6
Model:
ITG70LED / VFB070B4LED1
ASSEMBLY INSTRUCTIONS
6. Install a circular 4 in. duct (not included) and secure
it with duct tape or clamps (neither included). Finish
ceiling work. The ceiling hole should be aligned with
the edge of the Fan Body
❶
.
Turn off power source. Review all safety precautions.
1. Remove existing fan.
2. Measure the opening to ensure it is large enough to
accommodate the new Fan Body(7 1/2in. x 7 1/4in.).
Note: 7 1/4 inch side of opening should be flush with
the joist.
3. If this fan is not replacing an old fan, be sure to cut
a 7 1/2in. x 7 1/4in. opening for the Fan Body
❶
.
Make sure the 7 1/4 inch side of opening is flush
with the joist for installation from below.
4. Attach the Duct Connector
❸
to the Fan Body
❶
.
Ceiling
4 in. Duct
Duct tape
or clamp
1
6
1
2
9.4"
9.4"
7 1/ 2 in.
7 1/4 in.
3
1
1
1
1
1
3
4
EXISTING CONSTRUCTION