background image

ALARM SIGNAL & LED INDICATION

Note : ■■■ represents “beep, beep, beep”

Detector 

Operation

Green

Red

Yellow

Alarmsignal

Power indication

Alarm signal

Fault signal

Normal Operation

Flash once per 

minute ¤

-

-

-

Alarm Condition

-

4 beeps + flash ¤

-

■■■■ -1s -■■■■ 

-1s -■■■■ …

Silence (hush) mode 

under  

alarm condition

-

4 flashes ¤

-

-

Interlink signal 

input (slave)

-

beep + flash ¤

-

■■■■■■■……….

To activate 

silence(hush) unit 

under interlink 

signal input

-

Flash ¤

-

-

Pre-alarm warning 

CO level (40 ppm 

or greater level 

detected)

-

Flash once every 

8 seconds until 

alarm ¤

-

-

Memory function- 

indicates the alarm 

has been activated 

before(not from 

test button) due to 

whatever reason

-

-

-

■--8s--■--8s--■

1 beep every 8 

seconds last for 12 

hours. Press button 

once to reset to 

normal mode

Low Battery 

Warning

-

-

1 beep + flash 

every minute ¤

■-1 min-■-

1min-■…….

Sensor Fault

-

-

2 beeps + 

flash every 8 

seconds ¤

■■-8s-■■-8s-■■-

8s-…………

End of sensor 

lifetime warning

-

-

3 Beeps + 

flash every 

minute ¤

■■■-1min-■■■-

1min-■■■……

Temporary delay 

warning signal – 

(Push button to 

temporarily disable 

low battery- or end 

of life- warnings for 

12 hours)

-

Flashes 3 times 

after a push of the 

button

¤ 

(Push button 

again to return to 

warning mode at 

any time)

-

-

Содержание CN-1231

Страница 1: ...its Do not expose to rain or moisture The detector will not protect against risk of carbon monoxide poisoning when the battery is flat Do cover the alarm when decorating REMEMBER to uncover the unit when decoration is finished excessive fumes from paints solvents cleaning agents etc may damage or deteriorate sensor The CO alarm shall not be seen as a substitute for proper servicing of fuel burning...

Страница 2: ... as headaches tightness of chest dizziness fatigue confusion and breathing dif ficulties Because CO poisoning often causes a victim s blood pressure to rise the victim s skin may take on a pink or red cast Extreme exposure to CO can cause brain damage death WARNING EXPOSURE TO HIGH LEVELS OF CARBON MONOXIDE CAN BE FATAL OR CAUSE PERMANENT DAMAGE AND DISABILI TIES COMMON RISKS FOR CO POISONING Tech...

Страница 3: ...ting bracket 1 by pushing it upwards and then fasten it onto the ceiling wall with the enclosed screws Connect the battery with ve 2 and ve in the correct position and close the battery cover Connect snap contact to relay 3 base and all connecting wires through the cable entry Fix CO alarm to the relay base 4 with the screws provided Hook the relay base on bracket 5 until it locks in place Now tes...

Страница 4: ...ower CO alarm is an early warning device no more no less DO NOT PAINT the alarm WHERENOTTOINSTALLCOALARM Within 1 5m 5 feet of any gas appliance as furnace In any high level of dusty dirty or greasy area In damp or very humid areas outdoor room or next to bathroom at least installed the alarm 3 meters 10 feet away from the bathroom In very cold or very hot area where the temperature could not be l...

Страница 5: ...attempt to repair it yourself warranty will be void Note The test push button is independent function with hush button During the normal testing mode the silence feature will not active ADDITIONAL FEATURES The CO alarm comes with the following friendly additional features for use Silence feature This feature can be used to silence nuisance alarms Press test silence button during alarm condition wi...

Страница 6: ... function by pressing the test push button until an alarm sounds Self diagnostics Automatically check the sensor every 8s to ensure of correct operating of alarm Low battery warning When the battery power deteriorated the unit will emit one beep with Yellow LED flash every minute to remind user to replace battery Fault warning If a fault is detected the unit will emit 2 beeps with Yellow LED flash...

Страница 7: ... 50 ppm 60 min 90 min 100 ppm 10 min 40 min 300 ppm 3 min The battery lasts for over one year About a month before the battery is com pletely flat the alarm emits a short signal with Red LED flashes every minute This is the signal that the battery needs replacement The alarm works as nor mal during this time Always test the alarm after changing the battery Replace battery with GP1604A Duracell MN1...

Страница 8: ...detected Flash once every 8 seconds until alarm Memory function indicates the alarm has been activated before not from test button due to whatever reason 8s 8s 1 beep every 8 seconds last for 12 hours Press button once to reset to normal mode Low Battery Warning 1 beep flash every minute 1 min 1min Sensor Fault 2 beeps flash every 8 seconds 8s 8s 8s End of sensor lifetime warning 3 Beeps flash eve...

Страница 9: ... applies if the alarms is used in the normal way and is serviced regularly The obligations of this warranty at our discretion shall be limited to the repair or replacement of any part of the alarm and is also conditional on the CO Alarm s not having been tampered with modified or subject to attempted repairs Your statutory rights as a customer are in no way compro mised by this Warranty Limitation...