background image

Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension cord which
has a 3-prong grounding type plug and matching receptacle which will accept the machine’s plug. When using an
extension cord, be sure to use one heavy enough to carry the current of the machine. An undersized cord will cause
a drop in line voltage, resulting in loss of power and overheating. Fig. D, shows the correct gauge to use depending
on the cord length. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.

EXTENSION CORDS

OPERATING INSTRUCTIONS

FOREWORD

The Delta ShopMaster Model AP200 Air Cleaner is specifically designed to quietly circulate and filter non-metallic dust
which is generated throughout the work area. The Air Cleaner is furnished with two filters: a disposable outer filter which
filters out 98% of particles five microns in size; and the secondary filter will capture 85% of dust particles of one micron
in size (one micron = one millionth of a meter). Breathing microscopic particles can be a potential health hazard;
therefore, filtering out microscopic dust particles of the mentioned sizes will make for a cleaner and safer environment.
This Air Cleaner will filter the air in a room measuring 20’ x 20’ x 8’ sixteen times an hour. If desired, multiple units can
be used to filter larger areas. 

UNPACKING AND CLEANING

Carefully unpack the machine and all loose items from the shipping container(s). Remove the protective coating from
all unpainted surfaces. This coating may be removed with a soft cloth moistened with kerosene (do not use acetone,
gasoline or lacquer thinner for this purpose). After cleaning, cover the unpainted surfaces with a good quality household
floor paste wax.

NOTICE: THE MANUAL COVER PHOTO ILLUSTRATES THE CURRENT

PRODUCTION MODEL.  ALL OTHER ILLUSTRATIONS ARE REPRESENTATIVE

ONLY AND MAY NOT DEPICT THE ACTUAL COLOR, LABELING OR

ACCESSORIES AND MAY BE INTENDED TO ILLUSTRATE TECHNIQUE ONLY.

5

Fig. D

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES

Ampere

Total Length

Gauge of

Rating

Volts

of Cord in Feet

Extension Cord

0-6

115

up to 25

18 AWG

0-6

115

25-50

16 AWG

0-6

115

50-100

16 AWG

0-6

115

100-150

14 AWG

6-10

115

up to 25

18 AWG

6-10

115

25-50

16 AWG

6-10

115

50-100

14 AWG

6-10

115

100-150

12 AWG      

10-12

115

up to 25

16 AWG

10-12

115

25-50

16 AWG

10-12

115

50-100

14 AWG

10-12

115

100-150

12 AWG

12-16

115

up to 25

14 AWG

12-16

115

25-50

12 AWG

12-16

115

GREATER THAN 50 FEET NOT RECOMMENDED

Содержание ShopMaster AP200

Страница 1: ...906565 07 18 02 Copyright 2002 Delta Machinery ESPA OL P GINA 13 To learn more about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance please...

Страница 2: ...with padlocks master switches or by removing starter keys 9 DON T FORCE TOOL It will do the job better and be safer at the rate for which it was designed 10 USE RIGHT TOOL Don t force tool or attachme...

Страница 3: ...arance Use only a chain rated for a minimum of 150 lb working load to adequately hold the unit Use steel S Hooks that are at least 1 4 in diameter to suspend the unit from the ceiling Lag type bolts u...

Страница 4: ...pter should be used only until a properly grounded outlet can be installed by a qualified electrician The green colored rigid ear lug and the like extending from the adapter must be connected to a per...

Страница 5: ...ll make for a cleaner and safer environment This Air Cleaner will filter the air in a room measuring 20 x 20 x 8 sixteen times an hour If desired multiple units can be used to filter larger areas UNPA...

Страница 6: ...6 AIR CLEANER PARTS Fig 2 1 Air cleaner 2 Four 5 16 18x1 eye bolts 3 Four 5 16 18 flange nuts 4 Four rubber feet 1 2 3 4...

Страница 7: ...er or near any heating or cooling vents USING THE AIR CLEANER ON A BENCH OR FLOOR SURFACE 1 Locate 4 self adhesive rubber feet D Fig 2 supplied with the unit Carefully place Air Cleaner on a firm supp...

Страница 8: ...readed at least eight complete turns into tapped hole in air cleaner Make certain the flange nuts E Fig 5 are tightened down against the surface of the air cleaner after height adjustments are made Wh...

Страница 9: ...ght odor for the first couple hours of operation due to the protective coating which is applied to internal components This odor will dissipate and should be disregarded IMPORTANT Never operate the ai...

Страница 10: ...suspending the air cleaner from the ceiling or other overhead support make certain the supporting hardware not supplied is securely anchored into a wooden supporting structure as shown in Fig 17 WARN...

Страница 11: ...S S E D A I R C A N B E DANGEROUS FOR OPERATOR SAFETY DO NOT EXCEED AN AIR PRESSURE OF 30 PSI OR POINT AIR NOZZLE TOWARD ANYONE OR AIM AIR NOZZLE AT YOUR OWN BODY ALWAYS WEAR SAFETY GLASSES AND DUST...

Страница 12: ...s sole warranty and sets forth the customer s exclusive remedy with respect to defective products all other warranties express or implied whether of merchantability fitness for purpose or otherwise a...

Отзывы: