background image

Delta Commercial Faucet Limited Warranty

All parts of the Delta® HDF® and TECK® faucets are warranted to the original consumer purchaser to be free from defects in material, finish 
and workmanship for a period of five (5) years unless otherwise specifically stated in the catalogue and price book.  This warranty is made to 
the original consumer purchaser and shall be effective from date of purchase as shown on purchaser’s receipt.

Delta will, at its option, repair or replace, FREE OF CHARGE, during the warranty period, any part which proves defective in material or 
workmanship under normal installation, use and water and service conditions.  If Delta Faucet concludes that the returned part was 
manufactured by Delta Faucet and is, in fact, defective, then Delta Faucet will honour the warranty stated herein.  Replacement parts can be 
obtained from your local dealer or distributor listed in the telephone directory or by returning the part along with the purchaser’s receipt to 
our factory, TRANSPORTATION CHARGES PREPAID, at the address listed.  THIS WARRANTY IS THE ONLY EXPRESS WARRANTY MADE BY DELTA.  
ANY CLAIMS MADE UNDER THIS WARRANTY MUST BE MADE DURING THE FIVE YEAR PERIOD REFERRED TO ABOVE.  ANY IMPLIED WARRAN-
TIIES, INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO 
THE DURATION OF THIS WARRANTY.  LABOUR CHARGES AND/OR DAMAGE INCURRED IN INSTALLATION, REPAIR OR REPLACEMENT AS WELL 
AS INCIDENTAL AND CONSEQUENTIAL, SPECIAL, INDIRECT OR PUNITIVE DAMAGES CONNECTED THEREWITH ARE EXCLUDED AND WILL NOT 
BE PAID BY DELTA FAUCET.

Some states do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential 
damages, so the above limitations or exclusions may not apply to you.  This warranty gives you specific legal rights, and you may also have 
other rights which vary from state to state.

This warranty is for commercial products only from Delta Faucet Company and Delta Faucet Canada (a division of Masco Canada Limited) 
and is void for any damage to this faucet due to misuse, abuse, neglect, accident, improper installation, any use in violation of instructions 
furnished by Delta Faucet or any use of replacement parts other than genuine Delta parts.

Delta Faucet Canada, a division of Masco Canada Limited

350 South Edgeware Road, St. Thomas, Ontario, N5P 4L1

1-800-567-3300 (English)    1-800-265-9245 (French)

Delta Faucet Company

Box 40980, 55 East 111th St., Indianapolis, IN, U.S.A. 46280

(317) 848-1812

www.deltacommercialfaucets.com

Page 8

210398   Rev. A

For further technical assistance, call Delta Commercial Technical Service at 1-800-387-8277 (Canada) or 1-877-509-2680 (U.S.A.).

This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions:

(1) this device may not cause harmful interference, and 

(2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE:

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.  These limits

are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This 

equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may 

cause harmful interference to radio communications.  Operation of this equipment in a residential area is likely to cause harmful interference in which

case the user will be required to correct the interference at his own expense.

Warning:

Changes or modifications not expressly approved by Delta could void the user’s authority to operate the equipment.

CAN ICES-3 (A) / NMB-3(A)  

    

 

 

 

 

 

© 2016 Masco Corporation of Indiana

Содержание TECK 81T2 -WHSHWA Series

Страница 1: ... Brass Renewable Seat for previous Flush Valve models ordered separately 31 3 9a 8a 9b 10c PLEASE LEAVE this M I Sheet with the owner maintenance plumber etc as items relating to ongoing maintenance suggestions and procedures are included Nut Fibre Washer Rubber Washer Slip Joint Nut Installation Filter Screen 29 24VAC 6 4 VDC 12 36 3 5 6 4 30a 30b For valves manufactured after October 2014 0 5L 1...

Страница 2: ...s 4 1 2 x 4 1 2 114 mm x 114 mm shown Stainless Steel Cover with Studs Screws 4 pieces No 6 32 x 2 flat head Stainless Steel Screws Security Spanner Bit package for 4 1 2 114 mm Cover Sensor Module Urinal Flush Valve Sensor Module Water Closet Flush Valve Regulating Screw O Ring Cover Gasket 3 pkg Poppet Pin Pack 3 pkg also see 10b see Table 1 on page 1 Washer 3 pkg required for 6 0 4 8 4 2L Valve...

Страница 3: ...installation This assures SMOOTHER OPERATION of the valves and longer life for the working parts 114mm 4 1 2 114mm 4 1 2 B 121mm 13mm 4 75 44 71mm 2 81 76mm 3 0 VACUUM BREAKER TUBE 38mm 1 5 38mm 1 5 SLIP JOINT NUT WASHERS SUPPLIED 152 mm 6 0 70mm 2 75 114mm 4 5 114 mm 4 5 71mm 2 81 64mm 2 5 VACUUM BREAKER TUBE 19mm 0 75 19mm 0 75 SLIP JOINT NUT WASHERS SUPPLIED Fig 1 D 25mm 1 38mm 1 1 2 Cover Tube...

Страница 4: ...X4 stainless steel plate with bushing to the junction box Assemble cover onto flush valve cap and attach using 2 vandal proof screws provided Ensure the tube assembly is aligned with the slot in the back of the cover If the factory default settings for the sensor are not suitable refer to Step 6 for sensor adjustments Attach sensor plate to the box using the 4 vandal proof screws provided STEP 1 R...

Страница 5: ...r copper sweat with adaptor supplied Sensor Box 102 x 102 x 51mm 4 x 4 x 2 Junction Box C L Centerline Stainless Steel Coverplate Sensor Box 102 x 102 x 51mm 4 x 4 x 2 of sensor box 152mm 6 70mm 2 75 sensor 44mm 1 3 4 from centreline of stop 44mm 1 3 4 from centerline of stop Hardwire Junction Box and Sensor Rough In See Fig 1 for placement of inlet stop NOTE Hardwire juction box installed behind ...

Страница 6: ...e electronic override button until the lights loop back around to a setting that is one less the previous setting Once again verify that the sensor is not detecting the water closet door If not the sensor is now set at your desired position The sensing distance for water closets can be set between 24 and 56 and for urinals between 12 and 28 If all adjustments have been completed press and hold dow...

Страница 7: ...ove the water main etc We strongly recommend that pipe size calculations be done to insure proper water supply sizes Flushometers do NOT provide a water supply they are merely automatically timed self closing valves The inlet supply piping is the water reservoir that must supply sufficient water volume in a short period of time 4 to 10 seconds to properly flush and clear the fixture CONTINUOUS FLU...

Страница 8: ...is warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty is for commercial products only from Delta Faucet Company and Delta Faucet Canada a division of Masco Canada Limited and is void for any damage to this faucet due to misuse abuse neglect accident improper installation any use in violation of instructions furnished by Delta Fa...

Отзывы: