I
NSTALLATION
G
UIDE
48
I
NSTALLATION
S
ETTINGS
Table 5-4: Grid Setting Parameters
Parameter
Description
Vac High Off
Inverter will be disconnected from grid if the phase voltage of AC rises to
this value.
Vac High On
Inverter will be reconnected to grid if the phase voltage of AC drops to this
value.
Vac High Off T
If AC voltage reaches to the value of Vac High Off, inverter will be
disconnected in this time.
Vac Low Off
Inverter will be disconnected from grid if the phase voltage of AC drops to
this value.
Vac Low On
Inverter will be reconnected to grid if the phase voltage of AC rises to this
value.
Vac Low Off T
If AC voltage reaches to the value of Vac Low Off, inverter will be
disconnected in this time.
Vac High Off Slow
The function is same as Vac High Off, but the value must be lower than
former.
Vac High On Slow
The function is same as Vac High On, but the value must be lower than
former.
Vac High Off Slow T
The function is same as Vac High Off T, but the time must be longer than
former.
Vac Low Off Slow
The function is same as Vac Low Off, but the value must be higher than
former.
Vac Low On Slow
The function is same as Vac Low On, but the value must be higher than
former.
Vac Low Off Slow T
The function is same as Vac High Off T, but the time must be longer than
former.
Fac High Off
Inverter will be disconnected from grid if AC frequency rises to this value.
Fac High On
Inverter will be reconnected to grid if AC frequency drops to this value.
Fac High Off T
If AC frequency reaches to the value of Fac High Off, inverter will be
disconnected in this time.
Fac Low Off
Inverter will be disconnected from if AC frequency drops to this value.
Fac Low On
Inverter will be reconnected to grid if AC frequency rises to this value.
Fac Low Off T
If AC frequency reaches to the value of Fac Low Off, inverter will be
disconnected in this time.
Fac High Off Slow
The function is same as Fac High Off, but the value must be lower than
former.
Fac High On Slow
The function is same as Fac High On, but the value must be lower than
former.
Fac High Off Slow T
The function is same as Fac High Off T, but the time must be longer than
former.
Содержание PhotoVoltaic RPI-C500
Страница 1: ...PhotoVoltaic Inverter RPI C500 PV Inverter ...
Страница 26: ...INSTALLATION GUIDE 20 INSTALLATION DC CONNECTION Figure 5 4 Dimensions of the DC connection lugs ...
Страница 31: ...INSTALLATION GUIDE 25 INSTALLATION AC CONNECTION Figure 5 9 Dimensions of the AC connection lugs ...
Страница 88: ...INSTALLATION GUIDE 82 ...
Страница 89: ...光伏逆变器 RPI C500 光伏逆变器 ...
Страница 100: ...安装手册 5 产品外观 外部三角视图 3 2 2 外部三角视图 图 3 2 外部后视图 进气孔 ...
Страница 107: ...安装手册 13 运输和安装准备 使用起重机 搬运时不含包装纸箱和栈板 1 将逆变器前门和后门打开 2 松开上盖的螺丝 图 4 9 松开上盖的螺丝 3 拆掉逆变器的上盖 图 4 10 拆掉逆变器上盖 ...
Страница 114: ...安装手册 20 安装说明 DC 端连接 图 5 4 DC 端连接端尺寸图 ...
Страница 116: ...安装手册 22 安装说明 AC 端连接 5 3 AC 端连接 1 如图 5 6 所示将连接到 AC 端的电缆穿过底板 图 5 6 AC 端配线 ...
Страница 119: ...安装手册 25 安装说明 AC 端连接 图 5 9 AC 端连接端尺寸图 ...
Страница 156: ...安装手册 62 维修保养 更换风扇模块 7 维修保养 7 1 更换风扇模块 1 按拉且扭转把手 之后打开后门 图 7 1 按拉扭转把手 ...
Страница 157: ...安装手册 63 维修保养 更换风扇模块 2 将需置换的风扇模块上的电源接头拔除 图 7 2 拔除电源接头 3 松开锁附在下风扇与机壳上的螺丝和螺帽 然后将下风扇移除 图 7 3 松开下风扇的螺丝和螺帽 ...
Страница 158: ...安装手册 64 维修保养 更换风扇模块 4 松开锁附在上风扇与机壳上的螺丝 然后将上风扇移除 图 7 4 松开上风扇的螺丝 ...
Страница 159: ...安装手册 65 维修保养 更换进气口滤网 7 2 更换进气口滤网 1 按拉且扭转把手 之后打开后门 图 7 5 按拉扭转把手 2 松开锁附在滤网盖与后门上的螺丝 之后打开滤网盖 图 7 6 松开滤网盖上的螺丝 ...
Страница 160: ...安装手册 66 维修保养 更换进气口滤网 3 松开锁附在滤网上的螺丝 图 7 7 松开滤网的螺丝 4 取出滤网 图 7 8 取出滤网 ...
Страница 161: ...安装手册 67 维修保养 清理排气孔滤网 7 3 清理排气孔滤网 1 将逆变器前门打开 2 松开排气孔滤网挡板上的螺帽 图 7 9 松开排气孔滤网的螺帽 3 把排气孔滤网挡板向右移动 图 7 10 将挡板向右移动 ...
Страница 162: ...安装手册 68 维修保养 清理排气孔滤网 4 直接取出挡板和排气孔滤网 图 7 11 取出排气孔滤网 ...
Страница 165: ...安装手册 71 维修保养 更换 SURGE PROTECTION DEVICE 4 退出已损坏的 SPD 并更换新的 Figure 7 15 退出已损坏的 SPD ...
Страница 176: ...Version 01180521 5013209808 ...