 phase 50 60 Hz Installed Power kW 1 49 1 73 2 01 2 32 2 76 Full Load Current Amps 6 76 7 86 9 16 10 56 12 56 Refrigerant R407C Refrigerant...

Страница 20: ...ompressed air dryers 1 Valve Close Time the time the valve is closed between discharges Variable between 1 20 mins Hold the UP button for 15 seconds The display will start blinking displaying the valv...

Страница 21: ...of the electrical circuitry the following wiring diagrams are included Model Numbers Schematic Wiring Diagram Number C9 1 C14 1 C19 1 PS1061 C 011 C31 2 C39 2 C58 2 PS1061 C 012 C92 3 C120 3 C147 3 P...

Страница 22: ...PS1061 C 011...

Страница 23: ...PS1061 C 012...

Страница 24: ...PS1061 C 013...

Страница 25: ...PS1061 C 014...

Страница 26: ...ing system 5 Dispose refrigerant gas to waste 5 Send used refrigerant gas back for reprocessing Note Disposal of refrigerants must be closely controlled To dispose of refrigerant or a refrigerant syst...

Страница 27: ...tightness of electrical connections Check all wiring for damage to insulation Check running current Clean condensate line strainer Bi annually Check operation of refrigerant circuit including temperat...

Страница 28: ...indicates a value 4C permanently Return the air inlet temperature to within the limits Compressed air flow rate too high The digital display panel indicates a value 4C permanently Correct the air flow...

Страница 29: ...passage as the electronic controller has failed The compressor stops The compressor does not stop even if the digital display panel indicates 0 several minutes Change the electronic board Solenoid va...

Страница 30: ...and fan has invert spin In case 3 phases used The cooling air had pass on fan and refine unit Invert the electric phase E High pressure switch stop working and have to control by manual The refrigeran...

Страница 31: ...Notes...

Страница 32: ...co compressed air equipment can be found in all types and sizes of industry throughout the World from small operator spray booths to major industrial installations With an open flexible approach and a...

Отзывы: