manualshive.com logo in svg
background image

Operating and Installation
Instructions
Ventilation Hood

To prevent accidents and damage to the appliance, you 

must

 read

these instructions before installing the appliance and using it for the
first time.

en-US

M.-Nr. 12 039 220

Содержание DAS 8930

Страница 1: ...nd Installation Instructions Ventilation Hood To prevent accidents and damage to the appliance you must read these instructions before installing the appliance and using it for the first time en US M Nr 12 039 220 ...

Страница 2: ...e cooktop lighting on off 23 Safety shut off 23 Changing settings 24 Adjusting the grease filter filter saturation indicator 24 Adjusting or deactivating the filter saturation indicator for the charcoal filter 25 Deactivating power management 25 Audible signal for the sensor controls 26 Energy saving tips 27 Cleaning and care 28 Stainless steel housing 28 Important information for appliances with ...

Страница 3: ...s 34 Installation materials for recirculation mode 35 Further installation materials 35 Appliance dimensions 36 Distance between cooktop and ventilation hood S 37 Adjusting the deflector plate 38 Air venting 38 Non return flap 39 Condensate 39 Reducing Collar 40 Electrical connection 40 Technical data 42 Optional accessories for recirculation mode 42 ...

Страница 4: ...losive Materials And Vapors This appliance is intended for residential use only Use only as described in these operating instructions This ventilation hood is not intended for outdoor use It must only be used to extract and clean vapors produced during cooking Any other use occurs at the owner s own risk Where a recirculation ventilation hood is installed above a gas cooktop please check that all ...

Страница 5: ...be allowed to clean or service the hood Please supervise children in the vicinity of the hood and do not let them play with it The LED ClearView lighting is very intense Avoid looking directly into the light for prolonged periods of time Danger of suffocation Ensure that any plastic wrappings bags etc are disposed of safely and kept out of the reach of children ...

Страница 6: ...installation instructions Contact Miele s Technical Service Department for examination repair or adjustment Repairs and other work by unauthorized persons could be dangerous and may void the warranty A damaged ventilation hood can be dangerous Always check for visible signs of damage Never use a damaged ventilation hood Be certain your appliance is properly installed and grounded by a qualified te...

Страница 7: ...in the Cleaning and care section of this manual Under no circumstances should any other parts of the housing be opened Tampering with electrical connections or components and mechanical parts is highly dangerous to the user and can cause operation faults If the power cord is damaged it must only be replaced by a qualified service technician During installation maintenance and repair work the venti...

Страница 8: ...en switched on the ventilation hood could draw flames into the filter Fat deposits could ignite presenting a fire hazard WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE ...

Страница 9: ...n the ventilation hood on whenever a burner is in use to prevent damage from condensation Overheated oil and fat can ignite causing fire damage to the ventilation hood Do not leave cookware pans and deep fat fryers unattended when cooking with oil or fat Similarly never leave an open flame unattended when grilling Fat and debris deposits impair the proper functioning of the ventilation hood To ens...

Страница 10: ...g do not damage electrical wiring and other hidden utilities d Ducted hoods must always be vented to the outdoors e Do not use this hood with any solid state speed control device To determine whether a ventilation hood may be operated above your cooking appliance please refer to the information provided by the appliance s manufacturer Safety regulations prohibit the installation of a ventilation h...

Страница 11: ...cting duct material Exhaust air should not be vented into a chimney or vent flue which is otherwise in use and should not be channeled into ducting which ventilates rooms with fuel burning installations If exhaust air is to be extracted into a chimney or ventilation duct no longer used for other purposes seek professional advice WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK Cleaning a...

Страница 12: ...e used the warranty may become void Defective components should be replaced by Miele original parts only Only with these parts can safety of the appliance be assured as intended by the manufacturer Miele will guarantee to supply functional parts for a minimum of 10 years and up to 15 years following the discontinuation of your ventilation unit ...

Страница 13: ...or the proper functioning and safe use of the equipment Handling these materials improperly by disposing of them in your household waste can be harmful to your health and the environment Therefore please do not dispose of your old appliance with regular household waste and follow local regulations on proper disposal Consult with local authorities dealers or Miele in order to dispose of and recycle...

Страница 14: ...Guide to the ventilation hood 14 ...

Страница 15: ...od on and off h Sensor controls for switching the blower on and off and for setting the blower power level i Sensor control for the delayed shutdown function j Sensor control for the grease filter saturation indicator k Sensor control for the charcoal filter saturation indicator l Sensor control for switching the lighting on and off and for dimming the lighting m Sensor controls for selecting and ...

Страница 16: ... the grease filters and directed outside Recirculation mode Recirculation mode hoods require a recirculation kit and OdorFree Charcoal Filters available as optional accessories see Technical Data for more information The air is drawn in and cleaned first by the grease filters and then by the charcoal filters The clean air is then recirculated back into the kitchen ...

Страница 17: ...ch the charcoal filter symbol The charcoal filter symbol and one of the blower power level indicators will flash Touch the B control Confirm your choice by touching the charcoal filter control All the indicator lights will go out Vented mode has now been set If the selection is not confirmed within 4 minutes the system will revert to the previous setting Setting up Miele home Required a WiFi netwo...

Страница 18: ... via the app The Miele app can be used to connect to your network Install the Miele app on your mobile device To log in you will need 1 your WiFi network password 2 your ventilation hood password The password for your ventilation hood consists of the last 9 digits of the serial number This can be found on the appliance s data tag The data plate is located on the housing of the ventilation hood and...

Страница 19: ... delayed shutdown control The ventilation hood can now be operated via the app Connecting via WPS Your WiFi router must support WPS WiFi Protected Setup Touch the On Off switch All symbols light up with reduced brightness Press and hold the delayed shutdown control until the grease filter and charcoal filter symbols light up Touch the 2 control 2 will light up constantly 3 will flash on and off Th...

Страница 20: ...ugh Repeat the steps above Tip If your WiFi router does not support WPS please connect via the Miele app Signing out of WiFi reset to factory settings To set up a new WiFi connection the existing WiFi connection must be disconnected Touch the On Off switch All symbols light up with reduced brightness Press and hold the delayed shutdown control until the grease filter and charcoal filter symbols li...

Страница 21: ...3 will flash on and off After a few seconds 2 and 3 will flash on and off The connection has now been disconnected Exit disconnection mode on the ventilation hood by touching the delayed shutdown control The WiFi connection has now been disconnected A new connection can now be set up ...

Страница 22: ...duced when cooking e g during searing select the B booster level Select the power level required by tapping a button from 1 to B Selecting the second booster level When you select the booster level the B symbol lights up To increase the power level further touch B again The B symbol lights up The second booster level is activated The air throughput is increased for a short time Switching back the ...

Страница 23: ...witches the blower off The blower also switches off if you push the deflector plate in Dimming switching the cooktop lighting on off You can switch the cooktop lighting on by pulling the deflector plate out and off by pushing it in When the deflector plate is pulled out you can switch the cooktop lighting on and off with the lighting control The lighting will switch on at maximum brightness All 3 ...

Страница 24: ...om hardening and making cleaning more difficult Select a longer cleaning interval of 40 or 50 hours if the customer uses very little fat when cooking Touch the On Off switch All symbols light up with reduced brightness Press and hold the delayed shutdown control until the grease filter and charcoal filter symbols light up Touch the grease filter symbol The grease filter symbol and one of the blowe...

Страница 25: ... touching the charcoal filter control If the selection is not confirmed within 4 minutes the system will revert to the previous setting Deactivating power management Keep in mind that this may increase energy consumption Activating deactivating power management Touch the On Off switch All symbols light up with reduced brightness Press and hold the delayed shutdown control After a few seconds the g...

Страница 26: ...nal can be switched off Touch the On Off switch All symbols light up with reduced brightness Press and hold the delayed shutdown control until the grease filter and charcoal filter symbols light up Touch the B control The audible signal is switched off If you want to switch the audible signal on again proceed in the same way Regardless of the previous setting the audible signal will be reactivated...

Страница 27: ...wer hood power level and therefore benefit from reduced energy consumption Check the power level selected on the hood A lower power level is generally sufficient for the majority of cooking Only use the booster level when necessary When a large volume of cooking vapors are being produced switch to a high power level in good time This is more efficient than operating the hood for longer to try to c...

Страница 28: ...the following Cleaners containing soda acid or chloride or cleaners containing solvents Abrasive cleaners such as scouring powder scouring liquid abrasive sponges such as pot scourers or used sponges that still contain residues from abrasive cleaners Important information for appliances with stainless steel surfaces Stainless steel surfaces can be cleaned with a non abrasive cleaning agent designe...

Страница 29: ...be cleaned every 3 to 4 weeks The filter saturation indicator reminds you to regularly clean the grease filters by illuminating the grease filter symbol Removing the grease filters When handling the grease filter be careful not to drop it This can result in damage to the filter and the cooktop below Make sure you hold the filter securely at all times when handling it Remove the grease filters from...

Страница 30: ...to dry When removing the filters for cleaning also clean off any accessible oil or fat buildup from the housing Doing so will prevent a fire hazard Refit the grease filters Resetting the filter saturation indicator for the grease filter Once cleaning is complete the filter saturation indicator must be reset While the blower is turned on touch the grease filter control for approx 3 seconds until on...

Страница 31: ...packaging Insert the charcoal filters into the slots as far as they will go Replace the lid When to change the OdorFree Charcoal Filter Replace the charcoal filters when they no longer absorb kitchen odors effectively and at least every 6 months The filter saturation indicator reminds you to regularly replace the charcoal filters by illuminating the charcoal filter symbol Resetting the filter satu...

Страница 32: ...ood They can be used several times after being reactivated in the oven Please follow the operating instructions supplied with the filters Open the tab using a tool such as a screwdriver Take hold of the tab to pull the charcoal filter out Insert the charcoal filters into the slots as far as they will go Replace the lid ...

Страница 33: ...Please quote the model identifier and serial number of your appliance SN when contacting Miele Customer Service Both pieces of information can be found on the data plate Location of the data plate The data plate is located on the housing of the ventilation hood and is visible when the cover for the charcoal filters is removed Appliance warranty and product registration You can register your produc...

Страница 34: ...ably it should be narrower for better extraction The mounting area must be easily accessible The ventilation hood should be easy to reach and disassemble in case a service call is necessary This should be taken into consideration when planning the position of cabinetry shelves ceilings or decorative elements in the vicinity of the ventilation hood Installation materials 1 non return flap for fitti...

Страница 35: ...tallation kit contains a directional unit socket hose and hose clips DUU 150 for the top of the cabinet or DUU 151 for the sides or front of the cabinet Further installation materials optional accessories DASL 38 trims You will need the trims if you wish to replace an appliance from the DA 35xx or DA 36xx series with this ventilation hood and you want to keep using the existing cabinet The trims a...

Страница 36: ...for cabinets with sides that are between and 16 and 19 mm thick b The ducting can also be connected at the back c Cut out for vented mode or recirculation mode with DUU 150 conversion kit d The upper cabinet can be fitted with a partition after installation Slots for the grease filters and charcoal filters for recirculation mode must remain accessible ...

Страница 37: ...on Miele appliance Electric Cooktops 24 610 mm Electric Barbeques and Fryers 26 660 mm Multiburner Gas Cooktops 43 000 BTU hr 12 6 kW no burner 15 000 BTU hr 4 5 kW 26 660 mm 30 760 mm Multiburner Gas Cooktops 73 800 BTU hr 21 6 kW no burner 16 500 BTU hr 4 8 kW 30 760 mm Multiburner Gas Cooktops 73 800 BTU hr 21 6 kW or one of the burners 16 500 BTU hr 4 8 kW Not possible Single Burner Gas Cookto...

Страница 38: ...k of fire and to properly exhaust air the exhaust gases extracted by the hood should be vented outside of the building only Do not vent exhaust air into spaces within walls or ceilings or in attics crawl spaces or garages To reduce the risk of fire only use metal ductwork Please read and follow the IMPORTANT SAFETY INSTRUCTIONS to reduce the risk of personal injury Follow all local building codes ...

Страница 39: ...e on site vent system does not have a non return flap one is supplied with the ventilation hood The non return flap is installed in the exhaust socket of the fan Condensate If the ducting is to run through cool rooms or ceiling space for example the significant variations in temperature between the different areas can cause condensate to form Insulate the ducting to reduce temperature variations I...

Страница 40: ...lectrical work should be performed by a qualified electrician in strict accordance with national regulations for USA ANSI NFPA 70 and local safety regulations Installation repairs and other work by unqualified persons could be dangerous Ensure that power to the appliance is OFF while installation or repair work is performed Verify that the voltage load and circuit rating information found on the d...

Страница 41: ...ng wire with a grounding plug If there is any doubt have the electrical system of the house checked by a qualified electrician Do not use an extension cord If the power supply cord is too short have a qualified electrician install an outlet near the appliance The plug must be plugged into an outlet that is properly installed and grounded WARNING Grounding instructions Canada The grounding type att...

Страница 42: ...tallation kit DUU 150 or DUU 151 and charcoal filters DKF 31 900 P or DFK 31 R reactivatable must be purchased as optional accessories The packs contain 2 charcoal filters WiFi module EK037 FCC ID 2ACUWEK037 IC 5669C EK037 This device complies with Part 15 of the FCC Rules and with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may ...

Страница 43: ...n contacting Customer Service Canada Importer Miele Limited Headquarters and Miele Centre Customer Support Phone 888 99 MIELE 64353 info mieleusa com 161 Four Valley Drive Vaughan ON L4K 4V8 www miele ca Customer Care Centre Phone customercare miele ca 1 800 565 6435 905 532 2272 International Headquarters Miele Cie KG Carl Miele Straße 29 33332 Gütersloh Germany ...

Страница 44: ...M Nr 12 039 220 00 en US DAS 8930 ...

Отзывы: