DEMA TITAN II T-812-DL Скачать руководство пользователя страница 16

I-1024 
Rev. G-43816 

Page 16 of 16 

  3/23/18 

 

 Troubleshooting 

 

 

Symptom Probable 

Cause

Remedy 

No power is being supplied 
to the unit 

1.

 

Trigger Cables connected to the wrong 
place on the machine. 

 

2.

 

Switch on bottom of unit is turned off. 
(Some units may not have a switch) 

3.

 

Power is not cycling on the machine 
properly. 

 

4.

 

Trigger/Power cable is damaged from 
installation. 

1.

 

Check wiring diagram for proper connection and 
contact dish machine manufacturer for correct 
trigger placement. 

2.

 

Make sure switch is turned on. 

 

3.

 

Check with the dish machine manufacturer if all 
power should have been restored to the unit to see 
if there is an issue with the machine. 

4.

 

Turn power to the dish machine off and inspect the 
cable for any possible damage done. 

Pumps are not priming like 
they should be or not 
holding a prime 

1.

 

Hole in the tubing from the chemical 
container to the pump head. 

 

 

2.

 

Hole in the squeeze tube in the pump 
head. 

3.

 

Fitting is not tight on the tubing 

1.

 

Check the tubing from the chemical container to 
the pump head for leaks by feeling the tubing for 
chemical that has leaked out. Replace the tube if 
necessary. 

2.

 

Replace the squeeze tube after inspecting it for a 
possible hole or leak. 

3.

 

Check both the inlet and outlet fitting and tighten if 
necessary to create a good seal. 

Pump over feeding 

1.

 

If in concentration or probe mode, 
feed rate may not be set correctly. 

2.

 

If in concentration or probe mode, 
probe cable may not be connected 
properly. 

3.

 

If a probe is being used, scale could be 
built up on the probe. 

4.

 

Range of set point is too low. 

1.

 

Check the programming for the feed rate. 

 

2.

 

Check the probe cable connection points and make 
sure it is connected properly. 

 

3.

 

Clean Probe. 

 

4.

 

Check set point in programming. 

Pump under feeding 

1.

 

If in concentration or probe mode, the 
probe cable may be shorted. 

2.

 

If a probe is being used, scale would 
be build up on the probe. 

3.

 

Range of set point is too high. 

1.

 

Check the probe cable for any possible shorts and 
correct the issue where necessary. 

2.

 

Clean Probe. 

 

3.

 

Check set point in programming.. 

Rinse/Sanitizer pump not 
running 

1. Speed turned off. 

1. Check the programming to see the speed setting 

 and make sure it is on the proper setting. 

Warranty  

 

Merchandise Returns 

No Merchandise will be Returned for Credit Without DEMA’S Written Permission. Returned Merchandise 
Authorization Number is Required in Advance of Return. 

 

Product Warranty 

DEMA products are warranted against defective material and workmanship under normal use and service 
for one year from the date of manufacture.  This limited warranty does not apply to any products that have 
a normal life shorter than one year or failure and damage caused by chemicals, corrosion, physical abuse, 
or misapplication. Rubber and synthetic rubber parts such as “O”-rings, diaphragms, PVC tubing, and 
gaskets are considered expendable and are not covered under warranty. This warranty is extended only to 
the original buyer of DEMA products. If products are altered or repaired without prior approval of DEMA, 
this warranty is void. Defective units or parts should be returned to the factory with transportation prepaid. 
If inspection shows them to be defective, they will be repaired or replaced without charge, F.O.B. factory. 
DEMA assumes no liability for damages. Return merchandise authorization number must be granted in 
advance of returned units for repair or replacement (See “Merchandise Returns” above). 

Содержание TITAN II T-812-DL

Страница 1: ...form to loca icating tee is to state of Wiscon OTECTIVE CL CTS WAREW T 813 S elivery functio ply that will acc of 20V 500V 5 as an Auto Sw ver feature virtu meet all applica incial or other ctrical co...

Страница 2: ...8 ID LDPE detergent 16 ft x 1 16 ID Vinyl rinse san 1 1 1 1 1 2 1 2 C 12V1K Conductivity Cell 1 1 1 1 904 8KY Sanitizer Check Valve 1 1 Operational Requirements For Indoor Use Only Main Power 100 VAC...

Страница 3: ...M MAGNE INDUCT 6 PRODU POWER OWN RIPTION ROL BOARD ER BOARD W R SUPPLY inc TING BRACK II HOLE PLU PUMP AND M II LABEL KIT ER CABLE R E CABLE 15 MODULE AS R AND DETE NOID VALVE ER INPUT C MODULE JOIN...

Страница 4: ...R BLO 2 ROLLER BLO ENT SQUEEZE TU ITIZER SQUEEZE PU 60 RPM GEAR 15 RPM GEAR MO SILICONE LUBE VE ASS DES SOLENOID VA DES VAL MACHINE S VALVE ASSEMB G FITTING STRA PP JG FITTING ELB SS SCR CABLE VALVE B...

Страница 5: ...le ng 25 68 20 i 0 12 SV1 whic quired and if d needed to go fr length require e elp to install th fety purposes per the dish m ROUNDED E nnection points rd and cable T he wiring diagra field when the...

Страница 6: ...WH BLA RED GRE ing of the unit with DEMA E three steps wil rogrammed in hine manufactu dish machine p via the wash nd white wire n should receiv wires to the dis a rinse trigger OWN WASH ITE WASH ACK...

Страница 7: ...oncentration pr ess mode settin settings simula ount of time in mount of time ften to recharg ode for less than 2 ge harge is 1 min o 8 s it will appear ht Use and to step throug within 10 seco page 1...

Страница 8: ...is onds to 10 min rom when the c It may be set f detergent will b ed This time is 5 min The def R SOON M This allows Auto Switch switches fro Setting it to This allows the isplayed when Enter display...

Страница 9: ...ting and the deterge prompts t one pressing nductivity A c chemical capsu asure the condu fficiently differ the same a fai The set point sh ed to be about be recommend rinse motor m t The default i fr...

Страница 10: ...nt cover of the dispenser Take the four screws out to lift the board out There are two solder points on the back of the board Connect them together with an insulated wire and turn on the power Next tu...

Страница 11: ...tion r three minute cle will termina ESS allows yo NOTE T directly t heading Press the headi programm m Access programmable G PRESS GET TO THE es RIME PRIMING mp if it is not s PRIME PRIMIN ZER PRIMIN...

Страница 12: ...uto S SWITCH ACTIVE MACHIN DOOR TRIGGE NO TRIG vailable DETE se trigger Rins ENT ONLY re inse runs with t trigger NO TR power to the d DIRTY H ACTIVE ays the current and hold down NTER USER CO DEMA St...

Страница 13: ...ow the block RETURN TO SYSTEM ACCESS RINSE SPEED 50 0 100 RINSE DELAY 1 0 15s RINSE LIMIT 15 70s RINSE LENGTH The length of the rinse cycle for one rack 12 5 75s PROBELESS PARAMETERS 1 0 10 DWELL TIME...

Страница 14: ...OTE 0000 0000 LEFT TO RESET RETURN TO SYSTEM ACCESS NOTE This screen displays the total switchover count for OVER and UNDER feedings The number below OVER is the count of switchovers caused by the dis...

Страница 15: ...ult for this initial charge is 15 seconds This may not be enough time for the wash tank to reach its concentration level Watch the wash tank reach its level and determine the time it takes then use th...

Страница 16: ...the probe cable connection points and make sure it is connected properly 3 Clean Probe 4 Check set point in programming Pump under feeding 1 If in concentration or probe mode the probe cable may be s...

Отзывы: