Delta SIG80 Скачать руководство пользователя страница 4

                                                                         

                                       

 

 

 

 

 

 

MODELS 

SIG80 / SIG80M / SIG110 / SIG110H / SIG110D 

Page 4. 

Motion Model: SIG80M  
5-2. Motion control mode: Turn the POWER switch on to operate at motion 

control mode. When motion is detected, the fan will ru n at full speed 
and the LED indicator will be amber. When motion is not detected, the 
fan will continue to run at the full speed until the user -adjustable time 
delay has elapsed, and then will automatically change to the 
user-adjustable low speed airflow.  The LED indicator will be green.  

Factory setting: low speed airflow 40CFM, time delay 15 minutes.  

Humidity Model: SIG110H  
5-3. Humidity control mode: Turn the POWER switch on to operate at 

humidity control mode  - the LED indicator will be blue. When the 
ambient humidity is higher than the user -adjustable set -point, the fan 
will run at full speed. When the ambient humidity is lower than the 
set-point, the fan will continue to run at the full speed until  a 10- 
minute time delay has elapsed, and then will auto matically change to 
the user-adjustable low speed airflow.  

5-4. Full speed mode: Turn the MODE switch on to operate at full speed 

mode - the LED indicator will be amber.  

5-5. Humidity tolerance is about ±10%. Long -time operation will influence 

the detectin g precision as dust accumulates.  The humidity switch may 
need to be adjusted.  

Factory setting: low speed airflow  60CFM, humidity 60%RH.  
 

Dual Speed Model: SIG110D  
5-6. Low speed control mode: Turn the POWER switch on (MODE switch is 

off) to operate at the  user-adjustable low speed airflow  - the LED will 
be green.  

5-7. Full speed control mode: Turn the POWER switch & MODE switch on to 

operate at full speed mode  - the LED indicator will be amber. When the 
user turns the MODE switch off, the fan will continue  to run at the full 
speed until the user -adjustable time delay has elapsed, and then will 
automatically change to the user -adjustable low speed airflow. The 
LED indicator will be green.  

Factory setting: low speed airflow  60CFM, time delay  15 minutes. 

 

MAINTENANCE WARNING: 

Disconnect the power source before working on the unit. Routine 
maintenance must be done every year.  

CAUTION: 
1.

 

Never use gasoline, benzene, thinner or any other such chemicals to 
clean the ventilating fan.  

2.

 

Do not allow water to enter the mot or. 

3.

 

Do not soak resin parts in water over 60°C (140°F).  

CLEANING 
1.

 

Pull down the springs to remove the grille.  

2.

 

Wash and clean the grille. (Use non -abrasive kitchen detergent and 
wipe dry with a new cloth.)  

3.

 

Remove dust and dirt from the ventilating fan.  

4.

 

Using a cloth dampened with non -abrasive kitchen detergent, remove 
any dirt from ventilating fan. Wipe dry with a new cloth.  

5.

 

Replace the grille.  

 
 
 
 

DIMENSION

SPECIFICATIONS

 

Model No.  

Voltage  

(V) 

Frequency  

(Hz) 

Power 

@ 0.1”SP 

(W) 

Air Flow 

@ 0.1”SP 

(CFM) 

Weight 

(lb.) 

Power   

(W) 

Note 

SIG80 

120 

60 

8.2 

80 

10 

18.0 

Single Speed  

SIG80M 

120 

60 

8.2 

80 

10 

18.0 

Motion Sensor  

SIG110 

120 

60 

12.7 

110 

10 

23.0 

Single Speed  

SIG110H  

120 

60 

12.7 

110 

10 

23.0 

Humidity 

Sensor  

SIG110D  

120 

60 

12.7 

110 

10

23.0 

Dual Speed  

Note: Design and specifications subject to change without notice.

 

 

WARRANTY

 

 

DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY

     Delta Electronics Inc. (“Delta Electronics”) warrants to the original consumer purchaser in 

the USA that the Breez ventilation fan products will be free from defects in material or 

workmanship. This warranty is limited to three (3) years from the original date of purchase.

Limitations and Exclusions 

1. During the warranty period, a replacement for any defective product will be supplied free 

of charge for installation by the consumer. The warranty provided herein does not cover 

charges for labor or other costs incurred in the troubleshooting, repair, removal, and 

installation service.

2. All returns of defective parts or products must include the product model number, and 

must be made through an authorized Delta Electronics distributor. Authorized returns must 

be shipped prepaid. Repaired or replacement products will be shipped by Delta Electronics 

F.O.B. shipping point.

3. Delta Electronics shall not be liable for any indirect, incidental, consequential, punitive, or 

special damages arising out of or in connection with products use or performance, 

regardless of the form of action whether in contract, tort (including negligence), strict 

product liability or otherwise. 

4. This warranty does not extend to fluorescent lamp starters and tubes.

5. The warranty does not cover if user does not comply with manufacturer’s installation 

manual.

6. To qualify for warranty service, you must notify Delta Electronics at the address or 

telephone number below.

7. Delta Electronics shall have no liability to the original owner-user with respect to any 

defect caused by abuse, misuse, neglect, improper transportation or storage, improper 

testing, improper installation, improper operation, improper use, improper maintenance, 

improper repair, improper alteration, improper modification, tampering or accident of 

products or parts thereof, or unusual deterioration or degradation of products or parts 

thereof due to a physical environment beyond the requirements of products’ specifications.

Address: 4405 Cushing Parkway, Fremont, CA 94538

US Toll Free Number: 1-888-979-9889

Отзывы: