I-1048
Page 5 of 7
Rev. A-39406 11/27/13
A. Press the reset button before programming.
Note: If a mistake is made during the programming, simply push the reset button
and start over.
B.
12 Hour or 24 Hour (Military) Mode
1.
Hold the “Clock” button down for 5 seconds or more to change back & forth to
between the 12 & 24 hour modes.
C.
Set
the
Time
and
Day
When the unit arrives the display may be blank or may display a time. Insert the (8) D-Cell
batteries into the dispenser and that will provide power to the timer.
NOTE: Make sure that the indicator bar in the bottom of the display is over the word
OFF. Press the MANUAL button until it is in the off position.
1.
To set the time and day of the week, press and hold the CLOCK button and press the day,
hour, and minute buttons until the proper day, hour, and minute is achieved.
Note: The days will be across the top of the screen and will advance as the button is
pressed. The time must be set to AM or PM. Pressing in the Day, Hour, or Minute
button for three seconds will advance the setting until the button is released.
C.
Programming the Dispensing Events: Up to 8 independent dispensing events can be
programmed
1.
Press and release the TIMER button to enter the programming mode. The event number
will be in the bottom left corner.
Note: To program a full event, a pump start time and
stop time will need to be programmed.
NOTE: THE PUMP WILL RUN FOR 23 HRS 59 MIN NO SOP TIME HAS BEEN
SET.
a)
Press the “DAY” button until the desired days are shown.
b)
Press the “HOUR” and “MINUTE” buttons until the time is reached when the pump
should start.
Note: AM or PM in top left corner of screen.
2.
Press and release the TIMER button again to move to programming the pump stop time.
a)
This setup will be used to turn the pump off. Use
the table to determine the pump run time.
b)
Press the “DAY” button until the days match the
days programmed in the pump start portion of the
programming.
c)
Press the “HOUR” and “MINUTE” buttons until
the desired run time is reached.
3.
To program another event, press TIMER button
again for Programs 2-8 and follow Programming
Steps 1 and 2 above. Every START function needs a
corresponding STOP function in order to stop the pump.
4.
When finished programming, push the CLOCK button again to return to time of day
(normal) display.
D. Priming the Pump
RUN
TIME
AMOUNT
DISPENSED
ml oz
1 min
110 ml
3.5 oz
3 min
~295 ml
~10 oz
5 min
550 ml
17.5 oz
6 min
~590 ml
~20 oz
10 min
1100 ml
35 oz
20 min
2200 ml
70 oz