45
21492044.indd/131
107
This parameter defines the time (in seconds) after which the hand-held transmitter
switches from Operating mode into STOP mode (sleep function).
The default value set in the factory is a time period of 1800 sec.
The current time period is shown in the display. To navigate, use the following
keys:
Key Function
Right
Change to display of parameter 007
Left
Change to display of parameter 005
Lift Exit
parameter
programming
menu
F1
Change to entry and selection mode
After changing to entry mode, the colon following the parameter code 006 is re-
placed by an equals symbol. Instead of the current value, the character string
“0——” is displayed. Entry starts with the first character on the left.
Use the Left and Right keys to select the character for the current position. Only
figures 0 – 9 may be used.
Change to the next position by actuating the F1 key.
Following complete, correct entry, confirm the new value by actuating the F2 key.
Entry and the Hand-held transmitter parameter programming menu can be exited
by actuating the Lift key at any time. The parameter will remain unchanged, if the
Lift key is actuated before the entered value has been accepted with F2.
1.8 Displaying and enter-
ing the cut-out time in
Run mode, Parameter
code 006
1.8.1 Display
mode
1.8.2 Entry and selection mode
1.8.3 Selection
of
figures
1.8.4 Changing to the next position
1.8.5 Confirming the new value
1.8.6 Exiting the menu