6.5.2 Peak cut mode
In this mode, the home load will consume the power from the PV inverter in priority.
When the home load consume more power than the power generated by the inverter,
it will consume the power from the grid. Then, battery will only discharged to the
supply the extra load after the power consume from the grid exceeds the “peak cut
power” setting value. “Peak cut power” can be assigned in the Battery Control page.
Solar Panel
DC
DC
Home Load
Main
Board
Feed-in / Purchase
Consumption
Charge / Discharge
Grid
Light
TV
Refrigerator
Chargeing
CT
H9E
BX6.3_DD
BX6.3_EX
AC
19:00
12:00
07:00
00:00
24:00
PV power
PV power used
for home load consumption
Excess PV power
Home load power usage
Battery discharges
31
Active/Reactive Power Control