![DELTACALOR Bis Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/deltacalor/bis/bis_instructions-manual_2478780014.webp)
Stendy
•
Stendy Elegance
•
Stendy Short
•
Bis
•
Tris
45
Correct area for installation (verify the standard applied in UK) (Fig. 1)
The particular conditions of vulnerability to which it is subject the person located in the bathroom lead to consider this environment, from the
electrical point of view, the most dangerous in the apartment. Depending on the hazard, in bathrooms and shower rooms there are four areas (see
pic. 1) which can determine the selection of criteria and installation of components and users:
Zone Definition
Possibility of installation
Mixed radiators
without plug “F”
Mixed radiators with plug “T” or
with electrical resistance only
0
Corresponds to the volume inside the bath or shower.
No electrical equipment can be installed in this volume.
NO
NO
1
It consists of the volume delimited by the surface which
extends vertically from the bathtub or shower-tray
up to a horizontal level situated at 2.25 m above the
floor. The zone 1 also extends beneath the bathtub.
No electrical equipment can be installed in this volume.
NO
NO
2
It corresponds to the volume surrounding zone
1 which develops vertically, in parallel and at a
horizontal distance of 0.6 m from zone 1, up to
a height of 2.25 m from the floor level.
Devices in class I & II can be installed provided that
the switch or other control devices are not available
from the shower or bathtub and that there is a switch
with differential of idn <30ma. IPX4 (IP24, IP44).
YES
YES
(install the socket for the electrical
connection inside the zone 3)
3
Volume delimited by the vertical surface that can
extend horizontally next to the zone 2 to 2.4 m and
vertically up to a height from floor level of 2.25 m.
Devices in class I & II can be installed provided
that the switch or other control devices are not
available from the shower or bathtub and that there
is a switch with differential of idn <30ma. IPX1.
YES
YES
WARNING
•
Please refer to the electric resistances recommended for sizing. It is allowed to
choose a smaller size resistance but NEVER a bigger resistance than the ones
specified. This choice will automatically VOID the warranty.
•
It is recommended to use electrical components (resistances and thermostats)
illustrated in Deltacalor catalogue.
WARNING -
The ignition of the heating element to any one of the four
configurations illustrated requires as prerequisite the presence in the radiator, which
is connected to the heating system, of the heat transfer fluid and that one of the
valves is open (recommended holder valve closed and other valve open).
60 cm
225 cm
300 cm
60 cm
60 cm
Zona
Zone
Bereich
3
Zona
Zone
Bereich
2
Zona
Zone
Bereich
1
Fig./Bild 1