Specifications and Product Interface R1-EC5614 User Guide
2-2
2
2.1 Electrical specifications
Item
Description
Standard number of
controlled axis (maximum)
4 axes (6 axes)
Module control power
Supplied by E-Bus
Magnification selection
X1 / X10 / X100
Jog input
3 sets
Sampling frequency
40 kHz
External I/O power supply
24 V
DC
(-15% to +20%)
FIFO length
30 sets
Communication time
500 μ
s - 3276800
μ
s
Active level (On > Off)
< 8 V
DC
Active level (Off > On)
> 16.5 V
DC
E-Bus current consumption
180 mA
Electrical isolation
500 Vrms (E-Bus / signal voltage)
Weight
55 g (0.12 lb)
Operating environment
Operating temperature: 0°C to 50°C (32°F to 122°F)
Storage temperature: -20°C to +70°C (-4°F to +158°F)
Mounting type
Rail type
Vibration resistance /
shock resistance
Conforms to EN 60068-2-6 / EN 60068-2-27 / 29
Electromagnetic compatibility /
noise immunity
ESD (IEC 61131-2, IEC 61000-4-2)
EFT (IEC 61131-2, IEC 61000-4-4)
RS (IEC 61131-2, IEC 61000-4-3)
Protection level
IP20
Certification
Содержание R1-EC5614