background image

3

ADDITIONAL SAFETY RULES

FOR AIR CLEANERS

1.

DANGER: DO NOT USE THIS UNIT TO FILTER METAL DUST.

Combining wood and metal dust can create

an explosion or fire hazard. This unit is intended to filter non-explosive atmospheres only.

2.

WARNING: DUST GENERATED BY CERTAIN WOODS AND WOOD PRODUCTS CAN BE HAZARDOUS TO

YOUR HEALTH.

3.

WARNING: DO NOT USE THIS UNIT TO DISSIPATE FUMES OR SMOKE

.

This air cleaner is intended for use

where only dry airborne dust is present. Its use should be limited to non-explosive, non-metallic atmospheres.

4

. DO NOT OPERATE THIS UNIT UNTIL IT IS COMPLETELY ASSEMBLED AND INSTALLED ACCORDING TO

THE INSTRUCTIONS

.

5.

OBTAIN ADVICE FROM YOUR SUPERVISOR, INSTRUCTOR, OR ANOTHER QUALIFIED PERSON 

if you are

not thoroughly familiar with the operation of this unit.

6.

FOLLOW ALL WIRING CODES

and recommended electrical connections.

7.

DO NOT LIFT THIS UNIT BY THE POWER CORD. 

Do not use the power cord as a hanging device.

8.

SECURELY ANCHOR THIS UNIT INTO A SUPPORTING STRUCTURE 

when suspending it from the ceiling.

Always keep a minimum of 7 feet between the bottom of the unit and the floor surface to allow for sufficient head
clearance. Use only a chain rated for a minimum of 150 lb. working load to adequately hold the unit. Use steel S-
Hooks that are at least 1/4" in diameter to suspend the unit from the ceiling. Lag-type bolts used suspend the unit
from the ceiling must be threaded at least 1-1/2" into supporting structural members.

9.

SUPPORT THIS UNIT OR SECURELY CLAMP IT TO THE WORK SURFACE WHEN IT IS USED IN A PORTABLE
APPLICATION

to eliminate potential movement and/or damage from falling.

10.

ENSURE THAT THE INTAKE AND EXHAUST AREAS ARE CLEAR PRIOR TO STARTING THE UNIT.

11.

KEEP ARMS, HANDS, AND FINGERS AWAY FROM THE FAN. 

Avoid all exposure to rotating parts.

12.

DO NOT OPERATE THIS UNIT WITHOUT THE FILTERS IN PLACE.

13.

DO NOT ATTEMPT TO REMOVE OR REPLACE THE FILTER(S) WHILE THE UNIT IS RUNNING.

Make certain

that the unit is disconnected from the power source.

14.

MAINTAIN THE UNIT IN TOP CONDITION

. Keep filters clean for optimum performance. Follow all instructions for

changing and cleaning filters.

15.

STORE THIS UNIT IN A LOCATION

that eliminates the potential of damage to the power cord. Safely store power

cord on the unit to eliminate tripping hazards.

16

. TURN THE UNIT “OFF” AND DISCONNECT IT FROM THE POWER SOURCE

before installing or removing

accessories, or when making repairs.

SAVE THESE INSTRUCTIONS

.

Refer to them often

and use them to instruct others

.

Содержание ShopMaster AP200

Страница 1: ...906565 07 18 02 Copyright 2002 Delta Machinery ESPA OL P GINA 13 To learn more about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance please...

Страница 2: ...with padlocks master switches or by removing starter keys 9 DON T FORCE TOOL It will do the job better and be safer at the rate for which it was designed 10 USE RIGHT TOOL Don t force tool or attachme...

Страница 3: ...arance Use only a chain rated for a minimum of 150 lb working load to adequately hold the unit Use steel S Hooks that are at least 1 4 in diameter to suspend the unit from the ceiling Lag type bolts u...

Страница 4: ...pter should be used only until a properly grounded outlet can be installed by a qualified electrician The green colored rigid ear lug and the like extending from the adapter must be connected to a per...

Страница 5: ...ll make for a cleaner and safer environment This Air Cleaner will filter the air in a room measuring 20 x 20 x 8 sixteen times an hour If desired multiple units can be used to filter larger areas UNPA...

Страница 6: ...6 AIR CLEANER PARTS Fig 2 1 Air cleaner 2 Four 5 16 18x1 eye bolts 3 Four 5 16 18 flange nuts 4 Four rubber feet 1 2 3 4...

Страница 7: ...er or near any heating or cooling vents USING THE AIR CLEANER ON A BENCH OR FLOOR SURFACE 1 Locate 4 self adhesive rubber feet D Fig 2 supplied with the unit Carefully place Air Cleaner on a firm supp...

Страница 8: ...readed at least eight complete turns into tapped hole in air cleaner Make certain the flange nuts E Fig 5 are tightened down against the surface of the air cleaner after height adjustments are made Wh...

Страница 9: ...ght odor for the first couple hours of operation due to the protective coating which is applied to internal components This odor will dissipate and should be disregarded IMPORTANT Never operate the ai...

Страница 10: ...suspending the air cleaner from the ceiling or other overhead support make certain the supporting hardware not supplied is securely anchored into a wooden supporting structure as shown in Fig 17 WARN...

Страница 11: ...S S E D A I R C A N B E DANGEROUS FOR OPERATOR SAFETY DO NOT EXCEED AN AIR PRESSURE OF 30 PSI OR POINT AIR NOZZLE TOWARD ANYONE OR AIM AIR NOZZLE AT YOUR OWN BODY ALWAYS WEAR SAFETY GLASSES AND DUST...

Страница 12: ...s sole warranty and sets forth the customer s exclusive remedy with respect to defective products all other warranties express or implied whether of merchantability fitness for purpose or otherwise a...