MODELS
SIG80 / SIG80M / SIG110 / SIG110H / SIG110D
Page 4.
Motion Model: SIG80M
5-2. Motion control mode: Turn the POWER switch on to operate at motion
control mode. When motion is detected, the fan will ru n at full speed
and the LED indicator will be amber. When motion is not detected, the
fan will continue to run at the full speed until the user -adjustable time
delay has elapsed, and then will automatically change to the
user-adjustable low speed airflow. The LED indicator will be green.
Factory setting: low speed airflow 40CFM, time delay 15 minutes.
Humidity Model: SIG110H
5-3. Humidity control mode: Turn the POWER switch on to operate at
humidity control mode - the LED indicator will be blue. When the
ambient humidity is higher than the user -adjustable set -point, the fan
will run at full speed. When the ambient humidity is lower than the
set-point, the fan will continue to run at the full speed until a 10-
minute time delay has elapsed, and then will auto matically change to
the user-adjustable low speed airflow.
5-4. Full speed mode: Turn the MODE switch on to operate at full speed
mode - the LED indicator will be amber.
5-5. Humidity tolerance is about ±10%. Long -time operation will influence
the detectin g precision as dust accumulates. The humidity switch may
need to be adjusted.
Factory setting: low speed airflow 60CFM, humidity 60%RH.
Dual Speed Model: SIG110D
5-6. Low speed control mode: Turn the POWER switch on (MODE switch is
off) to operate at the user-adjustable low speed airflow - the LED will
be green.
5-7. Full speed control mode: Turn the POWER switch & MODE switch on to
operate at full speed mode - the LED indicator will be amber. When the
user turns the MODE switch off, the fan will continue to run at the full
speed until the user -adjustable time delay has elapsed, and then will
automatically change to the user -adjustable low speed airflow. The
LED indicator will be green.
Factory setting: low speed airflow 60CFM, time delay 15 minutes.
MAINTENANCE WARNING:
Disconnect the power source before working on the unit. Routine
maintenance must be done every year.
CAUTION:
1.
Never use gasoline, benzene, thinner or any other such chemicals to
clean the ventilating fan.
2.
Do not allow water to enter the mot or.
3.
Do not soak resin parts in water over 60°C (140°F).
CLEANING
1.
Pull down the springs to remove the grille.
2.
Wash and clean the grille. (Use non -abrasive kitchen detergent and
wipe dry with a new cloth.)
3.
Remove dust and dirt from the ventilating fan.
4.
Using a cloth dampened with non -abrasive kitchen detergent, remove
any dirt from ventilating fan. Wipe dry with a new cloth.
5.
Replace the grille.
DIMENSION
SPECIFICATIONS
Model No.
Voltage
(V)
Frequency
(Hz)
Power
@ 0.1”SP
(W)
Air Flow
@ 0.1”SP
(CFM)
Weight
(lb.)
Power
(W)
Note
SIG80
120
60
8.2
80
10
18.0
Single Speed
SIG80M
120
60
8.2
80
10
18.0
Motion Sensor
SIG110
120
60
12.7
110
10
23.0
Single Speed
SIG110H
120
60
12.7
110
10
23.0
Humidity
Sensor
SIG110D
120
60
12.7
110
10
23.0
Dual Speed
Note: Design and specifications subject to change without notice.
WARRANTY
DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY
Delta Electronics Inc. (“Delta Electronics”) warrants to the original consumer purchaser in
the USA that the Breez ventilation fan products will be free from defects in material or
workmanship. This warranty is limited to three (3) years from the original date of purchase.
Limitations and Exclusions
1. During the warranty period, a replacement for any defective product will be supplied free
of charge for installation by the consumer. The warranty provided herein does not cover
charges for labor or other costs incurred in the troubleshooting, repair, removal, and
installation service.
2. All returns of defective parts or products must include the product model number, and
must be made through an authorized Delta Electronics distributor. Authorized returns must
be shipped prepaid. Repaired or replacement products will be shipped by Delta Electronics
F.O.B. shipping point.
3. Delta Electronics shall not be liable for any indirect, incidental, consequential, punitive, or
special damages arising out of or in connection with products use or performance,
regardless of the form of action whether in contract, tort (including negligence), strict
product liability or otherwise.
4. This warranty does not extend to fluorescent lamp starters and tubes.
5. The warranty does not cover if user does not comply with manufacturer’s installation
manual.
6. To qualify for warranty service, you must notify Delta Electronics at the address or
telephone number below.
7. Delta Electronics shall have no liability to the original owner-user with respect to any
defect caused by abuse, misuse, neglect, improper transportation or storage, improper
testing, improper installation, improper operation, improper use, improper maintenance,
improper repair, improper alteration, improper modification, tampering or accident of
products or parts thereof, or unusual deterioration or degradation of products or parts
thereof due to a physical environment beyond the requirements of products’ specifications.
Address: 4405 Cushing Parkway, Fremont, CA 94538