background image

LYTE II DIN Rail Power Supply 

DRL-480W series / DRL-

V480W1EN

 

PRELIMINARY DATASHEET- For product review purpose only. The specs are subjected to change.

 

 

 

 

 

  

All parameters are specified at 25°C ambient and AC input unless otherwise indicated.

 

  www.DeltaPSU.com (August 2021, Rev. X00) 

 

1

 

 

 

Highlights & Features 

  Universal AC input voltage range 

  Built-in constant current circuit for reactive loads 

  High power density 

  Operate from -30°C to +70°C with -40°C Cold Start 

  Slim type design 

  Lower no load power consumption  

  Compliance with DOE VI Energy Standard  

  Compliance to SEMI F47 @ 200 Vac   

 

Safety Standards 

TBD 
CB Certified for worldwide use 

 

 

Model Number:

   

DRL-

V480W1E

 

Unit Weight:

 

 

0.87 kg (1.91 lb)

 

Dimensions (L x W x D):

  123.6 x 56 x 116.8 mm 

(4.87 x 1.97 x 4.60 inch) 

 

General Description

 

Delta’s LYTE II DIN rail power supply series is designed for cost sensitive users who need to fulfill essential features needed for many 

general industrial applications, without compromising on quality and reliability. The convection-cooled LYTE II series will operate between  

-30°C to +70°C, with full rated power available from -30°C to +50°C at 230 Vac. The overcurrent protection is designed to operate in 

constant current mode, which makes the LYTE II series suitable for inductive and capacitive load applications. The product is certified 

according to safety standards IEC/EN/UL 62368-1. Electromagnetic radiated and conducted emissions are compliant to heavy industrial 

EN 61000-6-4 Class B Emission standard and EN 61000-6-2 Immunity standard; and, the product is fully compliant for environmental 

protection requirements per RoHS Directive. 

 

 

Model Information 

LYTE II DIN Rail Power Supply 

 

Model  Number

 

Input Voltage Range

 

Rated Output  Voltage

 

Rated Output  Current

 

DRL-24V480W1EN

 

90-264 Vac 

24 Vdc 

20.0 A 

DRL-48V480W1EN 

48 Vdc 

10.0 A 

 

 

Model Numbering 

DR

 

L –

 

V

 

480W

 

1

 

E

 

N

 

 

DIN Rail  Product Type 

L – LYTE Family 

Output Voltage 
24 – 24 V 

48 – 48 V 

 

Output 

Power 

Single Phase  LYTE II Series 

with Slim Design 

N – No DC OK 

Relay Contact 

Blank – No coating  
A – With coating*

1

 

*1: 24 V model only 

 

 

 

Содержание LYTE II DRL-24V480W1EN

Страница 1: ...applications without compromising on quality and reliability The convection cooled LYTE II series will operate between 30 C to 70 C with full rated power available from 30 C to 50 C at 230 Vac The ov...

Страница 2: ...Vac Output Ratings Characteristics 2 Nominal Output Voltage 24 Vdc 48 Vdc Factory Set Point Tolerance 24 Vdc 1 48 Vdc 1 Output Voltage Adjustment Range 24 28 Vdc 48 55 Vdc Output Current 0 20 0 A 0 10...

Страница 3: ...er De rating Temperature 40 C de rate power by 1 67 C 115 Vac 50 C de rate power by 2 5 C 230 Vac Input Voltage 100Vac de rate power by 1 Vac Operating Humidity 20 to 90 RH Non Condensing Operating Al...

Страница 4: ...O P 100 load Ta 25 C Expected Cap Life Time 10 years 230 Vac 50 load 40 C Safety Standards Directives Electrical Safety CB scheme TUV Bauart UL cUL BSMI EAC IEC 62368 1 IEC 60950 1 IEC 61010 1 2 201 E...

Страница 5: ...ectrical Fast Transient Burst IEC 61000 4 4 Level 3 Criteria A1 2 kV Surge IEC 61000 4 5 Level 4 Criteria A1 Common Mode4 4 kV Differential Mode5 2 kV Conducted IEC 61000 4 6 Level 3 Criteria A1 150 k...

Страница 6: ...iagram DRL V480W1EN EMI Filter PFC Converter Inrush current limit Filter DC DC Converter Output Rectifier Filter Over Temperature Protection PWM Control Over Power Protection Photo Coupler Feedback Co...

Страница 7: ...ons L x W x D 123 6 x 56 x 116 8 mm 4 87 x 1 57 x 4 60 inch Unless otherwise specified tolerance of dimension are 0 5 mm AWG Wire Table Current Rating for PVC Wire 6 AWG 52 5 A 8 AWG 37 5 A 10 AWG 29...

Страница 8: ...e output capacity is not reduced when the surrounding air temperature 50 C the device will run into Over Temperature Protection When activated power supply will latch off until the surrounding air tem...

Страница 9: ...l out the power supply unit PSU from the rail Safety Instructions Vertical Mounting ALWAYS switch mains of input power OFF before connecting and disconnecting the input voltage to the unit If mains ar...

Страница 10: ...d for the output voltage to change from 10 to 90 of its final steady state set value Hold up Time Time between the collapse of the AC input voltage and the output falling to 95 of its steady state set...

Страница 11: ...lso provides protection against short circuits When a short circuit is applied the output current will operate in Hiccup mode The power supply will return to normal operation after the short circuit i...

Страница 12: ...no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets Customer shall take its responsibility for evaluation of using the produc...

Отзывы: