MODELS
SIG80 / SIG80M / SIG110 / SIG110H / SIG110D
Page 3.
3.
Connect wiring
3-1. Follow all local electrical and safety codes.
3-2. NEVER place a switch where it can be reached from a tub or shower.
3-3. Connect wires as shown in wiring diagrams.
Single Spee d Models: SIG80, SIG110
Motion Model: SIG80M
OFF
ON
L
N
POWER SWITCH
JUNCTION BOX
SWITCH BOX
WHITE
BLACK
GREEN
GRD
BLACK
ON/OFF SWITCH
(purchase separately)
SWITCH BOX
120 VAC
LINE IN
WHITE
GROUND
(bare)
POWER
SWITCH
WIRING
PLATE
Humidity Model: SIG110H
Dual Speed Model: SIG110D
HI
POWER SWITCH
MODE SWITCH
JUNCTION BOX
SWITCH BOX
WHITE
BLACK
OFF
ON
WHITE
BLUE
GREEN
GRD
L
N
L
N
ON/OFF SWITCH
(purchase separately)
SWITCH BOX
120 VAC
LINE IN
WIRING
PLATE
BLACK
WHITE
GROUND
(bare)
BLUE
MODE
SWITCH
POWER
SWITCH
3-4. Using wire nuts (not provided ), connect the house power cable to the
ventilating fan wires.
3-5. 14 AWG (2.1 mm
2
) is the smallest conductor that shall be used for
branch-circuit wiring.
4.
Grille attachment
4-1. Insert the motion sensor unit into the grille (Fig. G) (only for SIG80M)
4-2. Insert the mounting springs into the slots and mount the grille to the
body. (Fig. H)
Celling
Sensor unit
Grille
Fig. G
Slots
Spring
Fig. H
5.
Operation
Delay time control
(SIG80M & SIG110D)
or Humidity preset control
(SIG110H).
SIG110H
SIG110D
SIG80M
Low speed air volume
preset control (SIG80M,
SIG110H, SIG110D).
control options
Single Models: SIG80, SIG110
5-1. Single spee d control mode: Turn the POWER switch on to operate at
single speed mode - the LED indicator will be green.